메뉴 건너뛰기




Volumn 129, Issue 2, 2008, Pages 896-902

Development of a method for total plasma thiols measurement using a disposable screen-printed carbon electrode coupled with a MnO2 reactor

Author keywords

Disposable; Plasma; Screen printed electrode; Thiols

Indexed keywords

CARBON; ELECTROCHEMISTRY; MANGANESE COMPOUNDS; ORGANIC ACIDS; PLASMA (HUMAN); SILVER COMPOUNDS;

EID: 38949084883     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.snb.2007.10.004     Document Type: Article
Times cited : (12)

References (33)
  • 1
    • 0034662162 scopus 로고    scopus 로고
    • Case-control study of plasma folate, homocysteine, vitamin B12, and cysteine as markers of cervical dysplasia
    • Goodman M.T., McDuffie K., Hernandez B., Wilkens L.R., and Selhub J. Case-control study of plasma folate, homocysteine, vitamin B12, and cysteine as markers of cervical dysplasia. Cancer 89 (2000) 376-382
    • (2000) Cancer , vol.89 , pp. 376-382
    • Goodman, M.T.1    McDuffie, K.2    Hernandez, B.3    Wilkens, L.R.4    Selhub, J.5
  • 3
    • 0034011876 scopus 로고    scopus 로고
    • Status of glutathione and other thiols and disulfides in human plasma
    • Kleinman W.A., and Richie J.P. Status of glutathione and other thiols and disulfides in human plasma. Biochem. Pharmacol. 60 (2000) 19-29
    • (2000) Biochem. Pharmacol. , vol.60 , pp. 19-29
    • Kleinman, W.A.1    Richie, J.P.2
  • 4
    • 0032800599 scopus 로고    scopus 로고
    • Automated high-performance liquid chromatographic method for the determination of homocysteine in plasma samples
    • Carducci C., Birarelli M., Nola M., and Antonozzi I. Automated high-performance liquid chromatographic method for the determination of homocysteine in plasma samples. J. Chromatogr. A 846 (1999) 93-100
    • (1999) J. Chromatogr. A , vol.846 , pp. 93-100
    • Carducci, C.1    Birarelli, M.2    Nola, M.3    Antonozzi, I.4
  • 5
    • 0032489398 scopus 로고    scopus 로고
    • Urinary excretion measurement of cysteine and homocysteine in the form of their S-pyridinium derivatives by high-performance liquid chromatography with ultraviolet detection
    • Kaniowska E., Chwatko G., Glowacki R., Kubalczyk P., and Bald E. Urinary excretion measurement of cysteine and homocysteine in the form of their S-pyridinium derivatives by high-performance liquid chromatography with ultraviolet detection. J. Chromatogr. A 798 (1998) 27-35
    • (1998) J. Chromatogr. A , vol.798 , pp. 27-35
    • Kaniowska, E.1    Chwatko, G.2    Glowacki, R.3    Kubalczyk, P.4    Bald, E.5
  • 6
    • 0032988952 scopus 로고    scopus 로고
    • Gas chromatographic-mass spectrometric determination of total homocysteine in human plasma by stable isotope dilution: method and clinical applications
    • Ducros V., Schmitt D., Pernod G., Faure H., Polack B., and Favier A. Gas chromatographic-mass spectrometric determination of total homocysteine in human plasma by stable isotope dilution: method and clinical applications. J. Chromatogr. B 729 (1999) 333-339
    • (1999) J. Chromatogr. B , vol.729 , pp. 333-339
    • Ducros, V.1    Schmitt, D.2    Pernod, G.3    Faure, H.4    Polack, B.5    Favier, A.6
  • 7
    • 0030944645 scopus 로고    scopus 로고
    • Determination of homocysteine and other thiols in human plasma by capillary electrophoresis
    • Kang S.H., Kim J.-W., and Chung D.S. Determination of homocysteine and other thiols in human plasma by capillary electrophoresis. J. Pharm. Biomed. Anal. 15 (1997) 1435-1441
    • (1997) J. Pharm. Biomed. Anal. , vol.15 , pp. 1435-1441
    • Kang, S.H.1    Kim, J.-W.2    Chung, D.S.3
  • 8
    • 0032730140 scopus 로고    scopus 로고
    • Determination of reduced and oxidized homocysteine and related thiols in plasma by thiol-specific pre-column derivatization and capillary electrophoresis with laser-induced fluorescence detection
