-
1
-
-
0034107209
-
Development of flexor tendon surgery: twenty-five years of progress
-
Strickland J.W. Development of flexor tendon surgery: twenty-five years of progress. J Hand Surg 25A (2000) 214-235
-
(2000)
J Hand Surg
, vol.25 A
, pp. 214-235
-
-
Strickland, J.W.1
-
2
-
-
0033060265
-
Treatment of flexor tendon injuries: surgeons' perspective
-
Taras J.S., and Lamb M.J. Treatment of flexor tendon injuries: surgeons' perspective. J Hand Ther 2 (1999) 141-148
-
(1999)
J Hand Ther
, vol.2
, pp. 141-148
-
-
Taras, J.S.1
Lamb, M.J.2
-
3
-
-
0021086424
-
Management of acute flexor tendon injuries
-
Strickland J.W. Management of acute flexor tendon injuries. Orthop Clin North Am 4 (1983) 827-849
-
(1983)
Orthop Clin North Am
, vol.4
, pp. 827-849
-
-
Strickland, J.W.1
-
4
-
-
0022189693
-
Suture materials and suture techniques used in tendon repair
-
Ketchum L.D. Suture materials and suture techniques used in tendon repair. Hand Clin 1 (1985) 43-53
-
(1985)
Hand Clin
, vol.1
, pp. 43-53
-
-
Ketchum, L.D.1
-
6
-
-
0036714645
-
Flexor tendon repair and rehabilitation-state of the art in 2002
-
Boyer M.I., Strickland J.W., Engles D.R., Sachar K., and Leversedge F.J. Flexor tendon repair and rehabilitation-state of the art in 2002. J Bone Joint Surg 84A (2002) 1684-1706
-
(2002)
J Bone Joint Surg
, vol.84 A
, pp. 1684-1706
-
-
Boyer, M.I.1
Strickland, J.W.2
Engles, D.R.3
Sachar, K.4
Leversedge, F.J.5
-
7
-
-
0027716716
-
Gap formation after flexor tendon repair in zone II-results with a new controlled motion program
-
Silfverskiold K.L., and May E.J. Gap formation after flexor tendon repair in zone II-results with a new controlled motion program. Scand J Plast Reconstr Surg Hand Surg 4 (1993) 263-268
-
(1993)
Scand J Plast Reconstr Surg Hand Surg
, vol.4
, pp. 263-268
-
-
Silfverskiold, K.L.1
May, E.J.2
-
8
-
-
0028147581
-
Flexor tendon repair in Zone II with a new suture technique and an early mobilization program combining passive and active flexion
-
Silfverskiold K.L., and May E.J. Flexor tendon repair in Zone II with a new suture technique and an early mobilization program combining passive and active flexion. J Hand Surg 19A (1994) 53-60
-
(1994)
J Hand Surg
, vol.19 A
, pp. 53-60
-
-
Silfverskiold, K.L.1
May, E.J.2
-
9
-
-
0027295155
-
Tendon excursions after flexor tendon repair in zone II-results with a new controlled-motion program
-
Silfverskiold K.L., May E.J., and Tornvall A.H. Tendon excursions after flexor tendon repair in zone II-results with a new controlled-motion program. J Hand Surg 18A (1993) 403-410
-
(1993)
J Hand Surg
, vol.18 A
, pp. 403-410
-
-
Silfverskiold, K.L.1
May, E.J.2
Tornvall, A.H.3
-
10
-
-
39349116349
-
USP, Physical Tests: {881} tensile strength
-
The United States Pharmacopeia Convention, Rockville, MD
-
USP, Physical Tests: {881} tensile strength. The United States pharmacopeia (1995), The United States Pharmacopeia Convention, Rockville, MD 1836-1837
-
(1995)
The United States pharmacopeia
, pp. 1836-1837
-
-
-
11
-
-
0024398427
-
An evaluation of suture materials used in tendon surgery
-
Trail I.A., Powell E.S., and Noble J. An evaluation of suture materials used in tendon surgery. J Hand Surg 14B (1989) 422-427
-
(1989)
J Hand Surg
, vol.14 B
, pp. 422-427
-
-
Trail, I.A.1
Powell, E.S.2
Noble, J.3
-
13
-
-
0034949096
-
Comparison of mechanical properties of polyvinylidene fluoride and polypropylene monofilament sutures used for flexor tendon repair
-
Wada A., Kubota H., Hatanaka H., Miura H., and Iwamoto Y. Comparison of mechanical properties of polyvinylidene fluoride and polypropylene monofilament sutures used for flexor tendon repair. J Hand Surg 83B (2001) 212-216
-
(2001)
J Hand Surg
, vol.83 B
, pp. 212-216
-
-
Wada, A.1
Kubota, H.2
Hatanaka, H.3
Miura, H.4
Iwamoto, Y.5
-
14
-
-
0017169203
-
Physical properties of surgical suture materials: stress-strain relationship, stress-relaxation and irreversible elongation
-
Holmlund D.E. Physical properties of surgical suture materials: stress-strain relationship, stress-relaxation and irreversible elongation. Ann Surg 2 (1976) 189-193
-
(1976)
Ann Surg
, vol.2
, pp. 189-193
-
-
Holmlund, D.E.1
-
16
-
-
0019430288
-
Mechanical properties of suture materials: an important characterization
-
Chu C.C. Mechanical properties of suture materials: an important characterization. Ann Surg 3 (1981) 365-371
-
(1981)
Ann Surg
, vol.3
, pp. 365-371
-
-
Chu, C.C.1
-
19
-
-
0020421571
-
Effect of strain rate on tensile strength and strain of surgical suture materials
-
Nilsson T. Effect of strain rate on tensile strength and strain of surgical suture materials. Scand J Plast Reconstr Surg 2 (1982) 97-100
-
(1982)
Scand J Plast Reconstr Surg
, vol.2
, pp. 97-100
-
-
Nilsson, T.1
-
20
-
-
0026674611
-
Characterization of surgical suture materials using dynamic mechanical analysis
-
von Fraunhofer J.A., and Sichina W.J. Characterization of surgical suture materials using dynamic mechanical analysis. Biomaterials 10 (1992) 715-720
-
(1992)
Biomaterials
, vol.10
, pp. 715-720
-
-
von Fraunhofer, J.A.1
Sichina, W.J.2
-
21
-
-
0028355631
-
Mechanical comparison of 10 suture materials before and after in vivo incubation
-
Greenwald D., Shumway S., Albear P., and Gottlieb L. Mechanical comparison of 10 suture materials before and after in vivo incubation. J Surg Res 4 (1994) 372-377
-
(1994)
J Surg Res
, vol.4
, pp. 372-377
-
-
Greenwald, D.1
Shumway, S.2
Albear, P.3
Gottlieb, L.4
-
22
-
-
0031019047
-
Experimental analysis of tensile properties of some suture materials
-
Nobile L., Checchi L., and Monaco G. Experimental analysis of tensile properties of some suture materials. J Mater Sci Mater Med 8 (1997) 53-56
-
(1997)
J Mater Sci Mater Med
, vol.8
, pp. 53-56
-
-
Nobile, L.1
Checchi, L.2
Monaco, G.3
|