2
-
-
0025976934
-
Coralline hydroxyapatite as an ocular implant
-
J.J. Dutton Coralline hydroxyapatite as an ocular implant Ophthalmology 98 1991 370 377
-
(1991)
Ophthalmology
, vol.98
, pp. 370-377
-
-
Dutton, J.J.1
-
4
-
-
0028902313
-
Complications of porous spherical orbital implants
-
H.D. Remulla P.A. Rubin J.W. Shore Complications of porous spherical orbital implants Ophthalmology 102 1995 586 593
-
(1995)
Ophthalmology
, vol.102
, pp. 586-593
-
-
Remulla, H.D.1
Rubin, P.A.2
Shore, J.W.3
-
5
-
-
0026651109
-
Tissue breakdown and exposure associated with orbital hydroxyapatite implants
-
H. Buettner G.B. Bartley Tissue breakdown and exposure associated with orbital hydroxyapatite implants Am J Ophthalmol 113 1992 669 673
-
(1992)
Am J Ophthalmol
, vol.113
, pp. 669-673
-
-
Buettner, H.1
Bartley, G.B.2
-
6
-
-
0027235625
-
Exposure rate of hydroxyapatite spheres in the anophthalmic socket: histopathologic correlation and comparison with silicone sphere implants
-
W.R. Nunery G.W. Heinz J.M. Bonnin Exposure rate of hydroxyapatite spheres in the anophthalmic socket: histopathologic correlation and comparison with silicone sphere implants Ophthal Plast Reconstr Surg 9 1993 96 104
-
(1993)
Ophthal Plast Reconstr Surg
, vol.9
, pp. 96-104
-
-
Nunery, W.R.1
Heinz, G.W.2
Bonnin, J.M.3
-
7
-
-
1642515940
-
Coralline hydroxyapatite orbital implant (Bio-Eye): experience with 158 patients
-
D.R. Jordan S. Gilberg A. Bawazeer Coralline hydroxyapatite orbital implant (Bio-Eye): experience with 158 patients Ophthal Plast Reconstr Surg 20 2004 69 74
-
(2004)
Ophthal Plast Reconstr Surg
, vol.20
, pp. 69-74
-
-
Jordan, D.R.1
Gilberg, S.2
Bawazeer, A.3
-
8
-
-
4644312577
-
Problems after evisceration surgery with porous orbital implants: experience with 86 patients
-
D.R. Jordan Problems after evisceration surgery with porous orbital implants: experience with 86 patients Ophthal Plast Reconstr Surg 20 2004 374 380
-
(2004)
Ophthal Plast Reconstr Surg
, vol.20
, pp. 374-380
-
-
Jordan, D.R.1
-
9
-
-
3242812181
-
Current trends in managing the anophthalmic socket after primary enucleation and evisceration
-
G.W. Su M.T. Yen Current trends in managing the anophthalmic socket after primary enucleation and evisceration Ophthal Plast Reconstr Surg 20 2004 274 280
-
(2004)
Ophthal Plast Reconstr Surg
, vol.20
, pp. 274-280
-
-
Su, G.W.1
Yen, M.T.2
-
10
-
-
0028802537
-
Modification of the scleral openings to reduce tissue breakdown and exposure after hydroxyapatite implantations
-
S.Y. Lee O.W. Kwon Y.J. Hong Modification of the scleral openings to reduce tissue breakdown and exposure after hydroxyapatite implantations Ophthalmologica 209 1995 319 322
-
(1995)
Ophthalmologica
, vol.209
, pp. 319-322
-
-
Lee, S.Y.1
Kwon, O.W.2
Hong, Y.J.3
-
11
-
-
0033497557
-
Comparative motility of hydroxyapatite and alloplastic enucleation implants
-
P.L. Custer K.M. Trinkaus J. Fornoff Comparative motility of hydroxyapatite and alloplastic enucleation implants Ophthalmology 106 1999 513 516
-
(1999)
Ophthalmology
, vol.106
, pp. 513-516
-
-
Custer, P.L.1
Trinkaus, K.M.2
Fornoff, J.3
-
13
-
-
0036190413
-
Complications in motility peg placement for hydroxyapatite orbital implant in anophthalmic socket
-
S.Y. Lee J.W. Jang H. Lew Complications in motility peg placement for hydroxyapatite orbital implant in anophthalmic socket Jpn J Ophthalmol 46 2002 103 107
-
(2002)
Jpn J Ophthalmol
, vol.46
, pp. 103-107
-
-
Lee, S.Y.1
Jang, J.W.2
Lew, H.3
-
14
-
-
0032449464
-
Intraorbital implants after enucleation and their complications: a 10-year review
-
N.J. Christmas C.D. Gordon T.G. Murray Intraorbital implants after enucleation and their complications: a 10-year review Arch Ophthalmol 116 1998 1199 1203
-
(1998)
Arch Ophthalmol
, vol.116
, pp. 1199-1203
-
-
Christmas, N.J.1
Gordon, C.D.2
Murray, T.G.3
-
15
-
-
0038175121
-
Bovine pericardium versus homologous sclera as a wrapping for hydroxyapatite orbital implants
-
Y.O. Arat D.J. Shetlar M. Boniuk Bovine pericardium versus homologous sclera as a wrapping for hydroxyapatite orbital implants Ophthal Plast Reconstr Surg 19 2003 189 193
