메뉴 건너뛰기




Volumn 38, Issue 1, 2008, Pages 37-40

Evaluation of the Roche CoaguChek XS handheld coagulation analyzer in a cardiac outpatient clinic

Author keywords

Coagulation analyzer; INR; Point of care testing; Prothrombin time

Indexed keywords

ANTICOAGULANT AGENT; WARFARIN;

EID: 40049099253     PISSN: 00917370     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (27)

References (10)
  • 1
    • 0028791287 scopus 로고
    • Comparing methods of measurement: Why plotting difference against standard method is misleading
    • Bland JM, Altman DG. Comparing methods of measurement: why plotting difference against standard method is misleading. Lancet 1995;346:1085-1087.
    • (1995) Lancet , vol.346 , pp. 1085-1087
    • Bland, J.M.1    Altman, D.G.2
  • 2
    • 33947398004 scopus 로고    scopus 로고
    • Accuracy and clinical utility of the CoaguChek XS portable international normalised ratio monitor in a pilot study of warfarin home-monitoring
    • Bereznicki L, Jackson S, Peterson G, Jeffrey E, Marsden K, Jupe D. Accuracy and clinical utility of the CoaguChek XS portable international normalised ratio monitor in a pilot study of warfarin home-monitoring. J Clin Pathol 2007;60:311-314.
    • (2007) J Clin Pathol , vol.60 , pp. 311-314
    • Bereznicki, L.1    Jackson, S.2    Peterson, G.3    Jeffrey, E.4    Marsden, K.5    Jupe, D.6
  • 3
    • 33947509324 scopus 로고    scopus 로고
    • Performance evaluation of the new CoaguChek XS system compared with the established CoaguChek system by patients experienced in INR-self management
    • Braun S, Watzke H, Hasenkam JM, Schwab M, Wolf T, Dovifat C, Voller H. Performance evaluation of the new CoaguChek XS system compared with the established CoaguChek system by patients experienced in INR-self management. Thromb Haemost 2007;97:310-314.
    • (2007) Thromb Haemost , vol.97 , pp. 310-314
    • Braun, S.1    Watzke, H.2    Hasenkam, J.M.3    Schwab, M.4    Wolf, T.5    Dovifat, C.6    Voller, H.7
  • 4
    • 33646539472 scopus 로고    scopus 로고
    • Validity of criteria used to evaluate fingerstick devices that assess international normalized ratio
    • Shermock KM, Connor JT, Smith NT, Fink JM, Bragg L. Validity of criteria used to evaluate fingerstick devices that assess international normalized ratio. Med Decis Making 2006;26:239-246.
    • (2006) Med Decis Making , vol.26 , pp. 239-246
    • Shermock, K.M.1    Connor, J.T.2    Smith, N.T.3    Fink, J.M.4    Bragg, L.5
  • 5
    • 20444442765 scopus 로고    scopus 로고
    • Long-term stability and reproducibility of CoaguChek test strips
    • van den Besselaar AM, Hoekstra MM. Long-term stability and reproducibility of CoaguChek test strips. Thromb Haemost 2005;93:1189-1192.
    • (2005) Thromb Haemost , vol.93 , pp. 1189-1192
    • van den Besselaar, A.M.1    Hoekstra, M.M.2
  • 7
    • 0036093794 scopus 로고    scopus 로고
    • Accuracy and precision of the CoaguChek S versus laboratory INRs in a clinic
    • Havrda DE, Hawk TL, Marvin CM. Accuracy and precision of the CoaguChek S versus laboratory INRs in a clinic. Ann Pharmacother 2002;36:769-775.
    • (2002) Ann Pharmacother , vol.36 , pp. 769-775
    • Havrda, D.E.1    Hawk, T.L.2    Marvin, C.M.3
  • 8
    • 1242272206 scopus 로고    scopus 로고
    • Accuracy, reproducibility and clinical utility of the CoaguChek S portable international normalized ratio monitor in an outpatient anticoagulation clinic
    • Jackson SL, Bereznicki LR, Peterson GM, Marsden KA, Jupe DM, Tegg E, Vial JH, Kimber RI. Accuracy, reproducibility and clinical utility of the CoaguChek S portable international normalized ratio monitor in an outpatient anticoagulation clinic. Clin Lab Haematol 2004;26:49-55.
    • (2004) Clin Lab Haematol , vol.26 , pp. 49-55
    • Jackson, S.L.1    Bereznicki, L.R.2    Peterson, G.M.3    Marsden, K.A.4    Jupe, D.M.5    Tegg, E.6    Vial, J.H.7    Kimber, R.I.8
  • 9
    • 16844369857 scopus 로고    scopus 로고
    • Analytical performance of the new coagulation monitoring system INRatio for the determination of INR compared with the coagulation monitor CoaguChek S and an established laboratory method
    • Taborski U, Braun SL, Voller H. Analytical performance of the new coagulation monitoring system INRatio for the determination of INR compared with the coagulation monitor CoaguChek S and an established laboratory method. J Thromb Thrombolysis 2004;18:103-107.
    • (2004) J Thromb Thrombolysis , vol.18 , pp. 103-107
    • Taborski, U.1    Braun, S.L.2    Voller, H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.