메뉴 건너뛰기




Volumn 10, Issue 2, 2008, Pages 69-80

Continuous glucose monitoring and diabetes health outcomes: A critical appraisal

Author keywords

[No Author keywords available]

Indexed keywords

GLYCOSYLATED HEMOGLOBIN; HEMOGLOBIN A1C; INSULIN;

EID: 38949154486     PISSN: 15209156     EISSN: None     Source Type: Journal    
DOI: 10.1089/dia.2007.0261     Document Type: Review
Times cited : (39)

References (60)
  • 1
    • 33744467412 scopus 로고    scopus 로고
    • Determinants of glycaemic control in type 1 diabetes during intensified therapy with multiple daily insulin injections or continuous subcutaneous insulin infusion: Importance of blood glucose variability
    • Pickup JC, Kidd J, Burmiston S, Yemane N: Determinants of glycaemic control in type 1 diabetes during intensified therapy with multiple daily insulin injections or continuous subcutaneous insulin infusion: importance of blood glucose variability. Diabetes Metab Res Rev 2006;22:232-237.
    • (2006) Diabetes Metab Res Rev , vol.22 , pp. 232-237
    • Pickup, J.C.1    Kidd, J.2    Burmiston, S.3    Yemane, N.4
  • 2
    • 18144415490 scopus 로고    scopus 로고
    • Should minimal blood glucose variability become the gold standard of glycemic control
    • Hirsch IB, Brownlee M: Should minimal blood glucose variability become the gold standard of glycemic control. J Diabetes Complications 2005;19:178-181.
    • (2005) J Diabetes Complications , vol.19 , pp. 178-181
    • Hirsch, I.B.1    Brownlee, M.2
  • 3
    • 33645745733 scopus 로고    scopus 로고
    • Activation of oxidative stress by acute glucose fluctuations compared with sustained chronic hyperglycemia
    • Monnier L, Mas E, Ginet C, Michel F, Villon L, Cristol JP, Colette C: Activation of oxidative stress by acute glucose fluctuations compared with sustained chronic hyperglycemia. JAMA 2006; 295:1681-1687.
    • (2006) JAMA , vol.295 , pp. 1681-1687
    • Monnier, L.1    Mas, E.2    Ginet, C.3    Michel, F.4    Villon, L.5    Cristol, J.P.6    Colette, C.7
  • 4
    • 33746460818 scopus 로고    scopus 로고
    • The effect of glucose variability on the risk of microvascular complications in type 1 diabetes
    • Kilpatrick ES, Rigby AS, Atkin SL: The effect of glucose variability on the risk of microvascular complications in type 1 diabetes. Diabetes Care 2006;29:1486-1490.
    • (2006) Diabetes Care , vol.29 , pp. 1486-1490
    • Kilpatrick, E.S.1    Rigby, A.S.2    Atkin, S.L.3
  • 5
    • 0026465961 scopus 로고
    • Fear of hypoglycemia: Relationship to physical and psychological symptoms in patients with insulin-dependent diabetes mellitus
    • Irvine AA, Cox D, Gonder-Frederick L: Fear of hypoglycemia: relationship to physical and psychological symptoms in patients with insulin-dependent diabetes mellitus. Health Psychol 1992;11:135-138.
    • (1992) Health Psychol , vol.11 , pp. 135-138
    • Irvine, A.A.1    Cox, D.2    Gonder-Frederick, L.3
  • 8
    • 0027370108 scopus 로고
    • The effect of intensive treatment of diabetes on the development and progression of long-term complications in insulin-dependent diabetes mellitus
    • The Diabetes Control and Complications Trial Research Group
    • The Diabetes Control and Complications Trial Research Group: The effect of intensive treatment of diabetes on the development and progression of long-term complications in insulin-dependent diabetes mellitus. N Engl J Med 1993;329:977-986.
    • (1993) N Engl J Med , vol.329 , pp. 977-986
  • 10
    • 33644664033 scopus 로고    scopus 로고
    • Mechanisms of hypoglycemia-associated autonomic failure and its component syndromes in diabetes
    • Cryer PE: Mechanisms of hypoglycemia-associated autonomic failure and its component syndromes in diabetes. Diabetes 2005;54:3592-3601.
