메뉴 건너뛰기




Volumn 74, Issue 3, 2008, Pages 235-236

A knot in the heart

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; ANAMNESIS; ARTICLE; CASE REPORT; CLINICAL FEATURE; FEMALE; HUMAN; LAPAROTOMY; OUTCOME ASSESSMENT; PULMONARY ARTERY CATHETER; SMALL INTESTINE OBSTRUCTION; SWAN GANZ CATHETER; THORAX RADIOGRAPHY;

EID: 40049100019     PISSN: 00031348     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (10)

References (9)
  • 1
    • 0014964972 scopus 로고
    • Catheterization of the heart in man with use of a flow-directed balloon-tipped catheter
    • Swan HJC, Ganz W, Forrester J, et al. Catheterization of the heart in man with use of a flow-directed balloon-tipped catheter. N Engl J Med 1970;283:447-51.
    • (1970) N Engl J Med , vol.283 , pp. 447-451
    • Swan, H.J.C.1    Ganz, W.2    Forrester, J.3
  • 2
    • 0023493373 scopus 로고
    • A community-wide assessment of the use of pulmonary artery catheters in patients with acute myocardial infarction
    • Gore JM, Goldberg RJ, Podik DH, et al. A community-wide assessment of the use of pulmonary artery catheters in patients with acute myocardial infarction. Chest 1987;92:727-31.
    • (1987) Chest , vol.92 , pp. 727-731
    • Gore, J.M.1    Goldberg, R.J.2    Podik, D.H.3
  • 3
    • 9544228424 scopus 로고    scopus 로고
    • The effectiveness of right heart catheterization in the initial care of critically ill patients. SUPPORT Investigators
    • Connors A, Speroff T, Dawson N, et al. The effectiveness of right heart catheterization in the initial care of critically ill patients. SUPPORT Investigators. JAMA 1996;276:889-97.
    • (1996) JAMA , vol.276 , pp. 889-897
    • Connors, A.1    Speroff, T.2    Dawson, N.3
  • 4
    • 0037413466 scopus 로고    scopus 로고
    • A randomized, controlled trial of the use of pulmonary-artery catheters in high-risk surgical patients
    • Sandham JD, Hull RD, Brant L, et al. A randomized, controlled trial of the use of pulmonary-artery catheters in high-risk surgical patients. N Engl J Med 2003;348:5-14.
    • (2003) N Engl J Med , vol.348 , pp. 5-14
    • Sandham, J.D.1    Hull, R.D.2    Brant, L.3
  • 5
    • 0033065479 scopus 로고    scopus 로고
    • The pulmonary artery catheter: Nonexistential entity or occasionally useful tool?
    • Layon AJ. The pulmonary artery catheter: Nonexistential entity or occasionally useful tool? Chest 1999;115:859-62.
    • (1999) Chest , vol.115 , pp. 859-862
    • Layon, A.J.1
  • 6
    • 18144362852 scopus 로고    scopus 로고
    • Knot in the cava - An unusual complication of Swan-Ganz catheters
    • Bagul NB, Menon NJ, Pathak R, et al. Knot in the cava - An unusual complication of Swan-Ganz catheters. Eur J Vasc Endovasc Surg 2005;29:651-3.
    • (2005) Eur J Vasc Endovasc Surg , vol.29 , pp. 651-653
    • Bagul, N.B.1    Menon, N.J.2    Pathak, R.3
  • 7
    • 0036511882 scopus 로고    scopus 로고
    • Removal of knotted intravascular devices. Case report and review of the literature
    • Karanikas ID, Polychronidis A, Vrachatis A, et al. Removal of knotted intravascular devices. Case report and review of the literature. Eur J Vasc Endovasc Surg 2002;23:189-94.
    • (2002) Eur J Vasc Endovasc Surg , vol.23 , pp. 189-194
    • Karanikas, I.D.1    Polychronidis, A.2    Vrachatis, A.3
  • 8
    • 0027676454 scopus 로고
    • The technique of inserting the Swan-Ganz catheter
    • Amin DK, Shah PK, Swan HJC. The technique of inserting the Swan-Ganz catheter. J Crit Illn 1993;8:1147-56.
    • (1993) J Crit Illn , vol.8 , pp. 1147-1156
    • Amin, D.K.1    Shah, P.K.2    Swan, H.J.C.3
  • 9
    • 0020348725 scopus 로고
    • A maneuver for bedside pulmonary artery catheterization in patients with right heart failure
    • Venus B, Mathru M. A maneuver for bedside pulmonary artery catheterization in patients with right heart failure. Chest 1982;82:803-4.
    • (1982) Chest , vol.82 , pp. 803-804
    • Venus, B.1    Mathru, M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.