-
1
-
-
0032585608
-
Effect of HMG-CoA reductase inhibitors on coronary artery disease as assessed by electron-beam computed tomography
-
Callister TQ, Raggi P, Cooil B, Lippolis NJ, Russo DJ (1998) Effect of HMG-CoA reductase inhibitors on coronary artery disease as assessed by electron-beam computed tomography. N Engl J Med 339:1972-1978
-
(1998)
N Engl J Med
, vol.339
, pp. 1972-1978
-
-
Callister, T.Q.1
Raggi, P.2
Cooil, B.3
Lippolis, N.J.4
Russo, D.J.5
-
2
-
-
0032929867
-
Progression of coronary artery calcification: A pilot study
-
Maher JE, Bielak LF, Raz JA, Sheedy PF II, Schwartz RS, Peyser PA (1999) Progression of coronary artery calcification: A pilot study. Mayo Clin Proc 74:347-355
-
(1999)
Mayo Clin Proc
, vol.74
, pp. 347-355
-
-
Maher, J.E.1
Bielak, L.F.2
Raz, J.A.3
Sheedy II, P.F.4
Schwartz, R.S.5
Peyser, P.A.6
-
3
-
-
0026346615
-
Comparison of serial quantitative evaluation of calcified coronary artery plaque by ultrafast computed tomography in persons with and without obstructive coronary artery disease
-
Janowitz WR, Agatston AS, Viamonte M Jr (1991) Comparison of serial quantitative evaluation of calcified coronary artery plaque by ultrafast computed tomography in persons with and without obstructive coronary artery disease. Am J Cardiol 68:1-6
-
(1991)
Am J Cardiol
, vol.68
, pp. 1-6
-
-
Janowitz, W.R.1
Agatston, A.S.2
Viamonte Jr., M.3
-
4
-
-
0033931392
-
Detection and quantification of coronary calcification: An update
-
Fischbach R, Heindel W (2000) Detection and quantification of coronary calcification: An update. Rofo 172:407-414
-
(2000)
Rofo
, vol.172
, pp. 407-414
-
-
Fischbach, R.1
Heindel, W.2
-
5
-
-
0025342374
-
Quantification of coronary calcium using ultrafast computed tomography
-
Agatston AS, Janowitz WR, Hildner FJ, Zusmer NR, Viamonte M, Detrano R (1990) Quantification of coronary calcium using ultrafast computed tomography. J Am Coll Cardiol 15:827-832
-
(1990)
J Am Coll Cardiol
, vol.15
, pp. 827-832
-
-
Agatston, A.S.1
Janowitz, W.R.2
Hildner, F.J.3
Zusmer, N.R.4
Viamonte, M.5
Detrano, R.6
-
6
-
-
0031720879
-
Coronary artery disease: Improved reproducibility of calcium scoring with an electron-beam CT volumetric method
-
Callister TQ, Cooil B, Raya SP et al (1998) Coronary artery disease: improved reproducibility of calcium scoring with an electron-beam CT volumetric method. Radiology 208:807-814
-
(1998)
Radiology
, vol.208
, pp. 807-814
-
-
Callister, T.Q.1
Cooil, B.2
Raya, S.P.3
-
7
-
-
0031254189
-
Coronary artery calcium: Alternate methods for accurate and reproducible quantitation
-
Yoon HC, Greaser III LE, Mather R, Sinha S, McNitt-Gray MF, Goldin JG (1997) Coronary artery calcium: Alternate methods for accurate and reproducible quantitation. Acad Radiol 4:666-673
-
(1997)
Acad Radiol
, vol.4
, pp. 666-673
-
-
Yoon, H.C.1
Greaser III, L.E.2
Mather, R.3
Sinha, S.4
McNitt-Gray, M.F.5
Goldin, J.G.6
-
8
-
-
0029859989
-
Detection of coronary calcification with electron-beam computed tomography: Evaluation of interexamination reproducibility and comparison of three image-acquisition protocols
-
Wang SJ, Detrano BC, Secci A et al (1996) Detection of coronary calcification with electron-beam computed tomography: Evaluation of interexamination reproducibility and comparison of three image-acquisition protocols. Am Heart J 132:550-558
-
(1996)
Am Heart J
, vol.132
, pp. 550-558
-
-
Wang, S.J.1
Detrano, B.C.2
Secci, A.3
-
9
-
-
0035863635
-
Variability of repeated coronary artery calcium measurements by electron beam tomography
-
Achenbach S, Ropers D, Mohlenkamp S et al (2001) Variability of repeated coronary artery calcium measurements by electron beam tomography. Am J Cardiology 87:210-213
-
(2001)
Am J Cardiology
, vol.87
, pp. 210-213
-
-
Achenbach, S.1
Ropers, D.2
Mohlenkamp, S.3
-
10
-
-
0034604243
-