    • (2005) Diabetes , vol.54 , pp. 3592-3601
    • Cryer, P.E.1
  • 11
    • 4143122170 scopus 로고    scopus 로고
    • Morbidity of hypoglycemia in type 1 diabetes
    • Frier BM: Morbidity of hypoglycemia in type 1 diabetes. Diabetes Res Clin Pract 2004;65(Suppl 1):S47-S52.
    • (2004) Diabetes Res Clin Pract , vol.65 , Issue.SUPPL. 1
    • Frier, B.M.1
  • 12
    • 0027409534 scopus 로고
    • Frequency and morbidity of severe hypoglycemia in insulin-treated diabetic patients
    • MacLeod KM, Hepburn DA, Frier BM: Frequency and morbidity of severe hypoglycemia in insulin-treated diabetic patients. Diabet Med 1993;10:238-245.
    • (1993) Diabet Med , vol.10 , pp. 238-245
    • MacLeod, K.M.1    Hepburn, D.A.2    Frier, B.M.3
  • 13
    • 0028648289 scopus 로고
    • Hypoglycemia, the most feared complication of insulin therapy
    • McCrimmon RJ, Frier BM: Hypoglycemia, the most feared complication of insulin therapy. Diabetes Metab 1994;20:503-512.
    • (1994) Diabetes Metab , vol.20 , pp. 503-512
    • McCrimmon, R.J.1    Frier, B.M.2
  • 14
    • 0036015959 scopus 로고    scopus 로고
    • Calibration of a subcutaneous amperometric glucose sensor implanted for 7 days in diabetic patients. Part 1. Effect of measurement uncertainties on the determination of sensor sensitivity and background current
    • Choleau C, Klein JC, Reach G, Aussedat B, Demaria-Pesce V, Wilson GS, Gifford R, Ward WK: Calibration of a subcutaneous amperometric glucose sensor implanted for 7 days in diabetic patients. Part 1. Effect of measurement uncertainties on the determination of sensor sensitivity and background current. Biosens Bioelectron 2002;17:641-646.
    • (2002) Biosens Bioelectron , vol.17 , pp. 641-646
    • Choleau, C.1    Klein, J.C.2    Reach, G.3    Aussedat, B.4    Demaria-Pesce, V.5    Wilson, G.S.6    Gifford, R.7    Ward, W.K.8
  • 15
    • 0043025558 scopus 로고    scopus 로고
    • Physiological differences between interstitial glucose and blood glucose measured in human subjects
    • Kulcu E, Tamada JA, Reach G, Potts RO, Lesho MJ: Physiological differences between interstitial glucose and blood glucose measured in human subjects. Diabetes Care 2003;26:2405-2409.
    • (2003) Diabetes Care , vol.26 , pp. 2405-2409
    • Kulcu, E.1    Tamada, J.A.2    Reach, G.3    Potts, R.O.4    Lesho, M.J.5
  • 16
    • 33748436855 scopus 로고    scopus 로고
    • Evaluation of the accuracy of a microdialysis-based glucose sensor during insulin-induced hypoglycemia, its recovery, and post-hypoglycemic hyperglycemia in humans
    • Rossetti P, Porcellati F, Fanelli CG, Bolli GB: Evaluation of the accuracy of a microdialysis-based glucose sensor during insulin-induced hypoglycemia, its recovery, and post-hypoglycemic hyperglycemia in humans. Diabetes Technol Ther 2006;8:326-337.
    • (2006) Diabetes Technol Ther , vol.8 , pp. 326-337
    • Rossetti, P.1    Porcellati, F.2    Fanelli, C.G.3    Bolli, G.B.4
  • 17
    • 0242300559 scopus 로고    scopus 로고
    • Timing of changes in interstitial and venous blood glucose measured with a continuous subcutaneous glucose sensor
    • Boyne MS, Silver DM, Kaplan J, Saudek CD: Timing of changes in interstitial and venous blood glucose measured with a continuous subcutaneous glucose sensor. Diabetes 2003;52:2790-2794.
    • (2003) Diabetes , vol.52 , pp. 2790-2794
    • Boyne, M.S.1    Silver, D.M.2    Kaplan, J.3    Saudek, C.D.4
  • 19
    • 0041666413 scopus 로고    scopus 로고
    • Clinical performance of CGMS in type 1 diabetic patients treated by continuous subcutaneous insulin infusion using insulin analogs
    • Guerci B, Floriot M, Böhme P, Durain D, Benichou M, Jellimann S, Drouin P: Clinical performance of CGMS in type 1 diabetic patients treated by continuous subcutaneous insulin infusion using insulin analogs. Diabetes Care 2003;26:582-589.
