메뉴 건너뛰기




Volumn 17, Issue 4, 2007, Pages 241-244

The Trident constrained acetabular (bipolar) component for recurrent dislocation. New mode of liner failure

Author keywords

Constrained bipolar liner; Recurrent dislocation

Indexed keywords

ANTIBIOTIC AGENT; BONE CEMENT; POLYETHYLENE; TITANIUM;

EID: 39449097598     PISSN: 11207000     EISSN: None     Source Type: Journal    
DOI: 10.5301/HIP.2008.2977     Document Type: Article
Times cited : (5)

References (8)
  • 1
    • 0014438691 scopus 로고
    • The development of a total metal prosthesis for the hip joint from a partial joint replacement
    • Sivash KM. The development of a total metal prosthesis for the hip joint from a partial joint replacement. Reconstr Surg Traumatol 1969; 11: 53-62.
    • (1969) Reconstr Surg Traumatol , vol.11 , pp. 53-62
    • Sivash, K.M.1
  • 2
    • 33745952356 scopus 로고    scopus 로고
    • A constrained acetabular component for recurrent dislocation
    • khan RJ, Fick D, Alakeson R, et al. A constrained acetabular component for recurrent dislocation. J Bone Joint Surg Br 2006; 88: 870-6.
    • (2006) J Bone Joint Surg Br , vol.88 , pp. 870-876
    • khan, R.J.1    Fick, D.2    Alakeson, R.3
  • 3
    • 0031925716 scopus 로고    scopus 로고
    • Failure of a constrained acetabular prosthesis of a total hip arthroplasty. A report of four cases
    • Kaper BP, Bernini PM. Failure of a constrained acetabular prosthesis of a total hip arthroplasty. A report of four cases. J Bone Joint Surg Am 1998; 80: 561-5.
    • (1998) J Bone Joint Surg Am , vol.80 , pp. 561-565
    • Kaper, B.P.1    Bernini, P.M.2
  • 4
    • 0026098872 scopus 로고
    • Preliminary report on the S-ROM constrained acetabular insert: A retrospective clinical experience
    • Lombardi AV Jr, Mallory TH, Kraus TJ, Vaughn BK. Preliminary report on the S-ROM constrained acetabular insert: a retrospective clinical experience. Orthopedics 1991; 14: 297-303.
    • (1991) Orthopedics , vol.14 , pp. 297-303
    • Lombardi Jr, A.V.1    Mallory, T.H.2    Kraus, T.J.3    Vaughn, B.K.4
  • 5
    • 0141924460 scopus 로고    scopus 로고
    • Use of constrained acetabular components for hip instability: An average 10-year follow-up study
    • Bremner BR, Goetz DD, Callaghan JJ, Capello WN, Johnston RC. Use of constrained acetabular components for hip instability: an average 10-year follow-up study. J Arthroplasty 2003; 18 (Suppl 1): S131-7.
    • (2003) J Arthroplasty , vol.18 , Issue.SUPPL. 1
    • Bremner, B.R.1    Goetz, D.D.2    Callaghan, J.J.3    Capello, W.N.4    Johnston, R.C.5
  • 7
    • 0242574966 scopus 로고    scopus 로고
    • The use of a constrained acetabular component to treat instability after total hip arthroplasty
    • Shrader MW, Parvizi J, Lewallen DG. The use of a constrained acetabular component to treat instability after total hip arthroplasty. J Bone Joint Surg Am 2003; 85: 2179-83.
    • (2003) J Bone Joint Surg Am , vol.85 , pp. 2179-2183
    • Shrader, M.W.1    Parvizi, J.2    Lewallen, D.G.3
  • 8
    • 9644304525 scopus 로고    scopus 로고
    • Use of a constrained tripolar acetabular liner to treat intraoperative instability and postoperative dislocation after total hip arthroplasty: A review of our experience
    • Callaghan JJ, O'Rourke MR, Goetz DD, Lewallen DG, Johnston RL, Capello WN. Use of a constrained tripolar acetabular liner to treat intraoperative instability and postoperative dislocation after total hip arthroplasty: a review of our experience. Clin Orthop Relat Res 2004; 429: 117-23.
    • (2004) Clin Orthop Relat Res , vol.429 , pp. 117-123
    • Callaghan, J.J.1    O'Rourke, M.R.2    Goetz, D.D.3    Lewallen, D.G.4    Johnston, R.L.5    Capello, W.N.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.