American College of Cardiology/American heart association expert consensus document on electron-beam computed tomography for the diagnosis and prognosis of coronary artery disease
-
O'Rourke RA, Brundage BH, Froelicher VF et al (2000) American College of Cardiology/American heart association expert consensus document on electron-beam computed tomography for the diagnosis and prognosis of coronary artery disease. Circulation 102:126-134
-
(2000)
Circulation
, vol.102
, pp. 126-134
-
-
O'Rourke, R.A.1
Brundage, B.H.2
Froelicher, V.F.3
-
11
-
-
23844466709
-
A multi-scanner, multi-manufacture, international standard for the quantification of CAC using cardiac CT (abstr)
-
In: Radiological Society of North America, Oak Brook
-
McCollough CH, Ulzheimer S, Halliburton SS, White RD, Kalender WA (2003) A multi-scanner, multi-manufacture, international standard for the quantification of CAC using cardiac CT (abstr). In: Radiological society of North America scientific assembly and annual meeting program. Radiological Society of North America, Oak Brook, Ill 630-631
-
(2003)
Radiological Society of North America Scientific Assembly and Annual Meeting Program
, vol.3
, pp. 630-631
-
-
McCollough, C.H.1
Ulzheimer, S.2
Halliburton, S.S.3
White, R.D.4
Kalender, W.A.5
-
12
-
-
0036597157
-
Reproducibility of coronary calcium quantification in repeat examinations with retrospectively ECG-gated multisection spiral CT
-
Ohnesorge B, Flohr T, Fischbach R et al (2002) Reproducibility of coronary calcium quantification in repeat examinations with retrospectively ECG-gated multisection spiral CT. Eur Radiol 12:1532-1540
-
(2002)
Eur Radiol
, vol.12
, pp. 1532-1540
-
-
Ohnesorge, B.1
Flohr, T.2
Fischbach, R.3
-
13
-
-
0141743446
-
Coronary artery calcium scoring using ECG-gated multidetector CT: Effect of individually optimized image-reconstruction windows on image quality and measurement reproducibility
-
Van Hoe LR, De Meerleer KG, Leyman PP, Vanhoenacker PK (2003) Coronary artery calcium scoring using ECG-gated multidetector CT: Effect of individually optimized image-reconstruction windows on image quality and measurement reproducibility. AJR 181:1093-1100
-
(2003)
AJR
, vol.181
, pp. 1093-1100
-
-
Van Hoe, L.R.1
De Meerleer, K.G.2
Leyman, P.P.3
Vanhoenacker, P.K.4
-
14
-
-
0345616456
-
Reproducibility of coronary calcium measurements from multidetector computed tomography
-
Daniell AL, Wong ND, Friedman JD et al (2003) Reproducibility of coronary calcium measurements from multidetector computed tomography. J Am Coll Cardiol 41:456A
-
(2003)
J Am Coll Cardiol
, vol.41
-
-
Daniell, A.L.1
Wong, N.D.2
Friedman, J.D.3
-
15
-
-
20044372183
-
Variability of repeated coronary artery calcium measurements by 16-MDCT with retrospective reconstruction
-
Horiguchi J, Yamamoto H, Akiyama Y et al (2005) Variability of repeated coronary artery calcium measurements by 16-MDCT with retrospective reconstruction. AJR 184:1917-1923
-
(2005)
AJR
, vol.184
, pp. 1917-1923
-
-
Horiguchi, J.1
Yamamoto, H.2
Akiyama, Y.3
-
16
-
-
0037903112
-
Assessment of calcium scoring performance in cardiac computed tomography
-
Ulzheimer S, Kalender WA (2003) Assessment of calcium scoring performance in cardiac computed tomography. Eur Radiol 13:484-497
-
(2003)
Eur Radiol
, vol.13
, pp. 484-497
-
-
Ulzheimer, S.1
Kalender, W.A.2
-
17
-
-
33846047810
-
The impact of motion artifacts on the reproducibility of repeated coronary artery calcium measurements
-
Horiguchi J, Fukuda H, Yamamoto H et al (2007) The impact of motion artifacts on the reproducibility of repeated coronary artery calcium measurements. Eur Radiol 17:81-86
-
(2007)
Eur Radiol
, vol.17
, pp. 81-86
-
-
Horiguchi, J.1
Fukuda, H.2
Yamamoto, H.3
-
18
-
-
31044431608
-
Timing on 16-slice scanner and implications for 64-slice cardiac CT: Do you start scanning immediately after breath-hold?