    • (2003) Diabetes Care , vol.26 , pp. 582-589
    • Guerci, B.1    Floriot, M.2    Böhme, P.3    Durain, D.4    Benichou, M.5    Jellimann, S.6    Drouin, P.7
  • 20
    • 38949198112 scopus 로고    scopus 로고
    • King A, Armstrong D, Chu C, Sharma M, Price D: Use of multiple CGMS sensors shows agreement in glucose values but significant difference in rates of glucose change [abstract]. Diabetes 2007;56(Suppl 1):85-OR.
    • King A, Armstrong D, Chu C, Sharma M, Price D: Use of multiple CGMS sensors shows agreement in glucose values but significant difference in rates of glucose change [abstract]. Diabetes 2007;56(Suppl 1):85-OR.
  • 21
    • 38949129864 scopus 로고    scopus 로고
    • Zisser H, Shwartz S, Ratner R, Wise J, Bailey T: Accuracy of seven-day continuous glucose sensor compared to YSI blood glucose values [abstract]. Diabetes 2007;56(Suppl 1):92-OR.
    • Zisser H, Shwartz S, Ratner R, Wise J, Bailey T: Accuracy of seven-day continuous glucose sensor compared to YSI blood glucose values [abstract]. Diabetes 2007;56(Suppl 1):92-OR.
  • 22
    • 25844437994 scopus 로고    scopus 로고
    • Nocturnal differences in subcutaneous tissue glucose between forearm and abdominal sites during continuous glucose monitoring in normal subjects
    • Von Dobeln A, Adamson U: Nocturnal differences in subcutaneous tissue glucose between forearm and abdominal sites during continuous glucose monitoring in normal subjects. Diabetes Metab 2005;31:347-352.
    • (2005) Diabetes Metab , vol.31 , pp. 347-352
    • Von Dobeln, A.1    Adamson, U.2
  • 23
    • 3342981187 scopus 로고    scopus 로고
    • Evaluating the accuracy of continuous glucose-monitoring sensors: Continuous glucose-error grid analysis illustrated by TheraSense Freestyle Navigator data
    • Kovatchev BP, Gonder-Frederick LA, Cox DJ, Clarke WL: Evaluating the accuracy of continuous glucose-monitoring sensors: continuous glucose-error grid analysis illustrated by TheraSense Freestyle Navigator data. Diabetes Care 2004;27:1922-1928.
    • (2004) Diabetes Care , vol.27 , pp. 1922-1928
    • Kovatchev, B.P.1    Gonder-Frederick, L.A.2    Cox, D.J.3    Clarke, W.L.4
  • 24
    • 33748412631 scopus 로고    scopus 로고
    • Evaluation of factors affecting CGMS calibration
    • Diabetes in Research Children Network (DirecNet) Study Group
    • Diabetes in Research Children Network (DirecNet) Study Group: Evaluation of factors affecting CGMS calibration. Diabetes Technol Ther 2006;8:318-325.
    • (2006) Diabetes Technol Ther , vol.8 , pp. 318-325
  • 25
    • 0042668344 scopus 로고    scopus 로고
    • Hypoglycemia prevalence in prepubertal children with type 1 diabetes on standard insulin regimen: Use of continuous glucose monitoring system
    • Amin E, Ross K, Acerini CL, Edge JA, Warner J, Dunger DB: Hypoglycemia prevalence in prepubertal children with type 1 diabetes on standard insulin regimen: use of continuous glucose monitoring system. Diabetes Care 2003;26:662-667.
    • (2003) Diabetes Care , vol.26 , pp. 662-667
    • Amin, E.1    Ross, K.2    Acerini, C.L.3    Edge, J.A.4    Warner, J.5    Dunger, D.B.6
  • 26
    • 0036728499 scopus 로고    scopus 로고
    • Spurious reporting of nocturnal hypoglycemia by CGMS in patients with tightly controlled type 1 diabetes
    • McGowan K, Thomas W, Moran A: Spurious reporting of nocturnal hypoglycemia by CGMS in patients with tightly controlled type 1 diabetes. Diabetes Care 2002;1499-1503.
