메뉴 건너뛰기




Volumn 23, Issue 2, 2008, Pages 164-169

Kinematic Comparison Between Mobile-Bearing and Fixed-Bearing Inserts in NexGen Legacy Posterior Stabilized Flex Total Knee Arthroplasty

Author keywords

femoral rollback; kinematics; mobile bearing; tibial rotation; total knee arthroplasty

Indexed keywords

ADULT; AGED; ARTICLE; CLINICAL ARTICLE; CONTROLLED STUDY; FEMALE; FLEXOR REFLEX; FLUOROSCOPY; HUMAN; KINEMATICS; MALE; MATERIALS; POSTOPERATIVE CARE; RADIOGRAPHY; RANGE OF MOTION; SURGICAL TECHNIQUE; TOTAL KNEE REPLACEMENT;

EID: 38949113207     PISSN: 08835403     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.arth.2007.01.009     Document Type: Article
Times cited : (23)

References (9)
  • 1
    • 0033660048 scopus 로고    scopus 로고
    • Tibiofemoral movement 3: full flexion in the living knee studied by MRI
    • Nakagawa S., Kadoya Y., Todo S., et al. Tibiofemoral movement 3: full flexion in the living knee studied by MRI. J Bone Joint Surg Br 82 (2000) 1199
    • (2000) J Bone Joint Surg Br , vol.82 , pp. 1199
    • Nakagawa, S.1    Kadoya, Y.2    Todo, S.3
  • 2
    • 0032935960 scopus 로고    scopus 로고
    • Anteroposterior and rotational movement of femur during knee flexion
    • Todo S., Kadoya Y., Moilanen T., et al. Anteroposterior and rotational movement of femur during knee flexion. Clin Orthop 362 (1999) 162
    • (1999) Clin Orthop , vol.362 , pp. 162
    • Todo, S.1    Kadoya, Y.2    Moilanen, T.3
  • 3
    • 0036713185 scopus 로고    scopus 로고
    • The effects of early rollback in total knee arthroplasty on stair stepping
    • Draganich L.F., Piotrowski G.A., Martell J., et al. The effects of early rollback in total knee arthroplasty on stair stepping. J Arthroplasty 17 (2002) 723
    • (2002) J Arthroplasty , vol.17 , pp. 723
    • Draganich, L.F.1    Piotrowski, G.A.2    Martell, J.3
  • 4
    • 38949161561 scopus 로고    scopus 로고
    • NexGen Complete Knee Solution Legacy Knee Posterior Stabilized (LPS) LPS-Flex Fixed Bearing Knee: http://www.zimmer.com/z/ctl/op/global/action/1/id/44/template/MP/prcat/M 3/prod/y (accessed 18/11/05).
    • NexGen Complete Knee Solution Legacy Knee Posterior Stabilized (LPS) LPS-Flex Fixed Bearing Knee: http://www.zimmer.com/z/ctl/op/global/action/1/id/44/template/MP/prcat/M 3/prod/y (accessed 18/11/05).
  • 5
    • 38949111090 scopus 로고    scopus 로고
    • A new method to measure tibial rotational angle during knee flexion
    • Yamamoto T., Takayanagi F., Kondo K., et al. A new method to measure tibial rotational angle during knee flexion. J Aichi Med Univ Assoc 27 (1999) 295
    • (1999) J Aichi Med Univ Assoc , vol.27 , pp. 295
    • Yamamoto, T.1    Takayanagi, F.2    Kondo, K.3
  • 6
    • 0242441676 scopus 로고    scopus 로고
    • The kinematics of fixed- and mobile-bearing total knee arthroplasty
    • Most E., Li G., Schul S., et al. The kinematics of fixed- and mobile-bearing total knee arthroplasty. Clin Orthop 416 (2003) 197
    • (2003) Clin Orthop , vol.416 , pp. 197
    • Most, E.1    Li, G.2    Schul, S.3
  • 7
    • 0038405166 scopus 로고    scopus 로고
    • In vivo fluoroscopic analysis of fixed-bearing total knee replacements
    • Dennis D.A., Komistek R.D., and Mahfouz M.R. In vivo fluoroscopic analysis of fixed-bearing total knee replacements. Clin Orthop 410 (2003) 114
    • (2003) Clin Orthop , vol.410 , pp. 114
    • Dennis, D.A.1    Komistek, R.D.2    Mahfouz, M.R.3
  • 8
    • 0242664747 scopus 로고    scopus 로고
    • Impact of patellofemoral design on patellofemoral forces and polyethylene stresses
    • D'Lima D.D., Chen P.C., Kester M.A., et al. Impact of patellofemoral design on patellofemoral forces and polyethylene stresses. J Bone Joint Surg Am 85-93 (2003) 85
    • (2003) J Bone Joint Surg Am , vol.85 , pp. 85-93
    • D'Lima, D.D.1    Chen, P.C.2    Kester, M.A.3
  • 9
    • 0036849841 scopus 로고    scopus 로고
    • The causes of insert backside wear in total knee arthroplasty
    • Wasielewski R.C. The causes of insert backside wear in total knee arthroplasty. Clin Orthop 404 (2002) 232
    • (2002) Clin Orthop , vol.404 , pp. 232
    • Wasielewski, R.C.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.