메뉴 건너뛰기




Volumn 15, Issue 3, 2008, Pages 934-940

Confirmation of sentinel lymph node identity by analysis of fine-needle biopsy samples using inductively coupled plasma-mass spectrometry

Author keywords

Clinical; Fine needle biopsy; Melanoma; Pathology; Sentinel lymph node

Indexed keywords

ANTIMONY TECHNETIUM SULFIDE TC 99M; DYE;

EID: 39149140698     PISSN: 10689265     EISSN: 15344681     Source Type: Journal    
DOI: 10.1245/s10434-007-9693-0     Document Type: Article
Times cited : (5)

References (30)
  • 1
    • 0026590057 scopus 로고
    • Technical details of intraoperative lymphatic mapping for early stage melanoma
    • Morton DL, Wen D-R, Wong JH, et al. Technical details of intraoperative lymphatic mapping for early stage melanoma. Arch Surg 1992;127:392-9
    • (1992) Arch Surg , vol.127 , pp. 392-9
    • Morton, D.L.1    Wen, D.-R.2    Wong, J.H.3
  • 2
    • 0028052025 scopus 로고
    • The orderly progression of melanoma nodal metastases
    • Reintgen D, Cruse CW, Wells K, et al. The orderly progression of melanoma nodal metastases. Ann Surg 1994;220:759-67
    • (1994) Ann Surg , vol.220 , pp. 759-67
    • Reintgen, D.1    Cruse, C.W.2    Wells, K.3
  • 3
    • 0029038818 scopus 로고
    • Sentinel lymph node status as an indicator of the presence of metastatic melanoma in regional lymph nodes
    • Thompson JF, McCarthy WH, Bosch CMJ, et al. Sentinel lymph node status as an indicator of the presence of metastatic melanoma in regional lymph nodes. Melanoma Res 1995;5:255-60
    • (1995) Melanoma Res , vol.5 , pp. 255-60
    • Thompson, J.F.1    McCarthy, W.H.2    Bosch, C.M.J.3
  • 4
    • 33749053823 scopus 로고    scopus 로고
    • Sentinel-node biopsy or nodal observation in melanoma
    • Morton DL, Thompson JF, Cochran AJ, et al. Sentinel-node biopsy or nodal observation in melanoma. N Engl J Med 2006;355:1307-17
    • (2006) N Engl J Med , vol.355 , pp. 1307-17
    • Morton, D.L.1    Thompson, J.F.2    Cochran, A.J.3
  • 5
    • 33744747914 scopus 로고    scopus 로고
    • Lymphatic mapping and sentinel lymph node biopsy in the management of primary cutaneous melanoma: Report of a single-centre experience
    • Cecchi R, De Gaudio C, Buralli L, Innocenti S. Lymphatic mapping and sentinel lymph node biopsy in the management of primary cutaneous melanoma: report of a single-centre experience. Tumori 2006;92:113-7
    • (2006) Tumori , vol.92 , pp. 113-7
    • Cecchi, R.1    De Gaudio, C.2    Buralli, L.3    Innocenti, S.4
  • 6
    • 0035011887 scopus 로고    scopus 로고
    • Early recurrence after lymphatic mapping and sentinel node biopsy in patients with primary extremity melanoma: A comparison with elective lymph node dissection
    • Clary BM, Mann B, Brady MS, Lewis JJ, Coit DG. Early recurrence after lymphatic mapping and sentinel node biopsy in patients with primary extremity melanoma: a comparison with elective lymph node dissection. Ann Surg Oncol 2001;8:328-37
    • (2001) Ann Surg Oncol , vol.8 , pp. 328-37
    • Clary, B.M.1    Mann, B.2    Brady, M.S.3    Lewis, J.J.4    Coit, D.G.5
  • 7
    • 33744544278 scopus 로고    scopus 로고
    • Sentinel lymph node biopsy: Is it possible to reduce false negative rates by excluding patients with nodular melanoma?
    • Corrigan MA, Coffey JC, O'Sullivan MJ, Fogarty KM, Redmond HP. Sentinel lymph node biopsy: is it possible to reduce false negative rates by excluding patients with nodular melanoma? Surg J R Coll Surg E 2006;4:153-7
