Volumn 6, Issue 3, 2004, Pages 709-716

Off-frequency tuning error artifact in steady-state free precession cine imaging due to adjacent air-filled bowel

Author keywords

Air heart interface; Cardiovascular magnetic resonance; Megacolon; Off frequency artifact; Shim; Steady state free precession

Indexed keywords

ADULT; AGED; ARTICLE; ARTIFACT; AWARENESS; CARDIOVASCULAR MAGNETIC RESONANCE; CASE REPORT; CONTROLLED STUDY; DIAGNOSTIC ACCURACY; DIAGNOSTIC ERROR; HEART LEFT VENTRICLE; HEART RIGHT VENTRICLE; HUMAN; IMAGE ANALYSIS; IMAGE PROCESSING; IMAGE QUALITY; IMAGE RECONSTRUCTION; MALE; MEGACOLON; NUCLEAR MAGNETIC RESONANCE IMAGING; PRIORITY JOURNAL; STEADY STATE; STOMACH;

EID: 4043086172     PISSN: 10976647     EISSN: None     Source Type: Journal    
DOI: 10.1081/JCMR-120038089     Document Type: Article
Times cited : (4)

References (11)
  • 2
    • 0035023617 scopus 로고    scopus 로고
    • Cine MR angiography of the heart with segmented true fast imaging with steady-state precession
    • Carr, J. C., Simonetti, O., Bundy, J., Li, D., Pereles, S., Finn, J. P. (2001). Cine MR angiography of the heart with segmented true fast imaging with steady-state precession. Radiology 219:828-834.
    • (2001) Radiology , vol.219 , pp. 828-834
    • Carr, J.C.1    Simonetti, O.2    Bundy, J.3    Li, D.4    Pereles, S.5    Finn, J.P.6
  • 3
    • 0242684663 scopus 로고    scopus 로고
    • Artifact reduction in true-FISP imaging of the coronary arteries by adjusting imaging frequency
    • Deshpande, V. S., Shea, S. M., Li, D. (2003). Artifact reduction in true-FISP imaging of the coronary arteries by adjusting imaging frequency. Magn. Reson. Med. 49:803-809.
    • (2003) Magn. Reson. Med. , vol.49 , pp. 803-809
    • Deshpande, V.S.1    Shea, S.M.2    Li, D.3
  • 4
    • 0023197057 scopus 로고
    • Spatial presaturation: A method for suppression of flow artifacts and improving depiction of vascular anatomy in MR imaging
    • Felmlee, J. P., Ehman, R. L. (1987). Spatial presaturation: a method for suppression of flow artifacts and improving depiction of vascular anatomy in MR imaging. Radiology 164:559-564.
    • (1987) Radiology , vol.164 , pp. 559-564
    • Felmlee, J.P.1    Ehman, R.L.2
  • 5
    • 0035991362 scopus 로고    scopus 로고
    • Fully refocused gradient recalled echo (FRGR) factors affecting flow and motion sensitivity in cardiac MRI
    • Hildebrand, L. B., Buonocore, M. H. (2002). Fully refocused gradient recalled echo (FRGR) factors affecting flow and motion sensitivity in cardiac MRI. J. Cardiovasc. Magn. Reson. 4:211-222.
    • (2002) J. Cardiovasc. Magn. Reson. , vol.4 , pp. 211-222
    • Hildebrand, L.B.1    Buonocore, M.H.2
  • 6
    • 0029658607 scopus 로고    scopus 로고
    • A method to improve the B0 homogeneity of the heart in vivo
    • Jaffer, F. A., Wen, H., Balaban, R. S., Wolff, S. D. (1996). A method to improve the B0 homogeneity of the heart in vivo. Magn. Reson. Med. 36:375-383.
    • (1996) Magn. Reson. Med. , vol.36 , pp. 375-383
    • Jaffer, F.A.1    Wen, H.2    Balaban, R.S.3    Wolff, S.D.4
  • 7
    • 0242385495 scopus 로고    scopus 로고
    • Flow effects in balanced steady state free precessions imaging
    • Markl, M., Alley, M. T., Elkins, C. J., Pelc, N. J. (2003). Flow effects in balanced steady state free precessions imaging. Magn. Resor. Reson. Med. 50:892-903.
    • (2003) Magn. Resor. Reson. Med. , vol.50 , pp. 892-903
    • Markl, M.1    Alley, M.T.2    Elkins, C.J.3    Pelc, N.J.4
  • 9
    • 0028508850 scopus 로고
    • MR imaging instrumentation and image artifacts
    • Patton, J. A. (1994). MR imaging instrumentation and image artifacts. Radiographics 14:1083-1096.
    • (1994) Radiographics , vol.14 , pp. 1083-1096
    • Patton, J.A.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.