    • (2002) Diabetes Care , pp. 1499-1503
    • McGowan, K.1    Thomas, W.2    Moran, A.3
  • 27
    • 21244434882 scopus 로고    scopus 로고
    • Eight-point glucose testing versus the continuous glucose monitoring system in evaluation of glycemic control in type 1 diabetes
    • Diabetes in Research Children Network (DirecNet) Study Group
    • Diabetes in Research Children Network (DirecNet) Study Group: Eight-point glucose testing versus the continuous glucose monitoring system in evaluation of glycemic control in type 1 diabetes. J Clin Endocrinol Metab 2005;90:3387-3391.
    • (2005) J Clin Endocrinol Metab , vol.90 , pp. 3387-3391
  • 28
    • 17144416158 scopus 로고    scopus 로고
    • What is hypoglycemia in patients with well-controlled type 1 diabetes treated by subcutaneous insulin pump with use of the continuous glucose monitoring system?
    • Larsen J, Ford T, Lyde E, Colling C, Mack-Shipman L, Lane J: What is hypoglycemia in patients with well-controlled type 1 diabetes treated by subcutaneous insulin pump with use of the continuous glucose monitoring system? Endocr Pract 2004;10:324-329.
    • (2004) Endocr Pract , vol.10 , pp. 324-329
    • Larsen, J.1    Ford, T.2    Lyde, E.3    Colling, C.4    Mack-Shipman, L.5    Lane, J.6
  • 29
    • 0032754795 scopus 로고    scopus 로고
    • Continuous glucose monitoring used to adjust diabetes therapy improves glycosylated hemoglobin: A pilot study
    • Bode BW, Gross TM, Thornton KR, Mastrototaro JJ: Continuous glucose monitoring used to adjust diabetes therapy improves glycosylated hemoglobin: a pilot study. Diabetes Res Clin Pract 1999;46:183-190.
    • (1999) Diabetes Res Clin Pract , vol.46 , pp. 183-190
    • Bode, B.W.1    Gross, T.M.2    Thornton, K.R.3    Mastrototaro, J.J.4
  • 31
    • 0035656734 scopus 로고    scopus 로고
    • A pilot study of the continuous glucose monitoring system: Clinical decisions and glycemic control after its use in pediatric type 1 diabetic subjects
    • Kaufman FR, Gibson LC, Halvorson M, Carpenter S, Fisher LK, Pitukcheewanont P: A pilot study of the continuous glucose monitoring system: clinical decisions and glycemic control after its use in pediatric type 1 diabetic subjects. Diabetes Care 2001;24:2030-2034.
    • (2001) Diabetes Care , vol.24 , pp. 2030-2034
    • Kaufman, F.R.1    Gibson, L.C.2    Halvorson, M.3    Carpenter, S.4    Fisher, L.K.5    Pitukcheewanont, P.6
  • 32
    • 0345862180 scopus 로고    scopus 로고
    • Improved metabolic control in diabetic adolescents using the continuous glucose monitoring system (CGMS)
    • Schaepelynck-Belicar P, Vague Ph, Simonin G, Lassmann-Vague V: Improved metabolic control in diabetic adolescents using the continuous glucose monitoring system (CGMS). Diabetes Metab 2003;29:608-612.
    • (2003) Diabetes Metab , vol.29 , pp. 608-612
    • Schaepelynck-Belicar, P.1    Vague, P.2    Simonin, G.3    Lassmann-Vague, V.4
  • 34
    • 0034939686 scopus 로고    scopus 로고
    • Self-monitoring of blood glucose levels and glycemic control: The Northern California Kaiser Permanente Diabetes Registry
    • Karter AJ, Ackerson LM, Darbinian JA, D'Agostino RB Jr, Ferrara A, Liu J, Selby JV: Self-monitoring of blood glucose levels and glycemic control: the Northern California Kaiser Permanente Diabetes Registry. Am J Med 2001;111:1-9.
    • (2001) Am J Med , vol.111 , pp. 1-9
    • Karter, A.J.1    Ackerson, L.M.2    Darbinian, J.A.3    D'Agostino Jr, R.B.4    Ferrara, A.5    Liu, J.6    Selby, J.V.7
  • 35
    • 9644275397 scopus 로고    scopus 로고
    • Use of the Continuous Glucose Monitoring System to guide therapy in patients with insulin-treated diabetes: A randomized controlled trial
    • Tanenberg R, Bode B, Lane W, Levetan C, Mestman J, Harmel AP, Tobian J, Gross T, Mastrototaro J: Use of the Continuous Glucose Monitoring System to guide therapy in patients with insulin-treated diabetes: a randomized controlled trial. Mayo Clin Proc 2004;79:1521-1526.
