메뉴 건너뛰기




Volumn 20, Issue 2, 2004, Pages 276-283

Hydroquinone diphosphate: An alkaline phosphatase substrate that does not produce electrode fouling in electrochemical immunoassays

Author keywords

Electrochemical immunoassay; Electrode fouling; Hydroquinone diphosphate; Voltammetric experiments

Indexed keywords

BIOASSAY; ELECTROCHEMICAL ELECTRODES; ELECTROCHEMICAL SENSORS; HYDROLYSIS; OXIDATION; PASSIVATION; PHOSPHATES; SYNTHESIS (CHEMICAL);

EID: 4043066303     PISSN: 09565663     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.bios.2004.01.013     Document Type: Article
Times cited : (58)

References (25)
  • 1
    • 0027368010 scopus 로고
    • Avidin-biotin based electrochemical immunoassay for thyrotropin
    • Athey D., Ball M., McNeil C.J. Avidin-biotin based electrochemical immunoassay for thyrotropin. Ann. Clin. Biochem. 30:1993;570-577
    • (1993) Ann. Clin. Biochem. , vol.30 , pp. 570-577
    • Athey, D.1    Ball, M.2    McNeil, C.J.3
  • 3
    • 14744305820 scopus 로고
    • Highly sensitive amperometric measurement of alkaline phosphatase activity with glucose oxidase amplification
    • Ciana L.D., Bernacca G., Bordin F., Fenu S., Garetto F. Highly sensitive amperometric measurement of alkaline phosphatase activity with glucose oxidase amplification. J. Electroanal. Chem. 382:1995;129-135
    • (1995) J. Electroanal. Chem. , vol.382 , pp. 129-135
    • Ciana, L.D.1    Bernacca, G.2    Bordin, F.3    Fenu, S.4    Garetto, F.5
  • 4
    • 0343464001 scopus 로고    scopus 로고
    • Electrochemical immunoassay - Zeptomole detection limits
    • Cousino M.A., Heineman W.R., Halsall H.B. Electrochemical immunoassay - zeptomole detection limits. Ann. Chim. 87:1997;93-101
    • (1997) Ann. Chim. , vol.87 , pp. 93-101
    • Cousino, M.A.1    Heineman, W.R.2    Halsall, H.B.3
  • 5
    • 0036861949 scopus 로고    scopus 로고
    • Indirect determination of alkaline phosphatase based on the amperometric detection of indigo carmine at a screen-printed electrode in a flow system
    • Diaz-Gonzalez M., Fernandez-Sanchez C., Costa-Garcia A. Indirect determination of alkaline phosphatase based on the amperometric detection of indigo carmine at a screen-printed electrode in a flow system. Anal. Sci. 18:2002;1209-1213
    • (2002) Anal. Sci. , vol.18 , pp. 1209-1213
    • Diaz-Gonzalez, M.1    Fernandez-Sanchez, C.2    Costa-Garcia, A.3
  • 6
    • 0030754907 scopus 로고    scopus 로고
    • Adsorption of immunoglobulin G in carbon paste electrodes as a basis for the development of immunoelectrochemical devices
    • Fernandez-Sanchez C., Costa-Garcia A. Adsorption of immunoglobulin G in carbon paste electrodes as a basis for the development of immunoelectrochemical devices. Biosens. Bioelectron. 12:1997;403-413
    • (1997) Biosens. Bioelectron. , vol.12 , pp. 403-413
    • Fernandez-Sanchez, C.1    Costa-Garcia, A.2
  • 8
    • 0006658423 scopus 로고
    • Preparation of naphthyl acid phosphates
    • Friedman O.M., Seligman A.M. Preparation of naphthyl acid phosphates. J. Am. Chem. Soc. 72:1950;624-625
    • (1950) J. Am. Chem. Soc. , vol.72 , pp. 624-625
    • Friedman, O.M.1    Seligman, A.M.2
  • 9
    • 0031474208 scopus 로고    scopus 로고
    • Studies towards a disposable screen-printed amperometric biosensor for progesterone
    • Hart J.P., Pemberton R.M., Luxton R., Wedge R. Studies towards a disposable screen-printed amperometric biosensor for progesterone. Biosens. Bioelectron. 12:1997;1113-1121
    • (1997) Biosens. Bioelectron. , vol.12 , pp. 1113-1121
    • Hart, J.P.1    Pemberton, R.M.2    Luxton, R.3    Wedge, R.4
