Volumn 8, Issue 1, 2008, Pages 10-22

New control scheme for the wind-driven doubly fed induction generator under normal and abnormal grid voltage conditions

Author keywords

Direct power control; Doubly fed induction generator; Fault ride through; Frequency shaped cost function; Grid voltage unbalance; Linear quadratic regulator; Wind energy

Indexed keywords


EID: 39149087722     PISSN: 15982092     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (12)

References (25)
  • 1
    • 33947642126 scopus 로고    scopus 로고
    • Wind energy powers-That-Be successor generation in globalization
    • March
    • L. Gertmar, L. Liljestrand, and H. Lendenmann," Wind energy powers-That-Be successor generation in globalization," IEEE Trans. On Energy Conversion, vol. 22, no. 1, pp. 13-28, March 2007.
    • (2007) IEEE Trans. On Energy Conversion , vol.22 , Issue.1 , pp. 13-28
    • Gertmar, L.1    Liljestrand, L.2    Lendenmann, H.3
  • 3
    • 0036747177 scopus 로고    scopus 로고
    • Variable speed wind generation using doubly fed wound rotor induction machine: A comparison with alternative scheme
    • Sept
    • R. Datta and V. T. Ranganthan," Variable speed wind generation using doubly fed wound rotor induction machine: a comparison with alternative scheme," IEEE Trans. On Energy Conversion, vol. 17, no. 3, pp. 414-421, Sept. 2002.
    • (2002) IEEE Trans. On Energy Conversion , vol.17 , Issue.3 , pp. 414-421
    • Datta, R.1    Ranganthan, V.T.2
  • 4
    • 0036575603 scopus 로고    scopus 로고
    • Doubly fed induction generator systems for wind turbines
    • May/Jun
    • S. Muller, M. Deicke, and R. W. De Doncker, "Doubly fed induction generator systems for wind turbines," IEEE Ind. Appl. Mag., vol. 8, no. 3, pp. 26-33, May/Jun. 2002.
    • (2002) IEEE Ind. Appl. Mag , vol.8 , Issue.3 , pp. 26-33
    • Muller, S.1    Deicke, M.2    De Doncker, R.W.3
  • 5
    • 0038449472 scopus 로고    scopus 로고
    • Analysis, modeling and control of doubly fed induction generators for wind turbines,
    • Ph. D. dissertation, Chalmers Univ. of Technology, Gothenburg, Sweden
    • A. Peterson, "Analysis, modeling and control of doubly fed induction generators for wind turbines," Ph. D. dissertation, Chalmers Univ. of Technology, Gothenburg, Sweden, 2005.
    • (2005)
    • Peterson, A.1
  • 6
    • 84868062873 scopus 로고    scopus 로고
    • Transient modeling and simulation of wind turbine generator and storage systems
    • Oct
    • C. Abbey, J. Chahwan, M. Gattrell, and G. Joos, "Transient modeling and simulation of wind turbine generator and storage systems," CIGRA Canada, Conf. On Power systems, no. 042, pp. 3-8, Oct. 2006.
    • (2006) CIGRA Canada, Conf. On Power systems , Issue.42 , pp. 3-8
    • Abbey, C.1    Chahwan, J.2    Gattrell, M.3    Joos, G.4
  • 7
    • 0029307617 scopus 로고
    • Torque and reactive power control of a doubly fed induction machine by position sensorless scheme
    • May/Jun
    • L. Xu and C. Wei, "Torque and reactive power control of a doubly fed induction machine by position sensorless scheme," IEEE Trans. On Ind. Appl., vol. 31, no. 3, pp. 636-642, May/Jun. 1995.
    • (1995) IEEE Trans. On Ind. Appl , vol.31 , Issue.3 , pp. 636-642
    • Xu, L.1    Wei, C.2
  • 8
    • 0034228293 scopus 로고    scopus 로고
    • Stator flux oriented control of a doubly fed induction machine with and without position encoder
    • Jul
    • B. Hopfensperger, D. J. Atkinson, and R. A. Lakin, "Stator flux oriented control of a doubly fed induction machine with and without position encoder," Proc. Inst. Elect. Eng., vol. 147, pp. 241-250, Jul. 2000.
    • (2000) Proc. Inst. Elect. Eng , vol.147 , pp. 241-250
    • Hopfensperger, B.1    Atkinson, D.J.2    Lakin, R.A.3
  • 9
    • 8744298400 scopus 로고    scopus 로고
    • Comparison between stator-flux and grid-flux-oriented rotor current control of doubly-fed induction generators
    • Aachen, Germany
    • A. Petersson, L. Harnefors, and T. Thiringer," Comparison between stator-flux and grid-flux-oriented rotor current control of doubly-fed induction generators," in proc. Of PESC'04, pp.482-486, Aachen, Germany, 2004.
    • (2004) proc. Of PESC'04 , pp. 482-486
    • Petersson, A.1    Harnefors, L.2    Thiringer, T.3
  • 10
    • 33947613668 scopus 로고    scopus 로고
    • Control of a doubly fed induction wind generator under unbalanced grid voltage conditions
    • March
    • T. Brekken, and N. Mohan, "Control of a doubly fed induction wind generator under unbalanced grid voltage conditions," IEEE Trans. On Energy Conversion, vol. 22, no. 1, pp-129-135, March 2007.
    • (2007) IEEE Trans. On Energy Conversion , vol.22 , Issue.1 , pp. 129-135
    • Brekken, T.1    Mohan, N.2
  • 11
    • 33947313847 scopus 로고    scopus 로고
