메뉴 건너뛰기




Volumn 40, Issue 17, 2007, Pages 3290-3308

The determination of salbutamol sulfat based on a flow-injection coupling irreversible biamperometry at poly(aminosulfonic acid)-modified glassy carbon electrode

Author keywords

Chemical modified electrode; Electrocatalysis oxidation; Eletropolymerization; Flow injection irreversible biamperometry; Glassy carbon electrode; Poly(aminosulfonic acid); Salbutamol sulfat

Indexed keywords


EID: 38949129140     PISSN: 00032719     EISSN: 1532236X     Source Type: Journal    
DOI: 10.1080/00032710701672772     Document Type: Article
Times cited : (20)

References (40)
  • 1
    • 0024656782 scopus 로고
    • Electronically conductive polymer fibers with mesoscopic diameters show enhanced electronic conductivities
    • Cai, Z. and Martin, C.R. 1989. Electronically conductive polymer fibers with mesoscopic diameters show enhanced electronic conductivities. J. Am. Chem. Soc., 111: 4138-4139.
    • (1989) J. Am. Chem. Soc , vol.111 , pp. 4138-4139
    • Cai, Z.1    Martin, C.R.2
  • 2
    • 0023311288 scopus 로고
    • Electrochemical preparation of a ladder polymer containing phenazine rings
    • Chiba, K., Ohsaka, T., Ohnuki, Y., and Oyama, N. 1987. Electrochemical preparation of a ladder polymer containing phenazine rings. J. Electroanal. Chem., 219: 117-124.
    • (1987) J. Electroanal. Chem , vol.219 , pp. 117-124
    • Chiba, K.1    Ohsaka, T.2    Ohnuki, Y.3    Oyama, N.4
  • 3
    • 0005363021 scopus 로고
    • Hexachloroiridate III/IV on polymer coated electrodes: Investigations of the membrane permeability and the charge-transport mechanism
    • Doblhofer, K. and Lang, R. 1987. Hexachloroiridate III/IV on polymer coated electrodes: Investigations of the membrane permeability and the charge-transport mechanism. J. Electroanal. Chem., 229: 239.
    • (1987) J. Electroanal. Chem , vol.229 , pp. 239
    • Doblhofer, K.1    Lang, R.2
  • 4
    • 38949129042 scopus 로고    scopus 로고
    • HPLC determination of salbutatool sulfate in its compound suppositories
    • Dongqing, L., Yanhua, T., Baoquan, C., and Meixian, Y. 2005. HPLC determination of salbutatool sulfate in its compound suppositories. Chin. J. Pharm. Anal., 25 (6): 709-712.
    • (2005) Chin. J. Pharm. Anal , vol.25 , Issue.6 , pp. 709-712
    • Dongqing, L.1    Yanhua, T.2    Baoquan, C.3    Meixian, Y.4
  • 5
    • 16344378341 scopus 로고    scopus 로고
    • Electrocatalysis of L-Cysteine-modified Gold Electrode to o-Benzeuediol and p-Benzeuediol and its application
    • Du, D., Wang, S.F., and Huang, C.B. 2001. Electrocatalysis of L-Cysteine-modified Gold Electrode to o-Benzeuediol and p-Benzeuediol and its application. Journal of Instrumental Analysis, 20 (5): 18-20.
    • (2001) Journal of Instrumental Analysis , vol.20 , Issue.5 , pp. 18-20
    • Du, D.1    Wang, S.F.2    Huang, C.B.3
  • 6
    • 0023951551 scopus 로고    scopus 로고
    • Determination of albulerol in human serum by reversed-phase high-performance liquid chromatography with electrochemical detection
    • Erum, T., Lesko, L.J., and Leslie, J. 1998. Determination of albulerol in human serum by reversed-phase high-performance liquid chromatography with electrochemical detection. J. Chromatogram., 427 (1): 188-198.
    • (1998) J. Chromatogram , vol.427 , Issue.1 , pp. 188-198
    • Erum, T.1    Lesko, L.J.2    Leslie, J.3
  • 7
    • 0023177533 scopus 로고
    • Comparative steady state bioavailability of conventional and controlled-release for mulations of albuterol
    • Fowell, M.L., Weisberger, M., and Dowdy, Y. 1987. Comparative steady state bioavailability of conventional and controlled-release for mulations of albuterol. Biopharm. Drug Dispos., 8: 461-468.
