메뉴 건너뛰기




Volumn 23, Issue 2, 2008, Pages 299-303

Dislocation of Rotating-Hinge Knee Prostheses with Antidislocation Mechanism

Author keywords

complications; dislocation; rotating hinge; total knee arthroplasty

Indexed keywords

POLYETHYLENE;

EID: 38949085541     PISSN: 08835403     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.arth.2006.11.020     Document Type: Article
Times cited : (17)

References (7)
  • 2
    • 0022540894 scopus 로고
    • Evaluation of the Noiles hinged knee prosthesis. A five-year study of seventeen knees
    • Shindell R., Neumann R., Connolly J.F., et al. Evaluation of the Noiles hinged knee prosthesis. A five-year study of seventeen knees. J Bone Joint Surg Am 68 (1986) 579
    • (1986) J Bone Joint Surg Am , vol.68 , pp. 579
    • Shindell, R.1    Neumann, R.2    Connolly, J.F.3
  • 3
    • 0020472481 scopus 로고
    • The kinematic rotating hinge: biomechanics and clinical application
    • Walker P.S., Emerson R., Potter T., et al. The kinematic rotating hinge: biomechanics and clinical application. Orthop Clin North Am 13 (1982) 187
    • (1982) Orthop Clin North Am , vol.13 , pp. 187
    • Walker, P.S.1    Emerson, R.2    Potter, T.3
  • 4
    • 0037362591 scopus 로고    scopus 로고
    • Dislocation of rotating hinge total knee prostheses. A biomechanical analysis
    • Ward W.G., Haight D., Ritchie P., et al. Dislocation of rotating hinge total knee prostheses. A biomechanical analysis. J Bone Joint Surg Am 85 (2003) 448
    • (2003) J Bone Joint Surg Am , vol.85 , pp. 448
    • Ward, W.G.1    Haight, D.2    Ritchie, P.3
  • 5
    • 0031840093 scopus 로고    scopus 로고
    • Problems with the rotaflex. A 10-year review of a rotating hinge prosthesis
    • David H.G., Bishay M., and James E.T.R. Problems with the rotaflex. A 10-year review of a rotating hinge prosthesis. J Arthroplasty 13 (1998) 402
    • (1998) J Arthroplasty , vol.13 , pp. 402
    • David, H.G.1    Bishay, M.2    James, E.T.R.3
  • 6
    • 0034113422 scopus 로고    scopus 로고
    • Early catastrophic failure of rotating hinge total knee prosthesis
    • Wang C.J., and Wang H.E. Early catastrophic failure of rotating hinge total knee prosthesis. J Arthroplasty 15 (2000) 387
    • (2000) J Arthroplasty , vol.15 , pp. 387
    • Wang, C.J.1    Wang, H.E.2
  • 7
    • 18144426108 scopus 로고    scopus 로고
    • Dislocation of rotating hinge knee prostheses. A report of four cases
    • Ward W.G., Haight D., Ritchie P., et al. Dislocation of rotating hinge knee prostheses. A report of four cases. J Bone Joint Surg Am 87 (2005) 1108
    • (2005) J Bone Joint Surg Am , vol.87 , pp. 1108
    • Ward, W.G.1    Haight, D.2    Ritchie, P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.