1
-
-
0027575844
-
Macroscopic and microscopic wear mechanisms in ultra-high molecular weight polyethylene
-
Cooper J.R., Dowson D., and Fisher J. Macroscopic and microscopic wear mechanisms in ultra-high molecular weight polyethylene. Wear 162-164 (1993) 378-384
-
(1993)
Wear
, vol.162-164
, pp. 378-384
-
-
Cooper, J.R.1
Dowson, D.2
Fisher, J.3
-
2
-
-
0002651567
-
Prognosis of total hip replacement
-
Dallas, USA, February 13-17 http://www.jru.orthop.gu.se
-
Malchau H., Herberts P., Garellick G., Söderman P., and Eisler T. Prognosis of total hip replacement. Scientific Exhibition Presented at the 69th Annual Meeting of the American Academy of Orthopaedic Surgeons. Dallas, USA, February 13-17 (2002). http://www.jru.orthop.gu.se/ http://www.jru.orthop.gu.se
-
(2002)
Scientific Exhibition Presented at the 69th Annual Meeting of the American Academy of Orthopaedic Surgeons
-
-
Malchau, H.1
Herberts, P.2
Garellick, G.3
Söderman, P.4
Eisler, T.5
-
3
-
-
0032170254
-
Titanium alloys in total joint replacement-a materials science perspective
-
Long M., and Rack H.J. Titanium alloys in total joint replacement-a materials science perspective. Biomaterials 19 (1998) 1621-1639
-
(1998)
Biomaterials
, vol.19
, pp. 1621-1639
-
-
Long, M.1
Rack, H.J.2
-
4
-
-
0343384352
-
The in vivo wear performance of prosthetic femoral heads with titanium nitride coating
-
Raimondi M.T., and Pietrabissa R. The in vivo wear performance of prosthetic femoral heads with titanium nitride coating. Biomaterials 21 (2000) 907-913
-
(2000)
Biomaterials
, vol.21
, pp. 907-913
-
-
Raimondi, M.T.1
Pietrabissa, R.2
-
5
-
-
0037472816
-
Tribological and electrochemical performance of PVD TiN coatings on the femoral head of Ti-6Al-4V artificial hip joints
-
Liu C., Bi Q., and Matthew A. Tribological and electrochemical performance of PVD TiN coatings on the femoral head of Ti-6Al-4V artificial hip joints. Surf. Coat. Technol. 163-164 (2003) 597-604
-
(2003)
Surf. Coat. Technol.
, vol.163-164
, pp. 597-604
-
-
Liu, C.1
Bi, Q.2
Matthew, A.3
-
6
-
-
40049096852
-
-
D. Braun, M. Braun, Micronite. A New Generation of Surface Treatment, Micromy, Täby, Sweden, 2001.
-
D. Braun, M. Braun, Micronite. A New Generation of Surface Treatment, Micromy, Täby, Sweden, 2001.
-
-
-
-
7
-
-
0037165927
-
Diamond-like amorphous carbon
-
Robertson J. Diamond-like amorphous carbon. Mater. Sci. Eng. 3724 (2002) 129-281
-
(2002)
Mater. Sci. Eng.
, vol.3724
, pp. 129-281
-
-
Robertson, J.1
-
8
-
-
0037852937
-
A review of modified DLC coatings for biological applications
-
Hauert R. A review of modified DLC coatings for biological applications. Diam. Relat. Mater. 12 (2003) 583-589
-
(2003)
Diam. Relat. Mater.
, vol.12
, pp. 583-589
-
-
Hauert, R.1
-
9
-
-
0034043773
-
An in vitro investigation of diamond-like carbon as a femoral head coating
-
Affatato S., Frigo M., and Toni A. An in vitro investigation of diamond-like carbon as a femoral head coating. J. Biomed. Mater. (Appl. Biomater.) 53 (2000) 221-226
-
(2000)
J. Biomed. Mater. (Appl. Biomater.)
, vol.53
, pp. 221-226
-
-
Affatato, S.1
Frigo, M.2
Toni, A.3
-
10
-
-
0033980019
-
Quantitative analysis of ultrahigh molecular weight polyethylene (UHMWPE) wear debris associated with total knee replacements
-
Shanbhag A.S., Bailey H.O., Hwang D.-S., Cha C.W., Erer N.G., and Rubash H.E. Quantitative analysis of ultrahigh molecular weight polyethylene (UHMWPE) wear debris associated with total knee replacements. J. Biomed. Mater. (Appl. Biomater.) 53 (2000) 100-110
-
(2000)