    • Chassaing C., Gonin J., Wilcox C.S., and Wainer I.W. Determination of reduced and oxidized homocysteine and related thiols in plasma by thiol-specific pre-column derivatization and capillary electrophoresis with laser-induced fluorescence detection. J. Chromatogr. B 735 (1999) 219-227
    • (1999) J. Chromatogr. B , vol.735 , pp. 219-227
    • Chassaing, C.1    Gonin, J.2    Wilcox, C.S.3    Wainer, I.W.4
  • 9
    • 0022028543 scopus 로고
    • Detection of thiols and disulfides in liver samples using liquid chromatography/electrochemistry
    • Lunte S.M., and Kissinger P.T. Detection of thiols and disulfides in liver samples using liquid chromatography/electrochemistry. J. Liq. Chromatogr. 8 (1985) 691-706
    • (1985) J. Liq. Chromatogr. , vol.8 , pp. 691-706
    • Lunte, S.M.1    Kissinger, P.T.2
  • 10
    • 0024394757 scopus 로고
    • Determination of homocysteine, penicillamine, and their symmetrical and mixed disulfides by liquid chromatography with electrochemical detection
    • Rabenstein D.L., and Yamashita G.T. Determination of homocysteine, penicillamine, and their symmetrical and mixed disulfides by liquid chromatography with electrochemical detection. Anal. Biochem. 180 (1989) 259-263
    • (1989) Anal. Biochem. , vol.180 , pp. 259-263
    • Rabenstein, D.L.1    Yamashita, G.T.2
  • 11
    • 0032796721 scopus 로고    scopus 로고
    • A new HPLC method for the simultaneous determination of oxidized and reduced plasma aminothiols using coulometric electrochemical detection
    • Melnyk S., Pogribna M., Pogribny I., Hine R.J., and James S.J. A new HPLC method for the simultaneous determination of oxidized and reduced plasma aminothiols using coulometric electrochemical detection. J. Nutr. Biochem. 10 (1999) 490-497
    • (1999) J. Nutr. Biochem. , vol.10 , pp. 490-497
    • Melnyk, S.1    Pogribna, M.2    Pogribny, I.3    Hine, R.J.4    James, S.J.5
  • 12
    • 0032509290 scopus 로고    scopus 로고
    • Total homocysteine levels in plasma: high-performance liquid chromatographic determination with electrochemical detection and glassy carbon electrode
    • D'Eramo J.L., Finkelstein A.E., Boccazzi F.O., and Fridman O. Total homocysteine levels in plasma: high-performance liquid chromatographic determination with electrochemical detection and glassy carbon electrode. J. Chromatogr. B 720 (1998) 205-210
    • (1998) J. Chromatogr. B , vol.720 , pp. 205-210
    • D'Eramo, J.L.1    Finkelstein, A.E.2    Boccazzi, F.O.3    Fridman, O.4
  • 13
    • 0036125451 scopus 로고    scopus 로고
    • Application of micellar electrokinetic chromatography to the quality control of a pharmaceutical preparation containing three bronchodilators
    • Pasas S.A., Lacher N.A., Davies M.I., and Lunte S.M. Application of micellar electrokinetic chromatography to the quality control of a pharmaceutical preparation containing three bronchodilators. Electrophoresis 23 (2002) 579-583
    • (2002) Electrophoresis , vol.23 , pp. 579-583
    • Pasas, S.A.1    Lacher, N.A.2    Davies, M.I.3    Lunte, S.M.4
  • 14
    • 0031606924 scopus 로고    scopus 로고
    • Simplified simultaneous assay of total plasma homocysteine and methionine by HPLC and pulsed integrated amperometry
    • Cole D.E.C., Lehotay D.C., and Evrovski J. Simplified simultaneous assay of total plasma homocysteine and methionine by HPLC and pulsed integrated amperometry. Clin. Chem. 44 (1998) 188-190
    • (1998) Clin. Chem. , vol.44 , pp. 188-190
    • Cole, D.E.C.1    Lehotay, D.C.2    Evrovski, J.3
  • 15
    • 0035021823 scopus 로고    scopus 로고
    • Simultaneous determination of total plasma glutathione, homocysteine, cysteinylglycine, and methionine by high-performance liquid chromatography with electrochemical detection
    • Houze P., Gamra S., Madelaine I., Bousquet B., and Gourmel B. Simultaneous determination of total plasma glutathione, homocysteine, cysteinylglycine, and methionine by high-performance liquid chromatography with electrochemical detection. J. Clin. Lab. Anal. 15 (2001) 144-153
