메뉴 건너뛰기




Volumn 13, Issue 2, 2008, Pages 109-115

Different pattern of fluid loss from the lower extremities in normohydrated and overhydrated stage 5 chronic-kidney-disease patients after haemodialysis

Author keywords

Body fluid; Chronic kidney failure; Electric impedance; Renal dialysis

Indexed keywords

ADULT; AGED; ARTICLE; BIOENERGY; BODY FLUID COMPARTMENT; BODY WATER; CHRONIC KIDNEY DISEASE; CLINICAL ARTICLE; CORRELATION COEFFICIENT; DEHYDRATION; EXTRACELLULAR FLUID; FEMALE; HEMODIALYSIS; HEMODIALYSIS PATIENT; HUMAN; IMPEDANCE; INTRACELLULAR FLUID; LEG; MALE; PRIORITY JOURNAL; TOTAL BODY WATER; ULTRAFILTRATION;

EID: 38949178405     PISSN: 13205358     EISSN: 14401797     Source Type: Journal    
DOI: 10.1111/j.1440-1797.2007.00832.x     Document Type: Article
Times cited : (3)

References (36)
  • 1
    • 0032936433 scopus 로고    scopus 로고
    • Assessment of dry weight in hemodialysis: An overview
    • Jaeger JQ, Mehta RL. Assessment of dry weight in hemodialysis: An overview. J. Am. Soc. Nephrol. 1999 10 : 392 403.
    • (1999) J. Am. Soc. Nephrol. , vol.10 , pp. 392-403
    • Jaeger, J.Q.1    Mehta, R.L.2
  • 2
    • 84960600145 scopus 로고
    • Echography of the inferior vena cava is a simple and reliable tool for estimation of 'dry weight' in hemodialysis patients
    • Cheriex EC, Leunissen KML, Janssen JHA, Mooy JMV, Van Hoof JP. Echography of the inferior vena cava is a simple and reliable tool for estimation of 'dry weight' in hemodialysis patients. Nephrol. Dial. Transplant. 1989 4 : 563 8.
    • (1989) Nephrol. Dial. Transplant. , vol.4 , pp. 563-8
    • Cheriex, E.C.1    Leunissen, K.M.L.2    Janssen, J.H.A.3    Mooy, J.M.V.4    Van Hoof, J.P.5
  • 3
    • 0021886305 scopus 로고
    • Atrial natriuretic peptide in plasma of volume-overloaded children with chronic renal failure
    • Rascher W, Tulassay T, Lang RE. Atrial natriuretic peptide in plasma of volume-overloaded children with chronic renal failure. Lancet 1985 2 : 303 5.
    • (1985) Lancet , vol.2 , pp. 303-5
    • Rascher, W.1    Tulassay, T.2    Lang, R.E.3
  • 4
    • 0026831734 scopus 로고
    • The postdialytic plasma cyclic guanosine 3′5′-monophosphate level as a measure of fluid overload in chronic haemodialysis
    • Lauster F, Fulle HJ, Gerzer R, Schiffl H. The postdialytic plasma cyclic guanosine 3′5′-monophosphate level as a measure of fluid overload in chronic haemodialysis. J. Am. Soc. Nephrol. 1992 2 : 1451 4.
    • (1992) J. Am. Soc. Nephrol. , vol.2 , pp. 1451-4
    • Lauster, F.1    Fulle, H.J.2    Gerzer, R.3    Schiffl, H.4
  • 5
    • 0030476408 scopus 로고    scopus 로고
    • Multifrequency bioimpedance in assessment of dry weight in haemodialysis
    • Katzarski K, Charra B, Laurent G et al. Multifrequency bioimpedance in assessment of dry weight in haemodialysis. Nephrol. Dial. Transplant. 1996 11 (Suppl 2 20 23.
    • (1996) Nephrol. Dial. Transplant. , vol.11 , Issue.SUPPL. 2 , pp. 20-23
    • Katzarski, K.1    Charra, B.2    Laurent, G.3
  • 6
    • 0027381935 scopus 로고
    • Non-invasive monitoring of blood volume during hemodialysis: Its relation with post-dialytic dry weight
    • De Vries JPPM, Kouw PM, van der Meer NJM. Non-invasive monitoring of blood volume during hemodialysis: Its relation with post-dialytic dry weight. Kidney Int. 1993 44 : 851 4.
    • (1993) Kidney Int. , vol.44 , pp. 851-4
    • De Vries Jppm1    Kouw, P.M.2    Van Der Meer, N.J.M.3
  • 7
    • 28444449425 scopus 로고    scopus 로고
    • 2 for predicting body weight: Crude indicator for dry weight in haemodialysis patients
