메뉴 건너뛰기




Volumn 51, Issue 6, 2002, Pages 1316-1321

A DSP-based FFT-analyzer for the fault diagnosis of rotating machine based on vibration analysis

Author keywords

DSP; Fault diagnosis; Frequency domain analysis; Rotating machines; Vibration analysis

Indexed keywords

DSP; FAULT DIAGNOSIS; VIBRATION ANALYSIS;

EID: 4043048955     PISSN: 00189456     EISSN: None     Source Type: Journal    
DOI: 10.1109/TIM.2002.807987     Document Type: Article
Times cited : (170)

References (29)
  • 2
    • 0028683181 scopus 로고
    • Mechanical vibration of three-phase induction motors fed by nonsinusoidal currents
    • R. A. Munoz and C. G. Nahmias, "Mechanical vibration of three-phase induction motors fed by nonsinusoidal currents," in Proc. Int. Power Electron. Congr., 1994, pp. 166-172.
    • (1994) Proc. Int. Power Electron. Congr. , pp. 166-172
    • Munoz, R.A.1    Nahmias, C.G.2
  • 4
    • 0032202215 scopus 로고    scopus 로고
    • A method for sensorless on-line vibration monitoring of induction machines
    • Dec.
    • C. M. Riley, B. K. Lin, T. G. Habetler, and R. R. Schoen, "A method for sensorless on-line vibration monitoring of induction machines," IEEE Trans. Ind. Applicat., vol. 34, pp. 1240-1245, Dec. 1998.
    • (1998) IEEE Trans. Ind. Applicat. , vol.34 , pp. 1240-1245
    • Riley, C.M.1    Lin, B.K.2    Habetler, T.G.3    Schoen, R.R.4
  • 6
    • 0033318113 scopus 로고    scopus 로고
    • Robust machine fault detection with independent component analysis and support vector data description
    • A. Ypma, D. M. J. Tax, and R. P. W. Duin, "Robust machine fault detection with independent component analysis and support vector data description," Proc. IEEE Int. Workshop Neural Network Signal Processing, pp. 67-76, 1999.
    • (1999) Proc. IEEE Int. Workshop Neural Network Signal Processing , pp. 67-76
    • Ypma, A.1    Tax, D.M.J.2    Duin, R.P.W.3
  • 9
    • 0034270929 scopus 로고    scopus 로고
    • An analytical approach to solving motor vibration problems
    • Oct.
    • W. R. Finley, M. M. Hodowanec, and W. G. Holler, "An analytical approach to solving motor vibration problems," IEEE Trans. Ind. Applicat., vol. 36, pp. 1467-1480, Oct. 2000.
    • (2000) IEEE Trans. Ind. Applicat. , vol.36 , pp. 1467-1480
    • Finley, W.R.1    Hodowanec, M.M.2    Holler, W.G.3
  • 11
    • 0019636227 scopus 로고
    • Spectrum analysis - A modern prospective
    • M. Kay and S. L. Marple, "Spectrum analysis - A modern prospective," Proc. Inst. Elect. Eng., vol. 69, 1981.
    • (1981) Proc. Inst. Elect. Eng. , vol.69
    • Kay, M.1    Marple, S.L.2
  • 13
    • 0026105251 scopus 로고
    • Embedding spectral analysis in equipment
    • S. Jangi and Y. Jain, "Embedding spectral analysis in equipment," IEEE Spectrum, pp. 40-43, 1991.
    • (1991) IEEE Spectrum , pp. 40-43
    • Jangi, S.1    Jain, Y.2
  • 15
    • 0034297837 scopus 로고    scopus 로고
    • Neural-network-based motor rolling bearing fault diagnosis
    • Oct.
    • B. Li, M. Y. Chow, Y. Tipsuwan, and J. C. Hung, "Neural-network- based motor rolling bearing fault diagnosis," IEEE Trans. Ind. Electron., vol. 47, pp. 1060-1069, Oct. 2000.
    • (2000) IEEE Trans. Ind. Electron. , vol.47 , pp. 1060-1069
    • Li, B.1    Chow, M.Y.2    Tipsuwan, Y.3    Hung, J.C.4
  • 16
    • 27744504226 scopus 로고
    • Effective machinery measurement using dynamic signal analyzers
    • "Effective Machinery Measurement Using Dynamic Signal Analyzers," Hewlett Packard, Applicat. Note 243-1, 1990.
    • (1990) Hewlett Packard, Applicat. Note , vol.243 , Issue.1
  • 17
    • 0026850997 scopus 로고
    • The influence of windowing on the accuracy of multifrequency signal parameter estimation
    • Apr.
    • C. Offelli and D. Petri, "The influence of windowing on the accuracy of multifrequency signal parameter estimation," IEEE Trans. Instrum. Meas., vol. 41, pp. 256-264, Apr. 1992.