  • 10
    • 0347444724 scopus 로고
    • Reaction and preparation of chlorides of aromatic esters of phosphoric acid-cationic catalysis
    • Katyshkina V.V., Kraft M.Y. Reaction and preparation of chlorides of aromatic esters of phosphoric acid-cationic catalysis. J. Gen. Chem. 26:1953;3407-3411
    • (1953) J. Gen. Chem. , vol.26 , pp. 3407-3411
    • Katyshkina, V.V.1    Kraft, M.Y.2
  • 11
    • 0029962502 scopus 로고    scopus 로고
    • Ferrocenylethyl phosphate: An improved substrate for the detection of alkaline phosphatase by cathodic stripping ion-exchange voltammetry
    • Limoges B., Degrand C. Ferrocenylethyl phosphate: an improved substrate for the detection of alkaline phosphatase by cathodic stripping ion-exchange voltammetry. Anal. Chem. 68:1996;4141-4148
    • (1996) Anal. Chem. , vol.68 , pp. 4141-4148
    • Limoges, B.1    Degrand, C.2
  • 12
    • 0025856946 scopus 로고
    • Highly-sensitive measurement of hydroquinone with an enzyme electrode
    • Mizutani F., Yabuki S., Asai M. Highly-sensitive measurement of hydroquinone with an enzyme electrode. Biosens. Bioelectron. 6:1991;305-310
    • (1991) Biosens. Bioelectron. , vol.6 , pp. 305-310
    • Mizutani, F.1    Yabuki, S.2    Asai, M.3
  • 13
    • 0027615898 scopus 로고
    • Small-volume voltammetric detection of 4-aminophenol with interdigitated array electrodes and its application to electrochemical enzyme immunoassay
    • Niwi O., Xu Y., Halsall H.B., Heineman W.R. Small-volume voltammetric detection of 4-aminophenol with interdigitated array electrodes and its application to electrochemical enzyme immunoassay. Anal. Chem. 65:1993;1559-1563
    • (1993) Anal. Chem. , vol.65 , pp. 1559-1563
    • Niwi, O.1    Xu, Y.2    Halsall, H.B.3    Heineman, W.R.4
  • 14
    • 0032310879 scopus 로고    scopus 로고
    • Development of a sensitive, selective electrochemical immunoassay for progesterone in cow's milk based on disposable screen-printed amperometric biosensor
    • Pemberton R.M., Hart J.P., Foulkes J.A. Development of a sensitive, selective electrochemical immunoassay for progesterone in cow's milk based on disposable screen-printed amperometric biosensor. Electrochim. Acta. 43:1998;3567-3574
    • (1998) Electrochim. Acta , vol.43 , pp. 3567-3574
    • Pemberton, R.M.1    Hart, J.P.2    Foulkes, J.A.3
  • 15
    • 0032310879 scopus 로고    scopus 로고
    • Development of a sensitive, selective electrochemical immunoassay for progesterone in cow's milk based on disposable screen-printed amperometric biosensor
    • Pemberton R.M., Hart J.P., Foulkes J.A. Development of a sensitive, selective electrochemical immunoassay for progesterone in cow's milk based on disposable screen-printed amperometric biosensor. Electrochim. Acta. 43:1998;3567-3574
    • (1998) Electrochim. Acta , vol.43 , pp. 3567-3574
    • Pemberton, R.M.1    Hart, J.P.2    Foulkes, J.A.3
  • 16
    • 0033620590 scopus 로고    scopus 로고
    • A comparison of 1-naphthyl phosphate and 4-aminophenyl phosphate as enzyme substrates for use with a screen-printed amperometric immunosensor for progesterone in cow's milk
    • Pemberton R.M., Hart J.P., Stoddard P., Foulkes J.A. A comparison of 1-naphthyl phosphate and 4-aminophenyl phosphate as enzyme substrates for use with a screen-printed amperometric immunosensor for progesterone in cow's milk. Biosens. Bioelectron. 14:1999;495-503
    • (1999) Biosens. Bioelectron. , vol.14 , pp. 495-503
    • Pemberton, R.M.1    Hart, J.P.2    Stoddard, P.3    Foulkes, J.A.4
  • 17
    • 0029688141 scopus 로고    scopus 로고