-
Horiguchi J, Shen Y, Hirai N et al (2006) Timing on 16-slice scanner and implications for 64-slice cardiac CT: Do you start scanning immediately after breath-hold? Acad Radiol 13:173-176
-
(2006)
Acad Radiol
, vol.13
, pp. 173-176
-
-
Horiguchi, J.1
Shen, Y.2
Hirai, N.3
-
19
-
-
0037448795
-
Radiation dose in computed tomography of the heart
-
Morin RL, Gerber TC, McCollough CH (2003) Radiation dose in computed tomography of the heart. Circulation 107:917-922
-
(2003)
Circulation
, vol.107
, pp. 917-922
-
-
Morin, R.L.1
Gerber, T.C.2
McCollough, C.H.3
-
20
-
-
0036891972
-
Coronary artery calcium measurement with multi-detector row CT: In vitro assessment of effect of radiation dose
-
Hong C, Bae KT, Pilgram TK, Suh J, Bradley D (2002) Coronary artery calcium measurement with multi-detector row CT: In vitro assessment of effect of radiation dose. Radiology 225:901-906
-
(2002)
Radiology
, vol.225
, pp. 901-906
-
-
Hong, C.1
Bae, K.T.2
Pilgram, T.K.3
Suh, J.4
Bradley, D.5
-
21
-
-
0033653986
-
Sensitivity of two electron beam tomography protocols for the detection and quantification of coronary artery calcium
-
Callister T, Janowitz W, Raggi P (2000) Sensitivity of two electron beam tomography protocols for the detection and quantification of coronary artery calcium. AJR 175:1743-1746
-
(2000)
AJR
, vol.175
, pp. 1743-1746
-
-
Callister, T.1
Janowitz, W.2
Raggi, P.3
-
22
-
-
0142178311
-
Coronary calcification at electron-beam CT: Effect of section thickness on calcium scoring in vitro and in vivo
-
Vliegenthart R, Song B, Hofman A, Witteman JCM, Oudkerk M (2003) Coronary calcification at electron-beam CT: Effect of section thickness on calcium scoring in vitro and in vivo. Radiology 229:520-525
-
(2003)
Radiology
, vol.229
, pp. 520-525
-
-
Vliegenthart, R.1
Song, B.2
Hofman, A.3
Witteman, J.C.M.4
Oudkerk, M.5
-
23
-
-
0034763918
-
Overlapping cross-sections significantly improve the reproducibility of coronary calcium measurements by electron beam tomography: A phantom study
-
Achenbach S, Meissner F, Ropers D et al (2001) Overlapping cross-sections significantly improve the reproducibility of coronary calcium measurements by electron beam tomography: A phantom study. JCAT 25:569-573
-
(2001)
JCAT
, vol.25
, pp. 569-573
-
-
Achenbach, S.1
Meissner, F.2
Ropers, D.3
-
24
-
-
0036789156
-
Reproducibility and accuracy of coronary calcium measurements with multi-detector row versus electron-beam CT
-
Kopp AF, Ohnesorge B, Becker C et al (2002) Reproducibility and accuracy of coronary calcium measurements with multi-detector row versus electron-beam CT. Radiology 225:113-119
-
(2002)
Radiology
, vol.225
, pp. 113-119
-
-
Kopp, A.F.1
Ohnesorge, B.2
Becker, C.3
-
25
-
-
0034953432
-
Improved reproducibility of coronary artery calcium scoring by electron beam tomography with a new electrocardiographic trigger method
-
Mao S, Budoff MJ, Bakhsheshi H, Liu SCK (2001) Improved reproducibility of coronary artery calcium scoring by electron beam tomography with a new electrocardiographic trigger method. Invest Radiol 36:363-367
-
(2001)
Invest Radiol
, vol.36
, pp. 363-367
-
-
Mao, S.1
Budoff, M.J.2
Bakhsheshi, H.3
Liu, S.C.K.4
