메뉴 건너뛰기




Volumn 19, Issue 3, 2008, Pages 282-284

The diagnostic evolution of the cardiac implantable electronic device: The implantable monitor of ischemia

Author keywords

[No Author keywords available]

Indexed keywords

ANGIOPLASTY; ARTIFICIAL HEART PACEMAKER; CARDIAC RESYNCHRONIZATION THERAPY; CARDIOMYOPATHY; DEFIBRILLATOR; DEVICE; HEART ATRIUM FIBRILLATION; HEART FAILURE; HEART MUSCLE ISCHEMIA; NOTE; PRIORITY JOURNAL; RADIOFREQUENCY ABLATION; TACHYCARDIA;

EID: 39749188223     PISSN: 10453873     EISSN: 15408167     Source Type: Journal    
DOI: 10.1111/j.1540-8167.2007.01061.x     Document Type: Note
Times cited : (3)

References (13)
  • 2
    • 17044441469 scopus 로고    scopus 로고
    • Historical perspectives on interventional electrophysiology
    • Luderitz B : Historical perspectives on interventional electrophysiology. J Interv Card Electrophysiol 2003 9 : 75 83.
    • (2003) J Interv Card Electrophysiol , vol.9 , pp. 75-83
    • Luderitz, B.1
  • 6
    • 0018257408 scopus 로고
    • Unipolar ventricular electrogram in the diagnosis of right ventricular ischemic injury
    • Varriale P, Niznik J : Unipolar ventricular electrogram in the diagnosis of right ventricular ischemic injury. Pacing Clin Electrophysiol 1978 1 : 335 341.
    • (1978) Pacing Clin Electrophysiol , vol.1 , pp. 335-341
    • Varriale, P.1    Niznik, J.2
  • 8
    • 33845224834 scopus 로고    scopus 로고
    • Real-time detection and alerting for acute ST-segment elevation myocardial ischemia using an implantable, high-fidelity, intracardiac electrogram monitoring system with long-range telemetry in an ambulatory porcine model
    • Fischell TA, Fischell DR, Fischell RE, Virmani R, DeVries JJ, Krucoff MW : Real-time detection and alerting for acute ST-segment elevation myocardial ischemia using an implantable, high-fidelity, intracardiac electrogram monitoring system with long-range telemetry in an ambulatory porcine model. J Am Coll Cardiol 2006 48 : 2306 2314.
    • (2006) J Am Coll Cardiol , vol.48 , pp. 2306-2314
    • Fischell, T.A.1    Fischell, D.R.2    Fischell, R.E.3    Virmani, R.4    Devries, J.J.5    Krucoff, M.W.6
  • 10
    • 0036776110 scopus 로고    scopus 로고
    • Comparison of electrocardiogram and intrathoracic electrogram signals for detection of ischemic ST segment changes during normal sinus and ventricular paced rhythms
    • Theres H, Stadler RW, Stylos L, Glos M, Leuthold T, Baumann G, Nelson SD, Krucoff MW : Comparison of electrocardiogram and intrathoracic electrogram signals for detection of ischemic ST segment changes during normal sinus and ventricular paced rhythms. J Cardiovasc Electrophysiol 2002 13 : 990 995.
    • (2002) J Cardiovasc Electrophysiol , vol.13 , pp. 990-995
    • Theres, H.1    Stadler, R.W.2    Stylos, L.3    Glos, M.4    Leuthold, T.5    Baumann, G.6    Nelson, S.D.7    Krucoff, M.W.8
  • 11
    • 21244478487 scopus 로고    scopus 로고
    • Recurrent infarction causes the most deaths following myocardial infarction with left ventricular dysfunction
    • Orn S, Cleland JG, Romo M, Kjekshus J, Dickstein K : Recurrent infarction causes the most deaths following myocardial infarction with left ventricular dysfunction. Am J Med 2005 118 : 752 758.
    • (2005) Am J Med , vol.118 , pp. 752-758
    • Orn, S.1    Cleland, J.G.2    Romo, M.3    Kjekshus, J.4    Dickstein, K.5
  • 12
    • 39749146495 scopus 로고    scopus 로고
    • Effect of ischemia on implantable defibrillator intracardiac shock electrograms
    • Williams JL, Mendenhall S, Saba S : Effect of ischemia on implantable defibrillator intracardiac shock electrograms. J Cardiovasc Electrophysiol 2008 19 : 275 281.
    • (2008) J Cardiovasc Electrophysiol , vol.19 , pp. 275-281
    • Williams, J.L.1    Mendenhall, S.2    Saba, S.3
  • 13
    • 0025772336 scopus 로고
    • Unipolar versus bipolar pacing-poles apart
    • Mond HG : Unipolar versus bipolar pacing-poles apart. Pacing Clin Electrophysiol 1991 14 : 1411 1424.
    • (1991) Pacing Clin Electrophysiol , vol.14 , pp. 1411-1424
    • Mond, H.G.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.