    • (2006) Surg J R Coll Surg e , vol.4 , pp. 153-7
    • Corrigan, M.A.1    Coffey, J.C.2    O'Sullivan, M.J.3    Fogarty, K.M.4    Redmond, H.P.5
  • 8
    • 0141872351 scopus 로고    scopus 로고
    • Review and evaluation of sentinel node procedures in 250 melanoma patients with a median follow-up of 6 years
    • Estourgie SH, Nieweg OE, Valdes Olmos RA, Hoefnagel CA, Kroon BBR. Review and evaluation of sentinel node procedures in 250 melanoma patients with a median follow-up of 6 years. Ann Surg Oncol 2003;10:681-8
    • (2003) Ann Surg Oncol , vol.10 , pp. 681-8
    • Estourgie, S.H.1    Nieweg, O.E.2    Valdes Olmos, R.A.3    Hoefnagel, C.A.4    Kroon, B.B.R.5
  • 9
    • 0033009823 scopus 로고    scopus 로고
    • Outcome of patients with melanoma and histologically negative sentinel lymph nodes
    • Gadd MA, Cosimi AB, Yu J, et al. Outcome of patients with melanoma and histologically negative sentinel lymph nodes. Arch Surg 1999;134:381-7
    • (1999) Arch Surg , vol.134 , pp. 381-7
    • Gadd, M.A.1    Cosimi, A.B.2    Yu, J.3
  • 10
    • 0042388428 scopus 로고    scopus 로고
    • Pathologic review of negative sentinel lymph nodes in melanoma patients with regional recurrence: A clinicopathologic study of 1152 patients undergoing sentinel lymph node biopsy
    • Li LX, Scolyer RA, Ka VS, et al. Pathologic review of negative sentinel lymph nodes in melanoma patients with regional recurrence: a clinicopathologic study of 1152 patients undergoing sentinel lymph node biopsy. Am J Surg Pathol 2003;27:1197-202
    • (2003) Am J Surg Pathol , vol.27 , pp. 1197-202
    • Li, L.X.1    Scolyer, R.A.2    Ka, V.S.3
  • 11
    • 24944441877 scopus 로고    scopus 로고
    • Sentinel node biopsy for early-stage melanoma: Accuracy and morbidity in MSLT-I, an international multicenter trial
    • Morton DL, Cochran AJ, Thompson JF, et al. Sentinel node biopsy for early-stage melanoma: accuracy and morbidity in MSLT-I, an international multicenter trial. Ann Surg 2005;242:302-11
    • (2005) Ann Surg , vol.242 , pp. 302-11
    • Morton, D.L.1    Cochran, A.J.2    Thompson, J.F.3
  • 12
    • 0037331329 scopus 로고    scopus 로고
    • Sentinel lymph node biopsy in melanoma patients with clinically negative regional lymph nodes-one institution's experience
    • Nowecki ZI, Rutkowski P, Nasierowska-Guttmejer A, Ruka W. Sentinel lymph node biopsy in melanoma patients with clinically negative regional lymph nodes-one institution's experience. Melanoma Res 2002;13:35-43
    • (2002) Melanoma Res , vol.13 , pp. 35-43
    • Nowecki, Z.I.1    Rutkowski, P.2    Nasierowska-Guttmejer, A.3    Ruka, W.4
  • 13
    • 33845733555 scopus 로고    scopus 로고
    • The impact of lymphoscintigraphy technique on the outcome of sentinel node biopsy in 1,313 patients with cutaneous melanoma: An Italian Multicentric Study (SOLISM-IMI)
    • Rossi CR, De Salvo GL, Trifiro G, et al. The impact of lymphoscintigraphy technique on the outcome of sentinel node biopsy in 1,313 patients with cutaneous melanoma: an Italian Multicentric Study (SOLISM-IMI). J Nucl Med 2006;47:234-41
    • (2006) J Nucl Med , vol.47 , pp. 234-41
    • Rossi, C.R.1    De Salvo, G.L.2    Trifiro, G.3
  • 14
    • 0007747103 scopus 로고    scopus 로고
    • Reliability of the sentinel node procedure in melanoma patients: Analysis of failures after long-term follow up