J. Biomed. Mater. (Appl. Biomater.)
, vol.53
, pp. 100-110
-
-
Shanbhag, A.S.1
Bailey, H.O.2
Hwang, D.-S.3
Cha, C.W.4
Erer, N.G.5
Rubash, H.E.6
-
11
-
-
0035482516
-
Characterisation of wear debris from UHMWPE on zirconia ceramic, metal-on-metal and aluminia ceramic-on-ceramic hip prosteses generated in a physiological anatomical hip joint simulator
-
Tipper J.L., Firkins P.J., Besong A.A., Barbour P.S.M., Nevelos J., Stone M.H., Ingham E., and Fisher J. Characterisation of wear debris from UHMWPE on zirconia ceramic, metal-on-metal and aluminia ceramic-on-ceramic hip prosteses generated in a physiological anatomical hip joint simulator. Wear 250 (2001) 120-128
-
(2001)
Wear
, vol.250
, pp. 120-128
-
-
Tipper, J.L.1
Firkins, P.J.2
Besong, A.A.3
Barbour, P.S.M.4
Nevelos, J.5
Stone, M.H.6
Ingham, E.7
Fisher, J.8
-
12
-
-
0028929254
-
Isolation of predominantly submicron-sized UHMWPE wear particles from periprosthetic tissues
-
Campbell P., Ma S., Yeom B., McKellop H., Schmalzried T.P., and Amstutz H.C. Isolation of predominantly submicron-sized UHMWPE wear particles from periprosthetic tissues. J. Biomed. Mater. Res. 29 (1995) 127-131
-
(1995)
J. Biomed. Mater. Res.
, vol.29
, pp. 127-131
-
-
Campbell, P.1
Ma, S.2
Yeom, B.3
McKellop, H.4
Schmalzried, T.P.5
Amstutz, H.C.6
-
13
-
-
0036381564
-
Standardized analysis of UHMWPE wear particles from failed total joint arthroplasties
-
Mabrey J.D., Afsar-Keshmiri A., Engh G.A., Sychterz C.J., Wirth M.A., Rockwood C.A., and Agrawal C.M. Standardized analysis of UHMWPE wear particles from failed total joint arthroplasties. J. Biomed. Mater. Res. (Appl. Biomater.) 63 (2002) 475-483
-
(2002)
J. Biomed. Mater. Res. (Appl. Biomater.)
, vol.63
, pp. 475-483
-
-
Mabrey, J.D.1
Afsar-Keshmiri, A.2
Engh, G.A.3
Sychterz, C.J.4
Wirth, M.A.5
Rockwood, C.A.6
Agrawal, C.M.7
-
14
-
-
0034923905
-
Isolation and morphological characterisation of UHMWPE wear debris generated in vitro
-
Affatato S., Fernandes B., Tucci A., Esposito L., and Toni A. Isolation and morphological characterisation of UHMWPE wear debris generated in vitro. Biomaterials 22 (2001) 2324-2331
-
(2001)
Biomaterials
, vol.22
, pp. 2324-2331
-
-
Affatato, S.1
Fernandes, B.2
Tucci, A.3
Esposito, L.4
Toni, A.5
-
15
-
-
40049083764
-
A review on ultrahigh molecular weight polyethylene
-
Lund University Hospital
-
Bengtsson P. A review on ultrahigh molecular weight polyethylene. Department of Orthopedics (1997), Lund University Hospital
-
(1997)
Department of Orthopedics
-
-
Bengtsson, P.1
-
16
-
-
0033980019
-
Quantitative analysis of ultrahigh molecular weight polyethylene (UHMWPE) wear debris associated with total knee replacements
-
Shanbhag A.S., Bailey H.O., Hwang D.-S., Cha C.W., Erer N.G., and Rubash H.E. Quantitative analysis of ultrahigh molecular weight polyethylene (UHMWPE) wear debris associated with total knee replacements. J. Biomed. Mater. Res. (Appl. Biomater.) 53 (2000) 100-110
-
(2000)
J. Biomed. Mater. Res. (Appl. Biomater.)
, vol.53
, pp. 100-110
-
-
Shanbhag, A.S.1
Bailey, H.O.2
Hwang, D.-S.3
Cha, C.W.4
Erer, N.G.5
Rubash, H.E.6
-
17
-
-
0035222710
-
A novel method for the prediction of functional biological activity of polyethylene wear debris
-
Fisher J., Bell J., Barbour R.S.M., Tipper J.L., Matthews J.B., Besong A.A., Stone M.H., and Ingham E. A novel method for the prediction of functional biological activity of polyethylene wear debris. Proceedings of the Institution of Mechanical Engineers, vol. 215, part H (2000)
-
(2000)
Proceedings of the Institution of Mechanical Engineers, vol. 215, part H
-
-
Fisher, J.1
Bell, J.2
Barbour, R.S.M.3
Tipper, J.L.4
Matthews, J.B.5
Besong, A.A.6
Stone, M.H.7
Ingham, E.8
-
18
-
-
29144497492
-
-
Department of Engineering Metals, Chalmers University of Technology, Gothenburg, Sweden ISSN 1402-7399 2000
-
Hoseini M. Tribology of Artificial Joints (2001), Department of Engineering Metals, Chalmers University of Technology, Gothenburg, Sweden ISSN 1402-7399 2000
-
(2001)
Tribology of Artificial Joints
-
-
Hoseini, M.1
-
21
-
-
0028446277
-
The effect of sliding velocity on the friction and wear of UHMWPE for use in artificial joints
-
Fisher J., Dowson D., Hamdzah H., and Lee H.L. The effect of sliding velocity on the friction and wear of UHMWPE for use in artificial joints. Wear 175 (1994) 219-225
-
(1994)
Wear
, vol.175
, pp. 219-225
-
-
Fisher, J.1
Dowson, D.2
Hamdzah, H.3
Lee, H.L.4
|