    • (2004) Mayo Clin Proc , vol.79 , pp. 1521-1526
    • Tanenberg, R.1    Bode, B.2    Lane, W.3    Levetan, C.4    Mestman, J.5    Harmel, A.P.6    Tobian, J.7    Gross, T.8    Mastrototaro, J.9
  • 37
    • 0042490765 scopus 로고    scopus 로고
    • The continuous glucose monitoring system is useful for detecting unrecognized hypoglycemias in patients with type 1 and type 2 diabetes but is not better than frequent capillary glucose measurements for improving metabolic control
    • Chico A, Vidal-Rios P, Subira M, Novials A: The continuous glucose monitoring system is useful for detecting unrecognized hypoglycemias in patients with type 1 and type 2 diabetes but is not better than frequent capillary glucose measurements for improving metabolic control. Diabetes Care 2003;26:1153-1157.
    • (2003) Diabetes Care , vol.26 , pp. 1153-1157
    • Chico, A.1    Vidal-Rios, P.2    Subira, M.3    Novials, A.4
  • 38
    • 33746393341 scopus 로고    scopus 로고
    • Continuous glucose monitoring-guided insulin adjustment in children and adolescents on near-physiological insulin regimens: A randomized controlled trial
    • Yates K,Milton AH, Dear K, Ambler G: Continuous glucose monitoring-guided insulin adjustment in children and adolescents on near-physiological insulin regimens: a randomized controlled trial. Diabetes Care 2006;29:1512-1517.
    • (2006) Diabetes Care , vol.29 , pp. 1512-1517
    • Yates, K.1    Milton, A.H.2    Dear, K.3    Ambler, G.4
  • 39
    • 33745249928 scopus 로고    scopus 로고
    • Continuous subcutaneous glucose monitoring in children with type 1 diabetes mellitus: A single-blind, randomized, controlled trial
    • Lagarde WH, Barrows FP, Davenport ML, Kang M, Guess HA, Calikoglu AS: Continuous subcutaneous glucose monitoring in children with type 1 diabetes mellitus: a single-blind, randomized, controlled trial. Pediatr Diabetes 2006;7:159-164.
    • (2006) Pediatr Diabetes , vol.7 , pp. 159-164
    • Lagarde, W.H.1    Barrows, F.P.2    Davenport, M.L.3    Kang, M.4    Guess, H.A.5    Calikoglu, A.S.6
  • 40
    • 0038643466 scopus 로고    scopus 로고
    • Continuous subcutaneous glucose monitoring improved metabolic control in pediatric patients with type 1 diabetes: A controlled crossover study
    • Ludvigsson J, Hanas R: Continuous subcutaneous glucose monitoring improved metabolic control in pediatric patients with type 1 diabetes: a controlled crossover study. Pediatrics 2003;111:933-938.
    • (2003) Pediatrics , vol.111 , pp. 933-938
    • Ludvigsson, J.1    Hanas, R.2
  • 41
    • 33645455629 scopus 로고    scopus 로고
    • Results of a randomised controlled cross-over trial on the effect of continuous subcutaneous glucose monitoring (CGMS) on glycaemic control in children and adolescents with type 1 diabetes
    • Deiss D, Hartman R, Schmidt J, Kordonouri O: Results of a randomised controlled cross-over trial on the effect of continuous subcutaneous glucose monitoring (CGMS) on glycaemic control in children and adolescents with type 1 diabetes. Exp Clin Endocrinol Diabetes 2006;114:63-67.
    • (2006) Exp Clin Endocrinol Diabetes , vol.114 , pp. 63-67
    • Deiss, D.1    Hartman, R.2    Schmidt, J.3    Kordonouri, O.4
  • 43
    • 18144373420 scopus 로고    scopus 로고
    • A randomized multicenter trial comparing the GlucoWatch Biographer with standard glucose monitoring in children with type 1 diabetes
    • The Diabetes Research in Children Network (DirecNet) Study Group
    • The Diabetes Research in Children Network (DirecNet) Study Group: A randomized multicenter trial comparing the GlucoWatch Biographer with standard glucose monitoring in children with type 1 diabetes. Diabetes Care 2005;28:1101-1106.