    • (2001) J. Clin. Lab. Anal. , vol.15 , pp. 144-153
    • Houze, P.1    Gamra, S.2    Madelaine, I.3    Bousquet, B.4    Gourmel, B.5
  • 18
    • 0026023155 scopus 로고
    • Voltammetric behaviour of screen-printed carbon electrodes, chemically modified with selected mediators, and their application as sensors for the determination of reduced glutathione
    • Wring S.A., Hart J.P., and Birch B.J. Voltammetric behaviour of screen-printed carbon electrodes, chemically modified with selected mediators, and their application as sensors for the determination of reduced glutathione. Analyst 116 (1991) 123-130
    • (1991) Analyst , vol.116 , pp. 123-130
    • Wring, S.A.1    Hart, J.P.2    Birch, B.J.3
  • 19
    • 5144219513 scopus 로고
    • Determination of sulfur species by cathodic square wave stripping voltammetry; compounds relevant to natural sulfur mineralization
    • Von Wandruska R., Yuan X., and Morra M.J. Determination of sulfur species by cathodic square wave stripping voltammetry; compounds relevant to natural sulfur mineralization. Talanta 40 (1993) 37-42
    • (1993) Talanta , vol.40 , pp. 37-42
    • Von Wandruska, R.1    Yuan, X.2    Morra, M.J.3
  • 20
    • 0028014385 scopus 로고
    • Application of catalytic stripping voltammetry for the determination of organic sulfur compounds at a hanging mercury drop electrode: behaviour of cysteine, cystine and N-acetylcysteine in the presence of nickel ion
    • Banica F.G., Moreira J.C., and Fogg A.G. Application of catalytic stripping voltammetry for the determination of organic sulfur compounds at a hanging mercury drop electrode: behaviour of cysteine, cystine and N-acetylcysteine in the presence of nickel ion. Analyst 119 (1994) 309-318
    • (1994) Analyst , vol.119 , pp. 309-318
    • Banica, F.G.1    Moreira, J.C.2    Fogg, A.G.3
  • 21
    • 0008357662 scopus 로고
    • Bioelectrocatalysis at organic conducting salt electrodes. Use of hexamethylenetetratellurafulvalene tetracyanoquinodimethane (HMTTeF-TCNQ) as a versatile electrode material
    • Zhao S., and Lennox R.B. Bioelectrocatalysis at organic conducting salt electrodes. Use of hexamethylenetetratellurafulvalene tetracyanoquinodimethane (HMTTeF-TCNQ) as a versatile electrode material. J. Electroanal. Chem. 346 (1993) 161-173
    • (1993) J. Electroanal. Chem. , vol.346 , pp. 161-173
    • Zhao, S.1    Lennox, R.B.2
  • 22
    • 0025822887 scopus 로고
    • Determination of glutathione at enzyme-modified and unmodified glassy carbon electrodes
    • Hua C., Smith M.R., and O'Fagain C. Determination of glutathione at enzyme-modified and unmodified glassy carbon electrodes. Analyst 116 (1991) 929-932
    • (1991) Analyst , vol.116 , pp. 929-932
    • Hua, C.1    Smith, M.R.2    O'Fagain, C.3
  • 23
    • 0032155288 scopus 로고    scopus 로고
    • 2-film electrodes applied for anodic detection of selected sulfur compounds
    • 2-film electrodes applied for anodic detection of selected sulfur compounds. J. Electroanal. Chem. 455 (1998) 153-160
    • (1998) J. Electroanal. Chem. , vol.455 , pp. 153-160
    • Popovic, N.D.1    Cox, J.A.2    Johnson, D.C.3
  • 24
    • 0037086254 scopus 로고    scopus 로고
    • Determination of thiols by capillary electrophoresis with amperometric detection at a coenzyme pyrroloquinoline quinone modified electrode
    • Inoue T., and Kirchhoff J.R. Determination of thiols by capillary electrophoresis with amperometric detection at a coenzyme pyrroloquinoline quinone modified electrode. Anal. Chem. 74 (2002) 1349-1354
    • (2002) Anal. Chem. , vol.74 , pp. 1349-1354
    • Inoue, T.1    Kirchhoff, J.R.2
  • 25
    • 0035951517 scopus 로고    scopus 로고
    • Electrochemical detection of thiols in biological media