    • 2 for predicting body weight: Crude indicator for dry weight in haemodialysis patients. Nephrology 2005 10 : 446 52.
    • (2005) Nephrology , vol.10 , pp. 446-52
    • Lee, S.W.1    Park, G.H.2    Lee, S.Y.3    Song, J.H.4    Kim, M.J.5
  • 8
    • 0031432253 scopus 로고    scopus 로고
    • Total body water and body composition in chronic peritoneal dialysis patients
    • Arkouche W, Fouque D, Pachiaudi C et al. Total body water and body composition in chronic peritoneal dialysis patients. J. Am. Soc. Nephrol. 1997 8 : 1906 14.
    • (1997) J. Am. Soc. Nephrol. , vol.8 , pp. 1906-14
    • Arkouche, W.1    Fouque, D.2    Pachiaudi, C.3
  • 9
    • 0031031070 scopus 로고    scopus 로고
    • Assessment of total body water and lean body mass from anthropometry, Watson formula, creatinine kinetics, and body electrical impedance compared with antipyrine kinetics in peritoneal dialysis patients
    • de Fijter WM, de Fijter CWH, Oe PL, ter Wee PM, Donker AJM. Assessment of total body water and lean body mass from anthropometry, Watson formula, creatinine kinetics, and body electrical impedance compared with antipyrine kinetics in peritoneal dialysis patients. Nephrol. Dial. Transplant. 1997 12 : 151 6.
    • (1997) Nephrol. Dial. Transplant. , vol.12 , pp. 151-6
    • De Fijter, W.M.1    De Fijter, C.W.H.2    Oe, P.L.3    Ter Wee, P.M.4    Donker, A.J.M.5
  • 12
    • 0028139354 scopus 로고
    • Bioimpedance analysis of total body water in hemodialysis patients
    • Ho T, Kushner R, Schoeller D, Gudivaka R, Spiegel D. Bioimpedance analysis of total body water in hemodialysis patients. Kidney Int. 1994 46 : 1438 42.
    • (1994) Kidney Int. , vol.46 , pp. 1438-42
    • Ho, T.1    Kushner, R.2    Schoeller, D.3    Gudivaka, R.4    Spiegel, D.5
  • 13
    • 84943010051 scopus 로고    scopus 로고
    • Bioelectrical impedance measurement: Errors and artifacts
    • Di Iorio BR, Terracciano V, Bellizzi V. Bioelectrical impedance measurement: Errors and artifacts. J. Ren. Nutr. 1999 9 : 192 7.
    • (1999) J. Ren. Nutr. , vol.9 , pp. 192-7
    • Di Iorio, B.R.1    Terracciano, V.2    Bellizzi, V.3
  • 14
    • 0030978220 scopus 로고    scopus 로고
    • Effect of postural changes on the reliability of volume estimations from bioimpedance spectroscopy data
    • Scharfetter H, Monif M, Laszlo Z, Lambauer T, Hutten H, Hinghofer-Szalkay H. Effect of postural changes on the reliability of volume estimations from bioimpedance spectroscopy data. Kidney Int. 1997 51 : 1078 87.
    • (1997) Kidney Int. , vol.51 , pp. 1078-87
    • Scharfetter, H.1    Monif, M.2    Laszlo, Z.3    Lambauer, T.4    Hutten, H.5    Hinghofer-Szalkay, H.6
  • 15
    • 0036856469 scopus 로고    scopus 로고
    • Accuracy of an eight-point tactile-electrode impedance method in the assessment of total body water
    • Bedogni G, Malavolti M, Severi S et al. Accuracy of an eight-point tactile-electrode impedance method in the assessment of total body water. Eur. J. Clin. Nutr. 2002 56 : 1143 8.
    • (2002) Eur. J. Clin. Nutr. , vol.56 , pp. 1143-8
    • Bedogni, G.1    Malavolti, M.2    Severi, S.3
  • 16
    • 0019152162 scopus 로고
    • Symptomatic hypotension during hemodialysis
    • Henderson LW. Symptomatic hypotension during hemodialysis. Kidney Int. 1980 17 : 571 6.
    • (1980) Kidney Int. , vol.17 , pp. 571-6
    • Henderson, L.W.1
  • 17
    • 0027688501 scopus 로고
    • Second generation logarithmic estimates of single-pool variable volume Kt/V: An analysis of error
    • Daugirdas JT. Second generation logarithmic estimates of single-pool variable volume Kt/V: An analysis of error. J. Am. Soc. Nephrol. 1993 4 : 1205 13.