    • (2005) Diabetes Care , vol.28 , pp. 1101-1106
  • 44
    • 1442324399 scopus 로고    scopus 로고
    • Improved glucose excursions using an implantable real-time continuous glucose sensor in adults with type 1 diabetes
    • Garg SK, Schwartz S, Edelman SV: Improved glucose excursions using an implantable real-time continuous glucose sensor in adults with type 1 diabetes. Diabetes Care 2004;27:734-738.
    • (2004) Diabetes Care , vol.27 , pp. 734-738
    • Garg, S.K.1    Schwartz, S.2    Edelman, S.V.3
  • 45
    • 33644875792 scopus 로고    scopus 로고
    • Improvement in glycemic excursions with a transcutaneous, real-time continuous glucose sensor: A randomized controlled trial
    • Garg SK, Zisser H, Schwartz S, Bailey T, Kaplan R, Ellis S, Jovanovic L: Improvement in glycemic excursions with a transcutaneous, real-time continuous glucose sensor: a randomized controlled trial. Diabetes Care 2006;29:44-50.
    • (2006) Diabetes Care , vol.29 , pp. 44-50
    • Garg, S.K.1    Zisser, H.2    Schwartz, S.3    Bailey, T.4    Kaplan, R.5    Ellis, S.6    Jovanovic, L.7
  • 46
    • 33845475479 scopus 로고    scopus 로고
    • Relationship of fasting and hourly blood glucose levels to HbA1c values: Safety, accuracy, and improvements in glucose profiles obtained using a 7-day continuous glucose sensor
    • Garg SK, Jovanovic L: Relationship of fasting and hourly blood glucose levels to HbA1c values: safety, accuracy, and improvements in glucose profiles obtained using a 7-day continuous glucose sensor. Diabetes Care 2006;29:2644-2649.
    • (2006) Diabetes Care , vol.29 , pp. 2644-2649
    • Garg, S.K.1    Jovanovic, L.2
  • 47
    • 34250776500 scopus 로고    scopus 로고
    • Reduction in hemoglobin A1c with real-time continuous glucose monitoring: Results from a 12-week observational study
    • Bailey TS, Zisser HC, Garg SK: Reduction in hemoglobin A1c with real-time continuous glucose monitoring: results from a 12-week observational study. Diabetes Technol Ther 2007;9:299-306.
    • (2007) Diabetes Technol Ther , vol.9 , pp. 299-306
    • Bailey, T.S.1    Zisser, H.C.2    Garg, S.K.3
  • 48
    • 33845483509 scopus 로고    scopus 로고
    • Improved glycemic control in poorly controlled patients with type 1 diabetes using real-time continuous glucose monitoring
    • Deiss D, Bolinder J, Riveline JP, Battelino T, Bosi E, Tubiana-Rufi N, Kerr D, Philip M: Improved glycemic control in poorly controlled patients with type 1 diabetes using real-time continuous glucose monitoring, Diabetes Care 2006;29:2730-2732.
    • (2006) Diabetes Care , vol.29 , pp. 2730-2732
    • Deiss, D.1    Bolinder, J.2    Riveline, J.P.3    Battelino, T.4    Bosi, E.5    Tubiana-Rufi, N.6    Kerr, D.7    Philip, M.8
  • 50
    • 20044380573 scopus 로고    scopus 로고
    • Continuous glucose monitoring in interstitial subcutaneous adipose tissue and skeletal muscle reflects excursions in cerebral cortex
    • Nielsen JK, Djurhuus CB, Gravholt CH, Carus AC, Granild-Jensen J, Orskov H, Christiansen JS: Continuous glucose monitoring in interstitial subcutaneous adipose tissue and skeletal muscle reflects excursions in cerebral cortex. Diabetes 2005;54:1635-1639.
    • (2005) Diabetes , vol.54 , pp. 1635-1639
    • Nielsen, J.K.1    Djurhuus, C.B.2    Gravholt, C.H.3    Carus, A.C.4    Granild-Jensen, J.5    Orskov, H.6    Christiansen, J.S.7
  • 51
    • 38949212778 scopus 로고    scopus 로고
    • Hirsch IB, Bode BW, Abelseth J, Fischer JS, Kaufman FR, Mastrototaro J, Wolpert HA, Buckingham BA: Sensor augmented pump therapy: results of the first treat-to-target study [abstract]. Diabetes 2007;56(Suppl 1):90-OR.
    • Hirsch IB, Bode BW, Abelseth J, Fischer JS, Kaufman FR, Mastrototaro J, Wolpert HA, Buckingham BA: Sensor augmented pump therapy: results of the first treat-to-target study [abstract]. Diabetes 2007;56(Suppl 1):90-OR.
