메뉴 건너뛰기




Volumn 19, Issue 3, 2008, Pages

A study of resolution function on a MIEZE spectrometer

Author keywords

Ferrofluid; MIEZE; Resolution function

Indexed keywords

MAGNETIC FLUIDS; MONTE CARLO METHODS; NEUTRONS; OPTICAL RESOLVING POWER; SCATTERING; SIGNAL ANALYSIS;

EID: 38949132501     PISSN: 09570233     EISSN: 13616501     Source Type: Journal    
DOI: 10.1088/0957-0233/19/3/034006     Document Type: Conference Paper
Times cited : (12)

References (11)
  • 1
    • 0000205155 scopus 로고
    • A high resolution neutron spectrometer for quasielastic scattering on the basis of spin-echo and magnetic resonance
    • Gähler and Golub R 1987 A high resolution neutron spectrometer for quasielastic scattering on the basis of spin-echo and magnetic resonance Z. Phys. B 65 269
    • (1987) Z. Phys. , vol.65 , Issue.3 , pp. 269
    • Gähler1    Golub, R.2
  • 2
    • 44049115073 scopus 로고
    • Neutron resonance spin echo-a new tool for high resolution spectroscopy
    • Gähler R, Golub R and Keller T 1992 Neutron resonance spin echo-a new tool for high resolution spectroscopy Physica B 180-181 899
    • (1992) Physica , vol.180-181 , pp. 899
    • Gähler, R.1    Golub, R.2    Keller, T.3
  • 3
    • 33751237101 scopus 로고    scopus 로고
    • Neutron resonance spin echo and MIEZE spectrometer development project in Japan
    • Kawabata Y et al 2006 Neutron resonance spin echo and MIEZE spectrometer development project in Japan Physica B 85 1122
    • (2006) Physica , vol.85 , pp. 1122
    • Kawabata, Y.1    Al, E.2
  • 4
    • 34047171621 scopus 로고    scopus 로고
    • Development of a resonance spin flipper for NRSE/MIEZE on a pulsed neutron beam with an oscillating frequency of 500 kHz
    • Hayashida H, Kitaguchi M, Hino M, Kawabata Y, Maruyama R and Ebisawa T 2007 Development of a resonance spin flipper for NRSE/MIEZE on a pulsed neutron beam with an oscillating frequency of 500 kHz Nucl. Instrum. Methods A 530 292
    • (2007) Nucl. Instrum. Methods , vol.574 , Issue.2 , pp. 292
    • Hayashida, H.1    Kitaguchi, M.2    Hino, M.3    Kawabata, Y.4    Maruyama, R.5    Ebisawa, T.6
  • 5
    • 34250613458 scopus 로고    scopus 로고
    • Observation of MIEZE signal with an effective frequency of 1 MHz
    • Hayashida H, Kitaguchi M, Hino M, Kawabata Y and Ebisawa T 2007 Observation of MIEZE signal with an effective frequency of 1 MHz Physica B 397 144
    • (2007) Physica , vol.397 , Issue.1-2 , pp. 144
    • Hayashida, H.1    Kitaguchi, M.2    Hino, M.3    Kawabata, Y.4    Ebisawa, T.5
  • 6
    • 13444273113 scopus 로고    scopus 로고
    • MISANS, a method for quasi-elastic small angle neutron scattering experiments
    • Bleuel M, Littrell K, Gähler R and Lal J 2005 MISANS, a method for quasi-elastic small angle neutron scattering experiments Physica B 356 213
    • (2005) Physica , vol.356 , Issue.1-4 , pp. 213
    • Bleuel, M.1    Littrell, K.2    Gähler, R.3    Lal, J.4
  • 7
    • 33751257508 scopus 로고    scopus 로고
    • A test of MIEZE-reflectometer for study of surface and interface
    • Hino M et al 2006 A test of MIEZE-reflectometer for study of surface and interface Physica B 385 1125
    • (2006) Physica , vol.385 , pp. 1125
    • Hino, M.1    Al, E.2
  • 11
    • 18144413969 scopus 로고    scopus 로고
    • Development of a neutron detector based on a position-sensitive photomultiplier
    • Hirota K et al 2005 Development of a neutron detector based on a position-sensitive photomultiplier Phys. Chem. Chem. Phys. 7 1836
    • (2005) Phys. Chem. Chem. Phys. , vol.7 , Issue.8 , pp. 1836
    • Hirota, K.1    Al, E.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.