    • (1993) J. Am. Soc. Nephrol. , vol.4 , pp. 1205-13
    • Daugirdas, J.T.1
  • 18
    • 38949192840 scopus 로고    scopus 로고
    • A study of the nutritional status and its related factors in the elderly hemodialysis patients
    • Park KA, Sim YM, Kim SB, Choi S. A study of the nutritional status and its related factors in the elderly hemodialysis patients. Korean J. Nutr. 2006 39 : 133 44.
    • (2006) Korean J. Nutr. , vol.39 , pp. 133-44
    • Park, K.A.1    Sim, Y.M.2    Kim, S.B.3    Choi, S.4
  • 19
    • 38949176331 scopus 로고    scopus 로고
    • Ministry of Health and Welfare, Republic of Korea. Seoul: Ministry of Health and Welfare
    • Ministry of Health and Welfare, Republic of Korea. 2005 National Health and Nutrition Survery - Final Report. Seoul : Ministry of Health and Welfare, 2006.
    • (2006) 2005 National Health and Nutrition Survery - Final Report.
  • 20
    • 0037707055 scopus 로고    scopus 로고
    • Cross-calibration of eight-polar bioelectrical impedance analysis versus dual-energy X-ray absorptiometry for the assessment of total and appendicular body composition in healthy subjects aged 21-82 years
    • Malavolti M, Mussi C, Poli M et al. Cross-calibration of eight-polar bioelectrical impedance analysis versus dual-energy X-ray absorptiometry for the assessment of total and appendicular body composition in healthy subjects aged 21-82 years. Ann. Hum. Biol. 2003 30 : 380 91.
    • (2003) Ann. Hum. Biol. , vol.30 , pp. 380-91
    • Malavolti, M.1    Mussi, C.2    Poli, M.3
  • 21
    • 0035162645 scopus 로고    scopus 로고
    • Preserving central blood volume: Changes in body fluid compartments during hemodialysis
    • Shulman T, Heidenheim AP, Kianfar C, Shulman SM, Lindsay RM. Preserving central blood volume: Changes in body fluid compartments during hemodialysis. ASAIO J. 2001 47 : 615 18.
    • (2001) ASAIO J. , vol.47 , pp. 615-18
    • Shulman, T.1    Heidenheim, A.P.2    Kianfar, C.3    Shulman, S.M.4    Lindsay, R.M.5
  • 22
    • 0030012199 scopus 로고    scopus 로고
    • Assessment of excess fluid distribution in chronic hemodialysis patients using bioimpedance spectroscopy
    • Fisch BJ, Spiegel DM. Assessment of excess fluid distribution in chronic hemodialysis patients using bioimpedance spectroscopy. Kidney Int. 1996 49 : 1105 9.
    • (1996) Kidney Int. , vol.49 , pp. 1105-9
    • Fisch, B.J.1    Spiegel, D.M.2
  • 23
    • 0035990557 scopus 로고    scopus 로고
    • Age effects on body fluid distribution during exercise in the heat
    • Morgan AL, Sinning WE, Weldy DL. Age effects on body fluid distribution during exercise in the heat. Aviat. Space Environ. Med. 2002 73 : 750 57.
    • (2002) Aviat. Space Environ. Med. , vol.73 , pp. 750-57
    • Morgan, A.L.1    Sinning, W.E.2    Weldy, D.L.3
  • 24
    • 1842503926 scopus 로고    scopus 로고
    • Adjustment of dry weight in hemodialysis patients using intradialytic continuous multifrequency bioimpedance of the calf
    • Zhu F, Kuhlmann MK, Sarkar S et al. Adjustment of dry weight in hemodialysis patients using intradialytic continuous multifrequency bioimpedance of the calf. Int. J. Artif. Organs. 2004 12 : 104 9.
    • (2004) Int. J. Artif. Organs. , vol.12 , pp. 104-9
    • Zhu, F.1    Kuhlmann, M.K.2    Sarkar, S.3
  • 25
    • 0038439449 scopus 로고    scopus 로고
    • Plasma brain natriuretic peptide concentrations in end-stage renal disease patients on hemodialysis
    • Lee SW, Song JH, Kim KA, Lim HJ, Kim MJ. Plasma brain natriuretic peptide concentrations in end-stage renal disease patients on hemodialysis. Am. J. Kidney Dis. 2003 41 : 1257 66.