    • (1992) IEEE Trans. Instrum. Meas. , vol.41 , pp. 256-264
    • Offelli, C.1    Petri, D.2
  • 20
    • 0035363028 scopus 로고    scopus 로고
    • A multi-application FFT-analyzer based on a DSP architecture
    • to be published
    • G. Betta, C. Liguori, and A. Pietrosanto, A multi-application FFT-analyzer based on a DSP architecture, in IEEE Trans. Instrum. Meas., pp. 825-832, 2001, to be published.
    • (2001) IEEE Trans. Instrum. Meas. , pp. 825-832
    • Betta, G.1    Liguori, C.2    Pietrosanto, A.3
  • 21
    • 33747904545 scopus 로고    scopus 로고
    • Setting up and characterization of multiple-DSP measurement stations
    • Budapest, Hungary
    • A. Bernieri, G. Betta, and C. Liguori, "Setting up and characterization of multiple-DSP measurement stations," in Proc. IMEKO TC-4 Int. Symp., Budapest, Hungary, 1996, pp. 282-285.
    • (1996) Proc. IMEKO TC-4 Int. Symp. , pp. 282-285
    • Bernieri, A.1    Betta, G.2    Liguori, C.3
  • 22
    • 0003662622 scopus 로고    scopus 로고
    • Real-time re-configuration of multi-DSP measurement stations
    • Glasgow, U.K.
    • _, "Real-time re-configuration of multi-DSP measurement stations," in Proc. IMEKO TC-4 Inte. Symp., Glasgow, U.K., 1997, pp. 253-256.
    • (1997) Proc. IMEKO TC-4 Inte. Symp. , pp. 253-256
  • 23
    • 0029535910 scopus 로고
    • Model-based methods for fault diagnosis: Some guidelines
    • R. J. Patton, J. Chen, and S. B. Nielsen, "Model-based methods for fault diagnosis: Some guidelines," Trans. Meas. Control, vol. 17, pp. 73-83, 1995.
    • (1995) Trans. Meas. Control , vol.17 , pp. 73-83
    • Patton, R.J.1    Chen, J.2    Nielsen, S.B.3
  • 24
    • 0030271146 scopus 로고    scopus 로고
    • On-line fault detection and diagnosis obtained by implementing neural algorithms on a digital signal processor
    • Oct.
    • A. Bernieri, G. Betta, and C. Liguori, "On-line fault detection and diagnosis obtained by implementing neural algorithms on a digital signal processor," IEEE Trans. Instrum. Meas., vol. 45, pp. 894-899, Oct. 1996.
    • (1996) IEEE Trans. Instrum. Meas. , vol.45 , pp. 894-899
    • Bernieri, A.1    Betta, G.2    Liguori, C.3
  • 25
    • 0031165173 scopus 로고    scopus 로고
    • A digital-signal-processor-based measurement system for on-line fault detection
    • June
    • A. Baccigalupi, A. Bernieri, and A. Pietrosanto, "A digital-signal-processor-based measurement system for on-line fault detection," IEEE Trans. Instrum. Meas., vol. 46, pp. 731-736, June 1997.
    • (1997) IEEE Trans. Instrum. Meas. , vol.46 , pp. 731-736
    • Baccigalupi, A.1    Bernieri, A.2    Pietrosanto, A.3
  • 26
    • 0024717012 scopus 로고
    • Windows and interpolation algorithms to improve electrical measurement accuracy
    • Aug.
    • G. Andria, M. Savino, and A. Trotta, "Windows and interpolation algorithms to improve electrical measurement accuracy," IEEE Trans. Instrum. Meas., vol. 88, pp. 856-863, Aug. 1989.
    • (1989) IEEE Trans. Instrum. Meas. , vol.88 , pp. 856-863
    • Andria, G.1    Savino, M.2    Trotta, A.3
  • 27
    • 0025385198 scopus 로고
    • Interpolation techniques for real-time multifrequency waveform analysis
    • Feb.
    • C. Offelli and D. Petri, "Interpolation techniques for real-time multifrequency waveform analysis," IEEE Trans. Instrum. Meas., vol. 39, pp. 106-111, Feb. 1990.
    • (1990) IEEE Trans. Instrum. Meas. , vol.39 , pp. 106-111
    • Offelli, C.1    Petri, D.2
  • 28
    • 0029516027 scopus 로고
    • A knowledge-based approach to instrument fault detection and isolation
    • Dec.
    • G. Betta, M. D'Apuzzo, and A. Pietrosanto, "A knowledge-based approach to instrument fault detection and isolation," IEEE Trans. Instrum. Meas., vol. 44, pp. 1009-1016, Dec., 1995.
    • (1995) IEEE Trans. Instrum. Meas. , vol.44 , pp. 1009-1016
    • Betta, G.1    D'Apuzzo, M.2    Pietrosanto, A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.