    • (1987) Biopharm. Drug Dispos , vol.8 , pp. 461-468
    • Fowell, M.L.1    Weisberger, M.2    Dowdy, Y.3
  • 8
    • 17744362464 scopus 로고    scopus 로고
    • Determination of salbutamol, amikacin, and paromomycin sulfate by a novel sulfate polymeric membrane sensor based on 2,6-diphenyl 4-(4-methoxyphenyl) pyrylium perchlorate
    • Ganjali, M.R., Sepehri, A., Daftari, A., Norouzil, P., Pirelahi, H., and Moradzadegan, A. 2005. Determination of salbutamol, amikacin, and paromomycin sulfate by a novel sulfate polymeric membrane sensor based on 2,6-diphenyl 4-(4-methoxyphenyl) pyrylium perchlorate. Microchim. Acta, 149: 245-249.
    • (2005) Microchim. Acta , vol.149 , pp. 245-249
    • Ganjali, M.R.1    Sepehri, A.2    Daftari, A.3    Norouzil, P.4    Pirelahi, H.5    Moradzadegan, A.6
  • 9
    • 38949107281 scopus 로고    scopus 로고
    • Investigation of oxygen reduction at platinum loaded poly(o-phenylenediamine) electrode in acid medium
    • Gajendran, P., Vijayanand, S., and Saraswathi, R. 2006. Investigation of oxygen reduction at platinum loaded poly(o-phenylenediamine) electrode in acid medium. J. Electroanal. Chem., 56: 751-762.
    • (2006) J. Electroanal. Chem , vol.56 , pp. 751-762
    • Gajendran, P.1    Vijayanand, S.2    Saraswathi, R.3
  • 10
    • 0021860192 scopus 로고
    • Electroanalysis with chemically modified electrodes
    • Guadalupe, A.R. and Abruna, H.D. 1985. Electroanalysis with chemically modified electrodes. Anal. Chem., 57: 142-149.
    • (1985) Anal. Chem , vol.57 , pp. 142-149
    • Guadalupe, A.R.1    Abruna, H.D.2
  • 11
    • 18544364476 scopus 로고    scopus 로고
    • Poly(p-aminobenzene sulfonic acid)-modified glassy carbon electrode for simultaneous detection of dopamine and ascorbic acid
    • Guiying, Jin, Yuzhong, Zhang, and Wangxing, Cheng. 2005. Poly(p-aminobenzene sulfonic acid)-modified glassy carbon electrode for simultaneous detection of dopamine and ascorbic acid. Sensor Actuator B, 107: 528-534.
    • (2005) Sensor Actuator B , vol.107 , pp. 528-534
    • Jin, G.1    Zhang, Y.2    Cheng, W.3
  • 12
    • 4644270580 scopus 로고
    • Thermochemistry of aqueous aminosulfonic acids: Sulfamic and sulfanilic acids and taurine
    • Hopkins, H.P. Jr., Wu, C.-H., and Hepler, L.G. 1964. Thermochemistry of aqueous aminosulfonic acids: sulfamic and sulfanilic acids and taurine. J. Chem. Phys., 41: 2244-2248.
    • (1964) J. Chem. Phys , vol.41 , pp. 2244-2248
    • Hopkins Jr., H.P.1    Wu, C.-H.2    Hepler, L.G.3
  • 13
    • 38949107280 scopus 로고    scopus 로고
    • Determination of the content of salbutamol sulfate tablet with fluorospectrophotomertry
    • Huang, X.P., Huang, X.X., and Xie, S.X. 2005. Determination of the content of salbutamol sulfate tablet with fluorospectrophotomertry. Modern Preventive Medicine, 32 (5): 562-565.
    • (2005) Modern Preventive Medicine , vol.32 , Issue.5 , pp. 562-565
    • Huang, X.P.1    Huang, X.X.2    Xie, S.X.3
  • 14
    • 18544364476 scopus 로고    scopus 로고
    • Poly(p-aminobenzene sulfonic acid)-modified glassy carbon electrode for simultaneous detection of dopamine and ascorbic acid
    • Jin, G.Y., Zhang, Y.Z., and Cheng, W.X. 2005. Poly(p-aminobenzene sulfonic acid)-modified glassy carbon electrode for simultaneous detection of dopamine and ascorbic acid. Sensor Actuator B, 107: 528-534.
    • (2005) Sensor Actuator B , vol.107 , pp. 528-534
    • Jin, G.Y.1    Zhang, Y.Z.2    Cheng, W.X.3
  • 15
    • 38949092860 scopus 로고    scopus 로고
    • Content assessment method for salbutamol sulfate (SS) aerosol by UV detection
    • Keshu, C. 2001. Content assessment method for salbutamol sulfate (SS) aerosol by UV detection. Aerosol Communication, 6: 71-80.
