메뉴 건너뛰기




Volumn 17, Issue 4, 2004, Pages 272-276

Biomechanical study of lumbar pedicle screws in a corpectomy model assessing significance of screw height

Author keywords

Corpectomy model; Screw height; Stiffness

Indexed keywords

POLYETHYLENE; TITANIUM; ULTRA HIGH MOLECULAR WEIGHT POLYETHYLENE;

EID: 4043123373     PISSN: 15360652     EISSN: None     Source Type: Journal    
DOI: 10.1097/01.bsd.0000095400.27687.89     Document Type: Article
Times cited : (10)

References (12)
  • 1
    • 0025801025 scopus 로고
    • Triangulation of pedicular instrumentation: A biomechanical analysis
    • Ruland CM, McAfee PC, Warden KE et al. Triangulation of pedicular instrumentation: a biomechanical analysis. Spine. 1991; 16(suppl 6): S270-S276.
    • (1991) Spine , vol.16 , Issue.SUPPL. 6
    • Ruland, C.M.1    McAfee, P.C.2    Warden, K.E.3
  • 2
    • 0031837773 scopus 로고    scopus 로고
    • Biomechanical study of lumbar pedicle screws: Does convergence affect axial pullout strength?
    • Barber JW, Boden SD, Ganey T, et al. Biomechanical study of lumbar pedicle screws: does convergence affect axial pullout strength? J Spinal Disord. 1998;11:215-220.
    • (1998) J Spinal Disord , vol.11 , pp. 215-220
    • Barber, J.W.1    Boden, S.D.2    Ganey, T.3
  • 3
    • 0026650483 scopus 로고
    • Instantaneous axis of rotation as a function of the three columns of the spine
    • Haher TR, O'Brien M, Felmly WT, et al. Instantaneous axis of rotation as a function of the three columns of the spine. Spine. 1992;17(suppl 6): S149-S154.
    • (1992) Spine , vol.17 , Issue.SUPPL. 6
    • Haher, T.R.1    O'Brien, M.2    Felmly, W.T.3
  • 5
    • 0027304350 scopus 로고
    • Static and cyclical biomechanical analysis of pedicle screw spinal constructs
    • Cunningham BW, Sefter JC, Shono Y, et al. Static and cyclical biomechanical analysis of pedicle screw spinal constructs. Spine. 1993;18: 1677-1688.
    • (1993) Spine , vol.18 , pp. 1677-1688
    • Cunningham, B.W.1    Sefter, J.C.2    Shono, Y.3
  • 6
    • 0007652535 scopus 로고
    • Improving quality of spinal intemal fixation - Evolution toward "ideal immobilization" - A biomechanical study
    • Gaines RW, Carson WL, Satterlee CC, et al. Improving quality of spinal intemal fixation - evolution toward "ideal immobilization" - a biomechanical study. Orthop. Trans. 1987;11:86-87.
    • (1987) Orthop Trans , vol.11 , pp. 86-87
    • Gaines, R.W.1    Carson, W.L.2    Satterlee, C.C.3
  • 7
    • 0027959952 scopus 로고
    • The effects of pedicle screw fit: An in vitro study
    • Brantley AG, Mayfield JK, Koeneman JB, et al. The effects of pedicle screw fit: an in vitro study. Spine. 1994;19:1752-1758.
    • (1994) Spine , vol.19 , pp. 1752-1758
    • Brantley, A.G.1    Mayfield, J.K.2    Koeneman, J.B.3
  • 8
    • 0027426783 scopus 로고
    • Effect of screw diameter, insertion technique, and bone cement augmentation of pedicular screw fixation strength
    • Wittenberg RH, Lee KS, Shea M, et al. Effect of screw diameter, insertion technique, and bone cement augmentation of pedicular screw fixation strength. Clin Orthop. 1993;296:278-287.
    • (1993) Clin Orthop , vol.296 , pp. 278-287
    • Wittenberg, R.H.1    Lee, K.S.2    Shea, M.3
  • 9
    • 0022628372 scopus 로고
    • A biomechanical study of intrapeduncular screw fixation in the lumbosacral spine
    • Zindrick MR, Wiltse LL, Widell EH, et al. A biomechanical study of intrapeduncular screw fixation in the lumbosacral spine. Clin Orthop. 1986;203:99-112.
    • (1986) Clin Orthop , vol.203 , pp. 99-112
    • Zindrick, M.R.1    Wiltse, L.L.2    Widell, E.H.3
  • 10
    • 0024452327 scopus 로고
    • 1989 Volvo Award in Basic Science. Device related osteoporosis with spinal instrumentation
    • McAFee PC. Farey ID, Sutterlin CE, et al. 1989 Volvo Award in Basic Science. Device related osteoporosis with spinal instrumentation. Spine. 1989;14:919-926.
    • (1989) Spine , vol.14 , pp. 919-926
    • Mcafee, P.C.1    Farey, I.D.2    Sutterlin, C.E.3
  • 11
    • 0031468087 scopus 로고    scopus 로고
    • Clinical outcome after spinal fusion with a rigid versus a semi-rigid pedicle screw system
    • Dahl B, Gehrchen P, Blyme P, et al. Clinical outcome after spinal fusion with a rigid versus a semi-rigid pedicle screw system. Eur Spine J. 1997; 6:412-416.
    • (1997) Eur Spine J , vol.6 , pp. 412-416
    • Dahl, B.1    Gehrchen, P.2    Blyme, P.3
  • 12
    • 0027300763 scopus 로고
    • A prospective, randomized study of lumbar fusion: Preliminary results
    • Zdeblick TA. A prospective, randomized study of lumbar fusion: preliminary results. Spine. 1993;18:983-991.
    • (1993) Spine , vol.18 , pp. 983-991
    • Zdeblick, T.A.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.