-
26
-
-
0034833834
-
Spiral versus electron-beam CT for coronary artery calcium scoring
-
Goldin JG, Yoon HC, Greaser III LE et al (2001) Spiral versus electron-beam CT for coronary artery calcium scoring. Radiology 221:213-221
-
(2001)
Radiology
, vol.221
, pp. 213-221
-
-
Goldin, J.G.1
Yoon, H.C.2
Greaser III, L.E.3
-
27
-
-
27544487582
-
Effect of varying slice thickness on coronary calcium scoring with multislice computed tomography in vitro and in
-
Muhlenbruch G, Thomas G, Wildberger JE et al (2005) Effect of varying slice thickness on coronary calcium scoring with multislice computed tomography in vitro and in vivo. Invest Radiol 40:695-699
-
(2005)
Vivo. Invest Radiol
, vol.40
, pp. 695-699
-
-
Muhlenbruch, G.1
Thomas, G.2
Wildberger, J.E.3
-
28
-
-
0036242437
-
Coronary artery calcium: Absolute quantification in nonenhanced and contrast-enhanced multidetector row CT studies
-
Hong C, Becker CR, Schoepf UJ et al (2002) Coronary artery calcium: absolute quantification in nonenhanced and contrast-enhanced multidetector row CT studies. Radiology 223:474-480
-
(2002)
Radiology
, vol.223
, pp. 474-480
-
-
Hong, C.1
Becker, C.R.2
Schoepf, U.J.3
-
29
-
-
0037372884
-
Sensitivity to detect small coronary artery calcium lesions with varying slice thickness using electron beam tomography
-
Mao S, Child J, Carson S et al (2003) Sensitivity to detect small coronary artery calcium lesions with varying slice thickness using electron beam tomography. Invest Radiol 38:183-187
-
(2003)
Invest Radiol
, vol.38
, pp. 183-187
-
-
Mao, S.1
Child, J.2
Carson, S.3
-
30
-
-
31444454358
-
Electron beam CT versus 16-slice spiral CT: How accurately can we measure coronary artery calcium volume?
-
Horiguchi J, Shen Y, Akiyama Y et al (2006) Electron beam CT versus 16-slice spiral CT: How accurately can we measure coronary artery calcium volume? Eur Radiol 16:374-380
-
(2006)
Eur Radiol
, vol.16
, pp. 374-380
-
-
Horiguchi, J.1
Shen, Y.2
Akiyama, Y.3
-
31
-
-
33846460389
-
The accuracy of 1- and 3-mm slices in coronary calcium scoring using multi-slice CT in vitro and in vivo
-
Mühlenbruch G, Klotz E, Wildberger JE et al (2007) The accuracy of 1- and 3-mm slices in coronary calcium scoring using multi-slice CT in vitro and in vivo. Eur Radiol 17:321-329
-
(2007)
Eur Radiol
, vol.17
, pp. 321-329
-
-
Mühlenbruch, G.1
Klotz, E.2
Wildberger, J.E.3
-
32
-
-
0037254248
-
Radiation exposure during cardiac CT: Effective doses at multi-detector CT and electron-beam CT
-
Hunold P, Vogt FM, Schmermund A et al (2003) Radiation exposure during cardiac CT: Effective doses at multi-detector CT and electron-beam CT. Radiology 226:145-152
-
(2003)
Radiology
, vol.226
, pp. 145-152
-
-
Hunold, P.1
Vogt, F.M.2
Schmermund, A.3
-
33
-
-
0028087673
-
Small lesions in the heart identified at electron beam CT: Calcification or noise?
-
Bielak LF, Kaufmann RB, Moll PP, MacCollough CH, Schwartz RS, Sheedy PF II (1994) Small lesions in the heart identified at electron beam CT: calcification or noise? Radiology 192:631-636
-
(1994)
Radiology
, vol.192
, pp. 631-636
-
-
Bielak, L.F.1
Kaufmann, R.B.2
Moll, P.P.3
MacCollough, C.H.4
Schwartz, R.S.5
Sheedy II, P.F.6
|