    • (2003) Am. J. Kidney Dis. , vol.41 , pp. 1257-66
    • Lee, S.W.1    Song, J.H.2    Kim, K.A.3    Lim, H.J.4    Kim, M.J.5
  • 26
    • 0033972819 scopus 로고    scopus 로고
    • Bioimpedance resistance ratios for the evaluation of dry weight in hemodialysis
    • Spiegel DM, Bashir K, Fisch B. Bioimpedance resistance ratios for the evaluation of dry weight in hemodialysis. Clin. Nephrol. 2000 53 : 108 14.
    • (2000) Clin. Nephrol. , vol.53 , pp. 108-14
    • Spiegel, D.M.1    Bashir, K.2    Fisch, B.3
  • 27
    • 38949216331 scopus 로고    scopus 로고
    • Evaluation of ultrafiltration adequacy by segmental multifrequency bioimpedance analysis (BIA) in patients with maintenance hemodialysis (HD)
    • (In Korean.)
    • Choi KB. Evaluation of ultrafiltration adequacy by segmental multifrequency bioimpedance analysis (BIA) in patients with maintenance hemodialysis (HD). Korean J. Nephrol. 1999 18 : 322 8. (In Korean.)
    • (1999) Korean J. Nephrol. , vol.18 , pp. 322-8
    • Choi, K.B.1
  • 28
    • 0031928649 scopus 로고    scopus 로고
    • Dynamics of segmental extracellular volumes during changes in body position by bioimpedance analysis
    • Zhu F, Schneditz D, Wang E, Levin NW. Dynamics of segmental extracellular volumes during changes in body position by bioimpedance analysis. J. Appl. Physiol. 1998 85 : 497 504.
    • (1998) J. Appl. Physiol. , vol.85 , pp. 497-504
    • Zhu, F.1    Schneditz, D.2    Wang, E.3    Levin, N.W.4
  • 31
    • 0032807622 scopus 로고    scopus 로고
    • Sum of segmental bioimpedance analysis during ultrafiltration and hemodialysis reduces sensitivity to changes in body position
    • Zhu F, Schneditz D, Levin NW. Sum of segmental bioimpedance analysis during ultrafiltration and hemodialysis reduces sensitivity to changes in body position. Kidney Int. 1999 56 : 692 9.
    • (1999) Kidney Int. , vol.56 , pp. 692-9
    • Zhu, F.1    Schneditz, D.2    Levin, N.W.3
  • 32
    • 0347517836 scopus 로고    scopus 로고
    • Extracellular and intracellular volume variations during postural change measured by segmental and wrist-ankle bioimpedance spectroscopy
    • Fenech M, Jaffrin MY. Extracellular and intracellular volume variations during postural change measured by segmental and wrist-ankle bioimpedance spectroscopy. IEEE Trans. Biomed. Eng. 2004 51 : 166 75.
    • (2004) IEEE Trans. Biomed. Eng. , vol.51 , pp. 166-75
    • Fenech, M.1    Jaffrin, M.Y.2
  • 34
    • 2542492371 scopus 로고    scopus 로고
    • A systematic evaluation of bioelectrical impedance measurement after hemodialysis session
    • Di Iorio BR, Scalfi L, Terraciano V, Bellizzi V. A systematic evaluation of bioelectrical impedance measurement after hemodialysis session. Kidney Int. 2004 65 : 2435 40.
    • (2004) Kidney Int. , vol.65 , pp. 2435-40
    • Di Iorio, B.R.1    Scalfi, L.2    Terraciano, V.3    Bellizzi, V.4
  • 36
    • 23944525350 scopus 로고    scopus 로고
    • Accuracy of eight-polar bioelectrical impedance analysis for the assessment of total and appendicular body composition in peritoneal dialysis patients
    • Medici G, Mussi C, Fantuzzi AL, Malavolti M, Albertazzi A, Bedogni G. Accuracy of eight-polar bioelectrical impedance analysis for the assessment of total and appendicular body composition in peritoneal dialysis patients. Eur. J. Clin. Nutr. 2005 59 : 932 7.
    • (2005) Eur. J. Clin. Nutr. , vol.59 , pp. 932-7
    • Medici, G.1    Mussi, C.2    Fantuzzi, A.L.3    Malavolti, M.4    Albertazzi, A.5    Bedogni, G.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.