  • 53
    • 1442275324 scopus 로고    scopus 로고
    • Accuracy of the GlucoWatch G2 Biographer and the continuous glucose monitoring system during hypoglycemia: Experience of the Diabetes Research in Children Network
    • Diabetes Research in Children Network (DirecNet) Study Group
    • Diabetes Research in Children Network (DirecNet) Study Group: Accuracy of the GlucoWatch G2 Biographer and the continuous glucose monitoring system during hypoglycemia: experience of the Diabetes Research in Children Network. Diabetes Care 2004;27:722-726.
    • (2004) Diabetes Care , vol.27 , pp. 722-726
  • 54
    • 33646692450 scopus 로고    scopus 로고
    • Psychological aspects of continuous glucose monitoring in pediatric type 1 diabetes
    • Diabetes Research in Children Network (DirecNet) Study Group
    • Diabetes Research in Children Network (DirecNet) Study Group: Psychological aspects of continuous glucose monitoring in pediatric type 1 diabetes. Pediatr Diabetes 2006;7:32-38.
    • (2006) Pediatr Diabetes , vol.7 , pp. 32-38
  • 55
    • 33646050618 scopus 로고    scopus 로고
    • Value and limitations of the Continuous Glucose Monitoring System in the management of type 1 diabetes
    • Melki V, Ayon F, Fernandez M, Hanaire-Broutin H: Value and limitations of the Continuous Glucose Monitoring System in the management of type 1 diabetes. Diabetes Metab 2006;32:123-129.
    • (2006) Diabetes Metab , vol.32 , pp. 123-129
    • Melki, V.1    Ayon, F.2    Fernandez, M.3    Hanaire-Broutin, H.4
  • 56
    • 4544226876 scopus 로고    scopus 로고
    • Day-to-day glucose variability during pregnancy in women with Type 1 diabetes mellitus: Glucose profiles measured with the Continuous Glucose Monitoring System
    • Kerssen A, de Valk HW, Visser GH: Day-to-day glucose variability during pregnancy in women with Type 1 diabetes mellitus: glucose profiles measured with the Continuous Glucose Monitoring System. BJOG 2004;111:919-924.
    • (2004) BJOG , vol.111 , pp. 919-924
    • Kerssen, A.1    de Valk, H.W.2    Visser, G.H.3
  • 57
    • 0019779372 scopus 로고
    • Algorithms for adjustment of insulin dosage by patients who monitor blood glucose
    • Skyler JS, Skyler DL, Seigler DE, O'Sullivan MJ: Algorithms for adjustment of insulin dosage by patients who monitor blood glucose. Diabetes Care 1981;4:311-318.
    • (1981) Diabetes Care , vol.4 , pp. 311-318
    • Skyler, J.S.1    Skyler, D.L.2    Seigler, D.E.3    O'Sullivan, M.J.4
  • 58
    • 38949162016 scopus 로고    scopus 로고
    • Accessed January 8, 2008
    • http://clinicaltrials.gov/ct/show/NCT00406133?order=1. Accessed January 8, 2008.
  • 59
    • 34249940466 scopus 로고    scopus 로고
    • Meta-analysis does not allow appraisal of complex interventions in diabetes and hypertension self-management: A methodological review
    • Lenz M, Steckelberg A, Richter B, Mühlhauser I: Meta-analysis does not allow appraisal of complex interventions in diabetes and hypertension self-management: a methodological review. Diabetologia 2007;50:1375-1383.
    • (2007) Diabetologia , vol.50 , pp. 1375-1383
    • Lenz, M.1    Steckelberg, A.2    Richter, B.3    Mühlhauser, I.4
  • 60
    • 33845447377 scopus 로고    scopus 로고
    • Flexible intensive insulin therapy in adults with type 1 diabetes and high risk for severe hypoglycemia and diabetic ketoacidosis
    • Sämann A, Mühlhauser I, Bender R, Hunger-Dathe W, Kloos C, Müller UA: Flexible intensive insulin therapy in adults with type 1 diabetes and high risk for severe hypoglycemia and diabetic ketoacidosis. Diabetes Care 2006;29:2196-2199.
    • (2006) Diabetes Care , vol.29 , pp. 2196-2199
    • Sämann, A.1    Mühlhauser, I.2    Bender, R.3    Hunger-Dathe, W.4    Kloos, C.5    Müller, U.A.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.