    • Applications of electrochemical immunosensors to environmental monitoring
    • Sadik O.A., Van Emon J.M. Applications of electrochemical immunosensors to environmental monitoring. Biosens. Bioelectron. 11:1996;i-xi
    • (1996) Biosens. Bioelectron. , vol.11
    • Sadik, O.A.1    Van Emon, J.M.2
  • 18
    • 0031150136 scopus 로고    scopus 로고
    • Amperometric immunosensors based on rigid conducting immunocomposites
    • Santandreu M., Cespedes F., Alegret S., Martinez-Fabregas E. Amperometric immunosensors based on rigid conducting immunocomposites. Anal. Chem. 69:1997;2080-2085
    • (1997) Anal. Chem. , vol.69 , pp. 2080-2085
    • Santandreu, M.1    Cespedes, F.2    Alegret, S.3    Martinez-Fabregas, E.4
  • 19
    • 0031445624 scopus 로고    scopus 로고
    • An immunosensor based on disposable electrodes for rapid estimation of fatty acid-binding protein, an early marker of myocardial infection
    • Schreiber A., Feldbrugge R., Key G., Glatz J.F.C., Spencer F. An immunosensor based on disposable electrodes for rapid estimation of fatty acid-binding protein, an early marker of myocardial infection. Biosens. Bioelectron. 12:1997;1131-1137
    • (1997) Biosens. Bioelectron. , vol.12 , pp. 1131-1137
    • Schreiber, A.1    Feldbrugge, R.2    Key, G.3    Glatz, J.F.C.4    Spencer, F.5
  • 20
    • 0346789278 scopus 로고    scopus 로고
    • Advances in electrochemical immunosensors
    • Skladal P. Advances in electrochemical immunosensors. Electroanalysis. 9:1997;737-745
    • (1997) Electroanalysis , vol.9 , pp. 737-745
    • Skladal, P.1
  • 21
    • 0015240396 scopus 로고
    • Fluorescence of studies of the binding of alkyl and aryl phosphates to rat muscle aldolase
    • Suh B., Barker R. Fluorescence of studies of the binding of alkyl and aryl phosphates to rat muscle aldolase. J. Biol. Chem. 246:1971;7041-7046
    • (1971) J. Biol. Chem. , vol.246 , pp. 7041-7046
    • Suh, B.1    Barker, R.2
  • 22
    • 0000127753 scopus 로고
    • P-Aminophenyl phosphate: An improved substrate for electrochemical enzyme immunoassay
    • Tang H.T., Lunte C.E., Halsall H.B., Heineman W.R. p-Aminophenyl phosphate: an improved substrate for electrochemical enzyme immunoassay. Anal. Chim. Acta. 214:1988;187-195
    • (1988) Anal. Chim. Acta , vol.214 , pp. 187-195
    • Tang, H.T.1    Lunte, C.E.2    Halsall, H.B.3    Heineman, W.R.4
  • 23
    • 0026033041 scopus 로고
    • Comparison of methods for following alkaline phosphatase catalysis: Spectrophotometric versus amperometric detection
    • Thompson R.Q., Barone G.C. III, Halsall H.B., Heineman W.R. Comparison of methods for following alkaline phosphatase catalysis: spectrophotometric versus amperometric detection. Anal. Biochem. 192:1991;90-95
    • (1991) Anal. Biochem. , vol.192 , pp. 90-95
    • Thompson, R.Q.1    Barone III, G.C.2    Halsall, H.B.3    Heineman, W.R.4
  • 24
    • 0032520399 scopus 로고    scopus 로고
    • Sol-gel derived thick-film amperometric immunosensors
    • Wang J., Pamidi P.V. Sol-gel derived thick-film amperometric immunosensors. Anal. Chem. 70:1998;1171-1175
    • (1998) Anal. Chem. , vol.70 , pp. 1171-1175
    • Wang, J.1    Pamidi, P.V.2
  • 25
    • 0346725026 scopus 로고    scopus 로고
    • Novel amperometric immunosensors based on iridium oxide matrices
    • Wilson M.S., Rauh R.D. Novel amperometric immunosensors based on iridium oxide matrices. Biosens. Bioelectron. 19:2004;693-699
    • (2004) Biosens. Bioelectron. , vol.19 , pp. 693-699
    • Wilson, M.S.1    Rauh, R.D.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.