-
(2003)
Ophthal Plast Reconstr Surg
, vol.19
, pp. 189-193
-
-
Arat, Y.O.1
Shetlar, D.J.2
Boniuk, M.3
-
16
-
-
0030911349
-
Human dura mater as a wrapping material for hydroxyapatite implantation in the anophthalmic socket
-
S.Y. Lee H.Y. Kim S.J. Kim S.J. Kang Human dura mater as a wrapping material for hydroxyapatite implantation in the anophthalmic socket Ophthalmic Surg Lasers 28 1997 428 431
-
(1997)
Ophthalmic Surg Lasers
, vol.28
, pp. 428-431
-
-
Lee, S.Y.1
Kim, H.Y.2
Kim, S.J.3
Kang, S.J.4
-
17
-
-
0033816078
-
Creutzfeldt-Jakob disease associated with cadaveric dura mater grafts in Japan
-
K. Hoshi H. Yoshino J. Urata Creutzfeldt-Jakob disease associated with cadaveric dura mater grafts in Japan Neurology 55 2000 718 721
-
(2000)
Neurology
, vol.55
, pp. 718-721
-
-
Hoshi, K.1
Yoshino, H.2
Urata, J.3
-
18
-
-
0031018705
-
Complications of hydroxyapatite orbital implants: a review of 100 consecutive cases and a comparison of Dexon mesh (polyglycolic acid) with scleral wrapping
-
J.H. Oestreicher E. Liu M. Berkowitz Complications of hydroxyapatite orbital implants: a review of 100 consecutive cases and a comparison of Dexon mesh (polyglycolic acid) with scleral wrapping Ophthalmology 104 1997 324 329
-
(1997)
Ophthalmology
, vol.104
, pp. 324-329
-
-
Oestreicher, J.H.1
Liu, E.2
Berkowitz, M.3
-
19
-
-
0029016072
-
The use of Vicryl mesh (polyglactin 910) for implantation of hydroxyapatite orbital implants
-
D.R. Jordan L.H. Allen A. Ells The use of Vicryl mesh (polyglactin 910) for implantation of hydroxyapatite orbital implants Ophthal Plast Reconstr Surg 11 1995 95 99
-
(1995)
Ophthal Plast Reconstr Surg
, vol.11
, pp. 95-99
-
-
Jordan, D.R.1
Allen, L.H.2
Ells, A.3
-
20
-
-
0037244786
-
The use of vicryl mesh in 200 porous orbital implants: a technique with few exposures
-
D.R. Jordan S.R. Klapper S.M. Gilberg The use of vicryl mesh in 200 porous orbital implants: a technique with few exposures Ophthal Plast Reconstr Surg 19 2003 53 61
-
(2003)
Ophthal Plast Reconstr Surg
, vol.19
, pp. 53-61
-
-
Jordan, D.R.1
Klapper, S.R.2
Gilberg, S.M.3
-
21
-
-
0036021169
-
A comparison of rates of fibrovascular ingrowth in wrapped versus unwrapped hydroxyapatite spheres in a rabbit model
-
G.S. Gayre W. Lipham J.J. Dutton A comparison of rates of fibrovascular ingrowth in wrapped versus unwrapped hydroxyapatite spheres in a rabbit model Ophthal Plast Reconstr Surg 18 2002 275 280
-
(2002)
Ophthal Plast Reconstr Surg
, vol.18
, pp. 275-280
-
-
Gayre, G.S.1
Lipham, W.2
Dutton, J.J.3
-
22
-
-
0029149405
-
Vicryl-mesh wrap for the implantation of hydroxyapatite orbital implants: an animal model
-
D.R. Jordan A. Ells S. Brownstein Vicryl-mesh wrap for the implantation of hydroxyapatite orbital implants: an animal model Can J Ophthalmol 30 1995 241 246
-
(1995)
Can J Ophthalmol
, vol.30
, pp. 241-246
-
-
Jordan, D.R.1
Ells, A.2
Brownstein, S.3
-
23
-
-
15944371265
-
Exposure of orbital implants wrapped with polyester-urethane after enucleation for advanced retinoblastoma
-
H. Heimann N.E. Bechrakis L.C. Zepeda Exposure of orbital implants wrapped with polyester-urethane after enucleation for advanced retinoblastoma Ophthal Plast Reconstr Surg 21 2005 123 128
-
(2005)
Ophthal Plast Reconstr Surg
, vol.21
, pp. 123-128
-
-
Heimann, H.1
Bechrakis, N.E.2
Zepeda, L.C.3
-
25
-
-
0029025255
-
Current techniques of enucleation: a survey of 5,439 intraorbital implants and a review of the literature
-
A. Hornblass B.S. Biesman J.A. Eviatar Current techniques of enucleation: a survey of 5,439 intraorbital implants and a review of the literature Ophthal Plast Reconstr Surg 11 1995 77 86
-
(1995)
Ophthal Plast Reconstr Surg
, vol.11
, pp. 77-86
-
-
Hornblass, A.1
Biesman, B.S.2
Eviatar, J.A.3
-
26
-
-
0033638760
-
A new titanium peg system for hydroxyapatite orbital implants
-
D.R. Jordan S.R. Klapper A new titanium peg system for hydroxyapatite orbital implants Ophthal Plast Reconstr Surg 16 2000 380 387
-
(2000)
Ophthal Plast Reconstr Surg
, vol.16
, pp. 380-387
-
-
Jordan, D.R.1
Klapper, S.R.2
|