    • (2001) Aerosol Communication , vol.6 , pp. 71-80
    • Keshu, C.1
  • 16
    • 0024982928 scopus 로고
    • Detection of catecholamines in brain tissue: Surface-modified electrodes enabling in vivo investigations of dopamine function
    • Lane, R.F. and Blaha, C.D. 1990. Detection of catecholamines in brain tissue: surface-modified electrodes enabling in vivo investigations of dopamine function. Langmuir, 6: 56-65.
    • (1990) Langmuir , vol.6 , pp. 56-65
    • Lane, R.F.1    Blaha, C.D.2
  • 17
    • 0346287259 scopus 로고
    • The transient response of electrodes coated with membrane-type polymer films under conditions of diffusion and migration of the redox-ions
    • Lang, R. and Doblhofer, K. 1987. The transient response of electrodes coated with membrane-type polymer films under conditions of diffusion and migration of the redox-ions. J. Electroanal. Chem., 216: 241.
    • (1987) J. Electroanal. Chem , vol.216 , pp. 241
    • Lang, R.1    Doblhofer, K.2
  • 18
    • 49249148639 scopus 로고
    • General expression of the linear potential sweep voltammogram in the case of diffusionless electrochemical systems
    • Laviron, E. 1979. General expression of the linear potential sweep voltammogram in the case of diffusionless electrochemical systems. J. Electroanal. Chem., 101: 10.
    • (1979) J. Electroanal. Chem , vol.101 , pp. 10
    • Laviron, E.1
  • 19
    • 33745015724 scopus 로고    scopus 로고
    • The determination of iodide based on a flow-injection coupling irreversible biamperometry
    • Li, L.J., Hao Cheng, H., Huang, W.Y., Kong, H.X., Wu, J.L., Lu, J.P., Gao, W., and Song, J.F. 2005. The determination of iodide based on a flow-injection coupling irreversible biamperometry. Chin. Chem. Lett., 16 (12): 1629-1632.
    • (2005) Chin. Chem. Lett , vol.16 , Issue.12 , pp. 1629-1632
    • Li, L.J.1    Hao Cheng, H.2    Huang, W.Y.3    Kong, H.X.4    Wu, J.L.5    Lu, J.P.6    Gao, W.7    Song, J.F.8
  • 20
    • 34248525070 scopus 로고    scopus 로고
    • Glucose biosensor based on immobilization of glucose oxidase in poly(o-aminophenol) film on polypyrrole-Pt nanocomposite modified glassy carbon electrode
    • Li, J. and Lin, X.Q. 2007. Glucose biosensor based on immobilization of glucose oxidase in poly(o-aminophenol) film on polypyrrole-Pt nanocomposite modified glassy carbon electrode. Biosensors & Bioelectronics, 22: 5656-5663.
    • (2007) Biosensors & Bioelectronics , vol.22 , pp. 5656-5663
    • Li, J.1    Lin, X.Q.2
  • 21
    • 2942568365 scopus 로고    scopus 로고
    • Covalent modification of a glassy carbon surface by electrochemical oxidation of r-aminobenzene sulfonic acid in aqueous solution
    • Li, X.F., Wan, Y., and Sun, C.Q. 2004. Covalent modification of a glassy carbon surface by electrochemical oxidation of r-aminobenzene sulfonic acid in aqueous solution. J. Electroanal. Chem., 569: 79-87.
    • (2004) J. Electroanal. Chem , vol.569 , pp. 79-87
    • Li, X.F.1    Wan, Y.2    Sun, C.Q.3
  • 22
    • 33947715128 scopus 로고    scopus 로고
    • DNA/Poly(p-aminobenzensulfonic acid) composite bi-layer modified glassy carbon electrode for determination of dopamine and uric acid under coexistence of ascorbic acid
    • Lin, X., Kang, G., and Lu, L. 2006. DNA/Poly(p-aminobenzensulfonic acid) composite bi-layer modified glassy carbon electrode for determination of dopamine and uric acid under coexistence of ascorbic acid. Bioelectrochemistry, 70: 235-244.
    • (2006) Bioelectrochemistry , vol.70 , pp. 235-244
    • Lin, X.1    Kang, G.2    Lu, L.3
  • 23
    • 2542449928 scopus 로고    scopus 로고
    • Electroanalysis of dopamine at a gold electrode modified with N-acetylcysteine self-assembled monolayer
    • Liu, T., Li, M.X., and Li, Q.Y. 2004. Electroanalysis of dopamine at a gold electrode modified with N-acetylcysteine self-assembled monolayer. Talanta, 63: 1053-1059.
