1
-
-
1642266882
-
Accuracy of the Justy II Apex Locator in determining working length in simulated horizontal and vertical fractures
-
Azabal M., Garcia-Otero D., and de la Macorra J.C. Accuracy of the Justy II Apex Locator in determining working length in simulated horizontal and vertical fractures. Int Endod J 37 (2004) 174-177
-
(2004)
Int Endod J
, vol.37
, pp. 174-177
-
-
Azabal, M.1
Garcia-Otero, D.2
de la Macorra, J.C.3
-
2
-
-
33749041279
-
Accuracy of three different electronic apex locators in detecting simulated horizontal and vertical root fractures
-
Ebrahim A.K., Wadachi R., and Suda H. Accuracy of three different electronic apex locators in detecting simulated horizontal and vertical root fractures. Aust Endod J 32 (2006) 64-69
-
(2006)
Aust Endod J
, vol.32
, pp. 64-69
-
-
Ebrahim, A.K.1
Wadachi, R.2
Suda, H.3
-
3
-
-
0036651349
-
In vivo determination of root canal length: a preliminary report using the Tri Auto-ZX apex-locating handpiece
-
Grimberg F., Banegas G., Chiacchio L., and Zmener O. In vivo determination of root canal length: a preliminary report using the Tri Auto-ZX apex-locating handpiece. Int Endod J 35 (2002) 590-593
-
(2002)
Int Endod J
, vol.35
, pp. 590-593
-
-
Grimberg, F.1
Banegas, G.2
Chiacchio, L.3
Zmener, O.4
-
4
-
-
0028402339
-
New electronic canal measuring device based on the ratio method
-
Kobayashi C., and Suda H. New electronic canal measuring device based on the ratio method. J Endod 20 (1994) 111-114
-
(1994)
J Endod
, vol.20
, pp. 111-114
-
-
Kobayashi, C.1
Suda, H.2
-
6
-
-
33644589221
-
Accuracy of root length determination using Tri Auto ZX and ProTaper instruments: an in vitro study
-
Carneiro E., Bramante C.M., Picoli F., Letra A., da Silva Neto U.X., and Menezes R. Accuracy of root length determination using Tri Auto ZX and ProTaper instruments: an in vitro study. J Endod 32 (2006) 142-144
-
(2006)
J Endod
, vol.32
, pp. 142-144
-
-
Carneiro, E.1
Bramante, C.M.2
Picoli, F.3
Letra, A.4
da Silva Neto, U.X.5
Menezes, R.6
-
7
-
-
0036484408
-
Accuracy of a new apex locator: an in vitro study
-
Kaufman A.Y., Keila S., and Yoshpe M. Accuracy of a new apex locator: an in vitro study. Int Endod J 35 (2002) 186-192
-
(2002)
Int Endod J
, vol.35
, pp. 186-192
-
-
Kaufman, A.Y.1
Keila, S.2
Yoshpe, M.3
-
9
-
-
0031268020
-
Reliability of different electronic apex locators to detect root perforations in vitro
-
Kaufman A.Y., Fuss Z., Keila S., and Waxenberg S. Reliability of different electronic apex locators to detect root perforations in vitro. Int Endod J 30 (1997) 403-407
-
(1997)
Int Endod J
, vol.30
, pp. 403-407
-
-
Kaufman, A.Y.1
Fuss, Z.2
Keila, S.3
Waxenberg, S.4
-
10
-
-
33745809484
-
The fundamental operating principles of electronic root canal length measurement devices
-
Nekoofar M.H., Ghandi M.M., Hayes S.J., and Dummer P.M. The fundamental operating principles of electronic root canal length measurement devices. Int Endod J 39 (2006) 595-609
-
(2006)
Int Endod J
, vol.39
, pp. 595-609
-
-
Nekoofar, M.H.1
Ghandi, M.M.2
Hayes, S.J.3
Dummer, P.M.4
-
11
-
-
33947130655
-
Influence of embedding media on the assessment of electronic apex locators
-
Baldi J.V., Victorino F.R., Bernardes R.A., et al. Influence of embedding media on the assessment of electronic apex locators. J Endod 33 (2007) 476-479
-
(2007)
J Endod
, vol.33
, pp. 476-479
-
-
Baldi, J.V.1
Victorino, F.R.2
Bernardes, R.A.3
-
12
-
-
0346765851
-
Reliability of Root ZX apex locator tested by an in vitro model
-
(abstract)
-
Kaufman A.Y., and Katz A. Reliability of Root ZX apex locator tested by an in vitro model. (abstract). J Endod 19 (1993) 201
-
(1993)
J Endod
, vol.19
, pp. 201
-
-
Kaufman, A.Y.1
Katz, A.2
-
13
-
-
0036834281
-
A simple model to demonstrate the apex locator
-
Tinaz A.C., Alacam T., and Topuz O. A simple model to demonstrate the apex locator. Int Endod J 35 (2002) 940-945
-
(2002)
Int Endod J
, vol.35
, pp. 940-945
-
-
Tinaz, A.C.1
Alacam, T.2
Topuz, O.3
|