    • Dynamic modeling and control of DFIG based wind turbines under unbalanced network conditions
    • March
    • L. Xu and Y. Wang, "Dynamic modeling and control of DFIG based wind turbines under unbalanced network conditions," IEEE Trans. On Power Systems, vol. 22, no. 1, pp 314-323, March 2007.
    • (2007) IEEE Trans. On Power Systems , vol.22 , Issue.1 , pp. 314-323
    • Xu, L.1    Wang, Y.2
  • 12
    • 34748848657 scopus 로고    scopus 로고
    • challenges of integrating large amount of wind power
    • April
    • J. D. Rose and I. A. Hiskens, "challenges of integrating large amount of wind power," 1st Ann. IEEE systems Conf., pp. 259-265, April 2007.
    • (2007) 1st Ann. IEEE systems Conf , pp. 259-265
    • Rose, J.D.1    Hiskens, I.A.2
  • 15
    • 33947430524 scopus 로고    scopus 로고
    • Control of a doubly fed induction generator in a wind turbine during grid fault ride-through
    • D. Xiang, L. Ran, P. J. Tavner, and S. Yang," Control of a doubly fed induction generator in a wind turbine during grid fault ride-through," IEEE Trans. On Energy Conversion, vol. 21, no. 3, pp. 652-662, 2006.
    • (2006) IEEE Trans. On Energy Conversion , vol.21 , Issue.3 , pp. 652-662
    • Xiang, D.1    Ran, L.2    Tavner, P.J.3    Yang, S.4
  • 16
    • 33645003355 scopus 로고    scopus 로고
    • steady state stability analysis of doubly fed induction generators under decoupled P-Q control
    • H. Bankar, C. Lou and B. T. Ooi, "steady state stability analysis of doubly fed induction generators under decoupled P-Q control," IEE Proc. Electric Power Appl., vol. 153, no.. 2, pp. 300-306, 2006.
    • (2006) IEE Proc. Electric Power Appl , vol.153 , Issue.. 2 , pp. 300-306
    • Bankar, H.1    Lou, C.2    Ooi, B.T.3
  • 17
    • 39149083720 scopus 로고    scopus 로고
    • M. Heller and W. Schumacher, 'Stability analysis of doubly-fed induction machines in stator flux reference frame, in Proc. of EPE'97, 2, pp. 707-710, Torndheim, Noway, Sept. 1997.
    • M. Heller and W. Schumacher, 'Stability analysis of doubly-fed induction machines in stator flux reference frame," in Proc. of EPE'97, vol. 2, pp. 707-710, Torndheim, Noway, Sept. 1997.
  • 18
    • 84964345048 scopus 로고    scopus 로고
    • Research of stability of double fed induction motor vector control system
    • Shenyang, China, Aug
    • L. Congwei, W. Haiqing, S. Xudong, and L. Fahai, "Research of stability of double fed induction motor vector control system," in Proc. of ICEMS'01, vol. 2, pp. 1203-1206, Shenyang, China, Aug. 2001.
    • (2001) Proc. of ICEMS'01 , vol.2 , pp. 1203-1206
    • Congwei, L.1    Haiqing, W.2    Xudong, S.3    Fahai, L.4
  • 19
    • 12744262671 scopus 로고    scopus 로고
    • Evaluation of current control methods for wind turbines using doubly fed induction machines
    • A. Petersson, L. Harnefors, and T. Thiringer, "Evaluation of current control methods for wind turbines using doubly fed induction machines," IEEE Trans. On Power Electronics, vol.20, no. 1, pp.227-235, 2005.
    • (2005) IEEE Trans. On Power Electronics , vol.20 , Issue.1 , pp. 227-235
    • Petersson, A.1    Harnefors, L.2    Thiringer, T.3
  • 20
    • 32644431559 scopus 로고    scopus 로고
    • Sensorless control of induction machines - with or without signal injection?
    • Pp, Feb
    • J. Holtz," Sensorless control of induction machines - with or without signal injection? " IEEE Trans. On Industrial Electr., vol. 53, no. 1, Pp. 7-30, Feb. 2006.
    • (2006) IEEE Trans. On Industrial Electr , vol.53 , Issue.1 , pp. 7-30
    • Holtz, J.1
  • 21
    • 0019080250 scopus 로고
    • Frequency shaped cost functionals: Extension of linear quadratic Gaussian design methods
    • N. K. Gupta, "Frequency shaped cost functionals: Extension of linear quadratic Gaussian design methods," J. Guidance Contr., vol. 3, no. 6, 1980.
    • (1980) J. Guidance Contr , vol.3 , Issue.6
    • Gupta, N.K.1
  • 22
    • 39149084019 scopus 로고    scopus 로고
    • An Improved DTC scheme for The AC Drives Based on Optimal Preview Control Technique
    • July
    • Osama S. Ebrahim, Mohamed M. Negm and Mohamed Z. Youssef "An Improved DTC scheme for The AC Drives Based on Optimal Preview Control Technique," ISIE2006, July 2006.
    • (2006) ISIE2006
    • Ebrahim, O.S.1    Negm, M.M.2    Youssef, M.Z.3
  • 23
    • 27944496775 scopus 로고    scopus 로고
    • Experimental investigation of high performance induction motor control based on optimal preview controller
    • Mohamed M. Negm, Mohamed F. Salem and Osama S. Ebrahim, "Experimental investigation of high performance induction motor control based on optimal preview controller," IEEE ICIT '04, Vol. 1, pp. 334-340, 2004.
    • (2004) IEEE ICIT '04 , vol.1 , pp. 334-340
    • Negm, M.M.1    Salem, M.F.2    Ebrahim, O.S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.