    • (2004) Talanta , vol.63 , pp. 1053-1059
    • Liu, T.1    Li, M.X.2    Li, Q.Y.3
  • 24
    • 0035878892 scopus 로고    scopus 로고
    • 1H NMR study of the kinetics of substituted aniline polymerization. II. copolymerization of 2-methoxyaniline and 3-aminobenzenesulfonic acid
    • 1H NMR study of the kinetics of substituted aniline polymerization. II. copolymerization of 2-methoxyaniline and 3-aminobenzenesulfonic acid. J. Polym. Sci. A, Polym. Chem., 39: 2482-2493.
    • (2001) J. Polym. Sci. A, Polym. Chem , vol.39 , pp. 2482-2493
    • Mav, I.1    Zigon, M.2
  • 25
    • 0003036118 scopus 로고
    • Electron transport dynamics in partially quaternized poly(4-vinylpyridine) thin films containing ferri/ferrocyanide
    • Oh, S.M. and Faulkner, L.R. 1989. Electron transport dynamics in partially quaternized poly(4-vinylpyridine) thin films containing ferri/ferrocyanide. J. Electroanal. Chem., 269: 77.
    • (1989) J. Electroanal. Chem , vol.269 , pp. 77
    • Oh, S.M.1    Faulkner, L.R.2
  • 26
    • 38949131813 scopus 로고    scopus 로고
    • Peaslee amperometric detection of hydrazine by cyclic voltammetry and flow-injection analysis using ruthenium modified glassy carbon electrodes
    • Pinter, J.S., Brown, K.L., DeYoung, P.A., and Graham, F. 2006. Peaslee amperometric detection of hydrazine by cyclic voltammetry and flow-injection analysis using ruthenium modified glassy carbon electrodes. Talanta, 91: 1542-1553.
    • (2006) Talanta , vol.91 , pp. 1542-1553
    • Pinter, J.S.1    Brown, K.L.2    DeYoung, P.A.3    Graham, F.4
  • 27
    • 0032155396 scopus 로고    scopus 로고
    • High field conductivity in polypyrrole
    • Ribo, J.M., Anglada, M.C., and Hemandez, J.M. 1998. High field conductivity in polypyrrole. Synth. Met., 97: 229-238.
    • (1998) Synth. Met , vol.97 , pp. 229-238
    • Ribo, J.M.1    Anglada, M.C.2    Hemandez, J.M.3
  • 28
    • 0242625954 scopus 로고    scopus 로고
    • Flow-injection biamperometric direct determination of calcium dobesilate in irreversible couple system
    • Song, J.F. and Chen, J.Q. 2003. Flow-injection biamperometric direct determination of calcium dobesilate in irreversible couple system. J. Pharmaceut. Biomed. Anal., 33: 789-796.
    • (2003) J. Pharmaceut. Biomed. Anal , vol.33 , pp. 789-796
    • Song, J.F.1    Chen, J.Q.2
  • 29
    • 0002976564 scopus 로고    scopus 로고
    • Flow injection biamp erometric determination of ascorbic acid
    • Song, J.F., Zhao, C., Kang, X.F., and Guo, W. 2000. Flow injection biamp erometric determination of ascorbic acid. Chin. J. Anal., 28: 38-41.
    • (2000) Chin. J. Anal , vol.28 , pp. 38-41
    • Song, J.F.1    Zhao, C.2    Kang, X.F.3    Guo, W.4
  • 30
    • 0000419445 scopus 로고    scopus 로고
    • Determination of total phenols in environmental wastewater by flow-injection analysis with a biamperometric detector
    • Song, J.F., Zhao, C., Kang, X.F., and Guo, W. 2000. Determination of total phenols in environmental wastewater by flow-injection analysis with a biamperometric detector. Chem. J. Chinese Universities, 21: 535-537.
    • (2000) Chem. J. Chinese Universities , vol.21 , pp. 535-537
    • Song, J.F.1    Zhao, C.2    Kang, X.F.3    Guo, W.4
  • 31
    • 0037120990 scopus 로고    scopus 로고
    • Theoretical and experimental study of the biamperometry for irreversible redox couple in flow system
    • Song, J., Zhao, C., Guo, W., Kang, X., and Zhang, J. 2002. Theoretical and experimental study of the biamperometry for irreversible redox couple in flow system. Anal. Chim. Acta, 470: 229-240.