    • Statius Muller MG, Borgstein PJ, Pijpers R, et al. Reliability of the sentinel node procedure in melanoma patients: analysis of failures after long-term follow up. Ann Surg Oncol 2000;7:461-8
    • (2000) Ann Surg Oncol , vol.7 , pp. 461-8
    • Statius Muller, M.G.1    Borgstein, P.J.2    Pijpers, R.3
  • 15
    • 31144465695 scopus 로고    scopus 로고
    • High positive sentinel node identification rate by EORTC melanoma group protocol. Prognostic indicators of metastatic patterns after sentinel node biopsy in melanoma
    • van Akkooi AC, de Wilt JH, Verhoef C, et al. High positive sentinel node identification rate by EORTC melanoma group protocol. Prognostic indicators of metastatic patterns after sentinel node biopsy in melanoma. Eur J Cancer 2006;42:372-80
    • (2006) Eur J Cancer , vol.42 , pp. 372-80
    • Van Akkooi, A.C.1    De Wilt, J.H.2    Verhoef, C.3
  • 16
    • 21244472247 scopus 로고    scopus 로고
    • Outcome in 846 cutaneous melanoma patients from a single center after a negative sentinel node biopsy
    • Yee VSK, Thompson JF, McKinnon JG, Scolyer RA, et al. Outcome in 846 cutaneous melanoma patients from a single center after a negative sentinel node biopsy. Ann Surg Oncol 2005;12:429-39
    • (2005) Ann Surg Oncol , vol.12 , pp. 429-39
    • Yee, V.S.K.1    Thompson, J.F.2    McKinnon, J.G.3    Scolyer, R.A.4
  • 17
    • 0037352245 scopus 로고    scopus 로고
    • Antimony by ICP-MS as a marker for sentinel lymph nodes in melanoma patients
    • Dawson M, Doble P, Beavis A, Li LX, et al. Antimony by ICP-MS as a marker for sentinel lymph nodes in melanoma patients. Analyst 2003;128:217-9
    • (2003) Analyst , vol.128 , pp. 217-9
    • Dawson, M.1    Doble, P.2    Beavis, A.3    Li, L.X.4
  • 18
    • 2942662019 scopus 로고    scopus 로고
    • Failure to remove true sentinel nodes can cause failure of the sentinel node biopsy technique: Evidence from antimony concentrations in false-negative sentinel nodes from melanoma patients
    • 3 Suppl
    • Scolyer RA, Thompson JF, Li LX, et al. Failure to remove true sentinel nodes can cause failure of the sentinel node biopsy technique: evidence from antimony concentrations in false-negative sentinel nodes from melanoma patients. Ann Surg Oncol 2004;11(3 Suppl):174S-8S
    • (2004) Ann Surg Oncol , vol.11
    • Scolyer, R.A.1    Thompson, J.F.2    Li, L.X.3
  • 19
    • 0141976173 scopus 로고    scopus 로고
    • Complications associated with sentinel lymph node biopsy for melanoma
    • Wrightson WR, Wong SL, Edwards MJ, et al. Complications associated with sentinel lymph node biopsy for melanoma. Ann Surg Oncol 2003;10:676-80
    • (2003) Ann Surg Oncol , vol.10 , pp. 676-80
    • Wrightson, W.R.1    Wong, S.L.2    Edwards, M.J.3
  • 21
    • 0242550923 scopus 로고    scopus 로고
    • Cost-effectiveness of sentinel lymph node biopsy in thin melanomas
    • Agnese DM, Abdessalam SF, Burak J, et al. Cost-effectiveness of sentinel lymph node biopsy in thin melanomas. Surgery 2003;134:542-7
    • (2003) Surgery , vol.134 , pp. 542-7
    • Agnese, D.M.1    Abdessalam, S.F.2    Burak, J.3
  • 22
    • 24044551083 scopus 로고    scopus 로고
    • Melanoma metastases in regional lymph nodes are accurately detected by proton magnetic resonance spectroscopy of fine-needle aspirate biopsy samples
