메뉴 건너뛰기




Volumn , Issue , 2007, Pages 2734-2736

Commissioning of the linac for the Heidelberg heavy ion cancer therapy centre (HIT)

Author keywords

[No Author keywords available]

Indexed keywords

ELECTRIC IMPEDANCE; ELECTRON CYCLOTRON RESONANCE; HELIUM; INDUCTION HEATING; ION BOMBARDMENT; ION SOURCES; PARTICLE ACCELERATORS; VIBRATION ANALYSIS;

EID: 40349107110     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/PAC.2007.4440558     Document Type: Conference Paper
Times cited : (6)

References (8)
  • 1
    • 51349083635 scopus 로고    scopus 로고
    • H. Eickhoff et al., HICAT - The German Hospital-Based Light Ion Cancer Therapy Project, Proc. EPAC 2004, p. 290.
    • H. Eickhoff et al., HICAT - The German Hospital-Based Light Ion Cancer Therapy Project, Proc. EPAC 2004, p. 290.
  • 2
    • 51349153806 scopus 로고    scopus 로고
    • Status of the 7 MeV/u, 217 MHz Injector Linac for the Heidelberg Cancer Therapy Facility
    • B. Schlitt et al., Status of the 7 MeV/u, 217 MHz Injector Linac for the Heidelberg Cancer Therapy Facility, Proc. LINAC 2004, p. 51.
    • (2004) Proc. LINAC , pp. 51
    • Schlitt, B.1
  • 3
    • 4143146484 scopus 로고    scopus 로고
    • A. Bechtold et al., Status of the Integrated RFQ-Drifttube-Combination for the Medicine-Synchrotron in Heidelberg, Proc. PAC 2003, p. 1062.
    • A. Bechtold et al., Status of the Integrated RFQ-Drifttube-Combination for the Medicine-Synchrotron in Heidelberg, Proc. PAC 2003, p. 1062.
  • 4
    • 51349123485 scopus 로고    scopus 로고
    • Y. Lu et al., The Compact 20 MV IH-DTL for the Heidelberg Therapy Facility, LINAC 2004, p. 57.
    • Y. Lu et al., The Compact 20 MV IH-DTL for the Heidelberg Therapy Facility, LINAC 2004, p. 57.
  • 5
    • 84888347526 scopus 로고    scopus 로고
    • Commissioning of the 7 MeV/u, 217 MHz Injector Linac for the Heavy Ion Cancer Therapy Facility at the University Clinics in Heidelberg
    • B. Schlitt et al, Commissioning of the 7 MeV/u, 217 MHz Injector Linac for the Heavy Ion Cancer Therapy Facility at the University Clinics in Heidelberg, Proc. LINAC 2006, p. 148.
    • (2006) Proc. LINAC , pp. 148
    • Schlitt, B.1
  • 6
    • 51349161032 scopus 로고    scopus 로고
    • Testbench of the HIT RFQ at GSI
    • C. Kleffner et al., Testbench of the HIT RFQ at GSI, Proc. LINAC 2006, p. 791.
    • (2006) Proc. LINAC , pp. 791
    • Kleffner, C.1
  • 8
    • 51349105319 scopus 로고    scopus 로고
    • Assembly and RF Tuning of the IH-DTL for the HIT Linac
    • G. Clemente, H. Vormann et al., Assembly and RF Tuning of the IH-DTL for the HIT Linac, GSI Scientific Report 2006, p. 376.
    • GSI Scientific Report 2006 , pp. 376
    • Clemente, G.1    Vormann, H.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.