    • Lawrence N.S., Davis J., and Compton R.G. Electrochemical detection of thiols in biological media. Talanta 53 (2001) 1089-1094
    • (2001) Talanta , vol.53 , pp. 1089-1094
    • Lawrence, N.S.1    Davis, J.2    Compton, R.G.3
  • 26
    • 0036170080 scopus 로고    scopus 로고
    • Native polyacrylamide gel electrophoresis of membrane proteins: glutaminase detection after in situ specific activity staining
    • White P.C., Lawrence N.S., Davis J., and Compton R.G. Native polyacrylamide gel electrophoresis of membrane proteins: glutaminase detection after in situ specific activity staining. Electroanalysis 14 (2002) 89-98
    • (2002) Electroanalysis , vol.14 , pp. 89-98
    • White, P.C.1    Lawrence, N.S.2    Davis, J.3    Compton, R.G.4
  • 27
    • 0042427270 scopus 로고    scopus 로고
    • Analytical determination of homocysteine: a review
    • Nebrassova O., Lawrence N.S., and Compton R.G. Analytical determination of homocysteine: a review. Talanta 60 (2003) 1085-1095
    • (2003) Talanta , vol.60 , pp. 1085-1095
    • Nebrassova, O.1    Lawrence, N.S.2    Compton, R.G.3
  • 29
    • 0035955801 scopus 로고    scopus 로고
    • Electrochemically initiated 1,4 additions: a versatile route to the determination of thiols
    • White P.C., Lawrence N.S., Davis J., and Compton R.G. Electrochemically initiated 1,4 additions: a versatile route to the determination of thiols. Anal. Chim. Acta 447 (2001) 1-10
    • (2001) Anal. Chim. Acta , vol.447 , pp. 1-10
    • White, P.C.1    Lawrence, N.S.2    Davis, J.3    Compton, R.G.4
  • 30
    • 30744443264 scopus 로고    scopus 로고
    • An electrochemical cell coupled with disposable screen-printed electrodes for use in flow injection analysis
    • Hsu C.-T., Chung H.-H., Lyuu H.-J., Tsai D.-M., Kumar A.S., and Zen J.-M. An electrochemical cell coupled with disposable screen-printed electrodes for use in flow injection analysis. Anal. Sci. 22 (2006) 35-38
    • (2006) Anal. Sci. , vol.22 , pp. 35-38
    • Hsu, C.-T.1    Chung, H.-H.2    Lyuu, H.-J.3    Tsai, D.-M.4    Kumar, A.S.5    Zen, J.-M.6
  • 31
    • 0033371178 scopus 로고    scopus 로고
    • Abnormal markers of endothelial cell activation and oxidative stress in children, adolescents and young adults with Type 1 diabetes with no clinical vascular disease
    • Elhadd Tarik A., Kennedy G., Hill A., McLaren M., Newton R.W., Greene S.A., and Belch J.J.F. Abnormal markers of endothelial cell activation and oxidative stress in children, adolescents and young adults with Type 1 diabetes with no clinical vascular disease. Diabetes Metab. Res. Rev. 15 (1999) 405-411
    • (1999) Diabetes Metab. Res. Rev. , vol.15 , pp. 405-411
    • Elhadd Tarik, A.1    Kennedy, G.2    Hill, A.3    McLaren, M.4    Newton, R.W.5    Greene, S.A.6    Belch, J.J.F.7
  • 32
    • 0033522883 scopus 로고    scopus 로고
    • Determination of glutathione in vivo by microdialysis using liquid chromatography with a cobalt hexacyanoferrate chemically modified electrode
    • Shi G.Y., Lu J.X., Xu F., Sun W.L., Lin L.T., Yamamoto K., Tao S.G., and Jin J.Y. Determination of glutathione in vivo by microdialysis using liquid chromatography with a cobalt hexacyanoferrate chemically modified electrode. Anal. Chim. Acta 391 (1999) 307-313
    • (1999) Anal. Chim. Acta , vol.391 , pp. 307-313
    • Shi, G.Y.1    Lu, J.X.2    Xu, F.3    Sun, W.L.4    Lin, L.T.5    Yamamoto, K.6    Tao, S.G.7    Jin, J.Y.8
  • 33
    • 0033886940 scopus 로고    scopus 로고
    • Electrocatalytic and analytical responses of 10-methylphenothiazine toward reduced glutathione
    • Gong X., and Li H.L. Electrocatalytic and analytical responses of 10-methylphenothiazine toward reduced glutathione. J. Electrochem. Soc. 147 (2000) 238-241
    • (2000) J. Electrochem. Soc. , vol.147 , pp. 238-241
    • Gong, X.1    Li, H.L.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.