    • Stretch JR, Somorjai R, Bourne R, et al. Melanoma metastases in regional lymph nodes are accurately detected by proton magnetic resonance spectroscopy of fine-needle aspirate biopsy samples. Ann Surg Oncol 2005;12:943-9
    • (2005) Ann Surg Oncol , vol.12 , pp. 943-9
    • Stretch, J.R.1    Somorjai, R.2    Bourne, R.3
  • 23
    • 0038516817 scopus 로고    scopus 로고
    • Rapid detection of metastatic melanoma in lymph nodes using proton magnetic resonance spectroscopy of fine needle aspiration biopsy samples
    • Lean CL, Bourne R, Thompson JF, et al. Rapid detection of metastatic melanoma in lymph nodes using proton magnetic resonance spectroscopy of fine needle aspiration biopsy samples. Melanoma Res 2003;13:259-61
    • (2003) Melanoma Res , vol.13 , pp. 259-61
    • Lean, C.L.1    Bourne, R.2    Thompson, J.F.3
  • 25
    • 33749070120 scopus 로고    scopus 로고
    • Sentinel-node biopsy in melanoma
    • Balch CM, Cascinelli N. Sentinel-node biopsy in melanoma. N Engl J Med 2006;355:1370-1
    • (2006) N Engl J Med , vol.355 , pp. 1370-1
    • Balch, C.M.1    Cascinelli, N.2
  • 26
    • 4744347277 scopus 로고    scopus 로고
    • Antimony concentrations in nodal tissue can confirm sentinel node identity
    • Scolyer RA, Thompson JF, Li LX, et al. Antimony concentrations in nodal tissue can confirm sentinel node identity. Mod Pathol 2004;17:1191-7
    • (2004) Mod Pathol , vol.17 , pp. 1191-7
    • Scolyer, R.A.1    Thompson, J.F.2    Li, L.X.3
  • 27
    • 0035423933 scopus 로고    scopus 로고
    • Carbon dye histologically confirms the identity of sentinel lymph nodes in cutaneous melanoma
    • Haigh PI, Lucci A, Turner RR, et al. Carbon dye histologically confirms the identity of sentinel lymph nodes in cutaneous melanoma. Cancer 2001;92:535-41
    • (2001) Cancer , vol.92 , pp. 535-41
    • Haigh, P.I.1    Lucci, A.2    Turner, R.R.3
  • 28
    • 0032810993 scopus 로고    scopus 로고
    • Carbon dye as an adjunct to isosulfan blue dye for sentinel lymph node dissection
    • Lucci A, Turner RR, Morton DL. Carbon dye as an adjunct to isosulfan blue dye for sentinel lymph node dissection. Surgery 1999;126:48-53
    • (1999) Surgery , vol.126 , pp. 48-53
    • Lucci, A.1    Turner, R.R.2    Morton, D.L.3
  • 29
    • 33745237195 scopus 로고    scopus 로고
    • Prognostic significance of molecular staging study of sentinel lymph nodes by reverse transcriptase-polymerase chain reaction for tyrosinase in melanoma patients
    • Mangas C, Hilari JM, Paradelo C, Rex J, et al. Prognostic significance of molecular staging study of sentinel lymph nodes by reverse transcriptase- polymerase chain reaction for tyrosinase in melanoma patients. Ann Surg Oncol 2006;13:910-8
    • (2006) Ann Surg Oncol , vol.13 , pp. 910-8
    • Mangas, C.1    Hilari, J.M.2    Paradelo, C.3    Rex, J.4
  • 30
    • 33947607788 scopus 로고    scopus 로고
    • Detection of tyrosinase mRNA in the sentinel lymph nodes of melanoma patients is not a predictor of short-term disease recurrence
    • Tatlidil C, Parkhill WS, Giacomantonio CA, Greer WL, Morris SF, Walsh NM. Detection of tyrosinase mRNA in the sentinel lymph nodes of melanoma patients is not a predictor of short-term disease recurrence. Mod Pathol 2007;20:427-34
    • (2007) Mod Pathol , vol.20 , pp. 427-34
    • Tatlidil, C.1    Parkhill, W.S.2    Giacomantonio, C.A.3    Greer, W.L.4    Morris, S.F.5    Walsh, N.M.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.