    • (2002) Anal. Chim. Acta , vol.470 , pp. 229-240
    • Song, J.1    Zhao, C.2    Guo, W.3    Kang, X.4    Zhang, J.5
  • 32
    • 0035275846 scopus 로고    scopus 로고
    • Electropolymerized poly(2-vinylpyridine) coatings as ion-exchange polymer modified electrodes
    • Tantavichet, N., Pritzker, M.D., and Burns, C.M. 2001. Electropolymerized poly(2-vinylpyridine) coatings as ion-exchange polymer modified electrodes. J. App. Electrochem., 31: 281-291.
    • (2001) J. App. Electrochem , vol.31 , pp. 281-291
    • Tantavichet, N.1    Pritzker, M.D.2    Burns, C.M.3
  • 33
    • 38949161854 scopus 로고    scopus 로고
    • The Pharmacopoeia Committee of the Ministry of Health of PR China, Pharmacopoeia of PR China Part II. 2000. Chemical Industry Press: Beijing.
    • The Pharmacopoeia Committee of the Ministry of Health of PR China, Pharmacopoeia of PR China Part II. 2000. Chemical Industry Press: Beijing.
  • 34
    • 0000141802 scopus 로고
    • Electrochemical polymerization of aromatic amines: IR, XPS, and PMT study of thin film formation on a Pt electrode
    • Volkov, A., Tourillon, G., Lacaze, P.C., and Dubois, J.E. 1980. Electrochemical polymerization of aromatic amines: IR, XPS, and PMT study of thin film formation on a Pt electrode. J. Electroanal. Chem., 115: 279-291.
    • (1980) J. Electroanal. Chem , vol.115 , pp. 279-291
    • Volkov, A.1    Tourillon, G.2    Lacaze, P.C.3    Dubois, J.E.4
  • 35
    • 38949200932 scopus 로고    scopus 로고
    • Study on pharmacokinetics and relative bioavailability of a sustained release preparation of albuterol
    • Wang, J.X., Chen, D.G., Cai, C.Z., Li, T.L., and Qin, Y.P. 2000. Study on pharmacokinetics and relative bioavailability of a sustained release preparation of albuterol. J. Chin. Pharmaceut. Sci., 9 (1): 31-38.
    • (2000) J. Chin. Pharmaceut. Sci , vol.9 , Issue.1 , pp. 31-38
    • Wang, J.X.1    Chen, D.G.2    Cai, C.Z.3    Li, T.L.4    Qin, Y.P.5
  • 36
    • 8844245674 scopus 로고    scopus 로고
    • A selective voltammetric method for uric acid detection at a glassy carbon electrode modified with electrodeposited film containing DNA and Pt-Fe(III) nanocomposites
    • Wang, S.Q., Lu, L.P., and Lin, X.Q. 2004. A selective voltammetric method for uric acid detection at a glassy carbon electrode modified with electrodeposited film containing DNA and Pt-Fe(III) nanocomposites. Electroanalysis, 16: 1734-1738.
    • (2004) Electroanalysis , vol.16 , pp. 1734-1738
    • Wang, S.Q.1    Lu, L.P.2    Lin, X.Q.3
  • 37
    • 0035975059 scopus 로고    scopus 로고
    • Sensitive determination of dopamine on poly(aminobenzoic acid)-modified electrode and the application toward an experimental Parkinsonian animal model
    • Xu, F., Gao, M.N., Wang, L., Shi, G.Y., Zhang, W., Jin, L.T., and Jin, J. 2001. Sensitive determination of dopamine on poly(aminobenzoic acid)-modified electrode and the application toward an experimental Parkinsonian animal model. Talanta, 55: 329-336.
    • (2001) Talanta , vol.55 , pp. 329-336
    • Xu, F.1    Gao, M.N.2    Wang, L.3    Shi, G.Y.4    Zhang, W.5    Jin, L.T.6    Jin, J.7
  • 38
    • 38949097423 scopus 로고    scopus 로고
    • The application and technology research of plasma cleaning
    • Zhang, C. 2006. The application and technology research of plasma cleaning. Application for Electronic Products Manufacturing, 137: 23-28.
    • (2006) Application for Electronic Products Manufacturing , vol.137 , pp. 23-28
    • Zhang, C.1
  • 40
    • 0036387817 scopus 로고    scopus 로고
    • Determination of total phenols in environmental wastewater by flow-injection analysis with a biamperometric detector
    • Zhao, C., Song, J., and Zhang, J. 2002. Determination of total phenols in environmental wastewater by flow-injection analysis with a biamperometric detector. Anal. Bioanal. Chem., 374: 498-504.
    • (2002) Anal. Bioanal. Chem , vol.374 , pp. 498-504
    • Zhao, C.1    Song, J.2    Zhang, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.