메뉴 건너뛰기




Volumn 190, Issue 2, 2008, Pages 459-465

Diagnostic accuracy and reading time to detect intracranial aneurysms on MR angiography using a computer-aided diagnosis system

Author keywords

Computer aided diagnosis; Intracranial aneurysms; MR angiography; Observer performance; Reading time; Receiver operating characteristic

Indexed keywords

ADULT; AREA UNDER THE CURVE; ARTICLE; CLINICAL ARTICLE; COMPUTER ASSISTED RADIOGRAPHY; CONTROLLED STUDY; DIAGNOSTIC ACCURACY; DIAGNOSTIC IMAGING; FEMALE; HUMAN; IMAGE ANALYSIS; INTRACRANIAL ANEURYSM; MAGNETIC RESONANCE ANGIOGRAPHY; MALE; NEURORADIOLOGY; OUTCOME ASSESSMENT; PRIORITY JOURNAL; RADIOLOGIST; RECEIVER OPERATING CHARACTERISTIC;

EID: 38849194784     PISSN: 0361803X     EISSN: None     Source Type: Journal    
DOI: 10.2214/AJR.07.2642     Document Type: Article
Times cited : (20)

References (22)
  • 1
    • 0029157124 scopus 로고
    • Elective surgery for asymptomatic, unruptured, intracranial aneurysms: A cost-effectiveness analysis
    • King JT, Glick HA, Mason TJ, Flamm ES. Elective surgery for asymptomatic, unruptured, intracranial aneurysms: a cost-effectiveness analysis. J Neurosurg 1995; 83:403-412
    • (1995) J Neurosurg , vol.83 , pp. 403-412
    • King, J.T.1    Glick, H.A.2    Mason, T.J.3    Flamm, E.S.4
  • 2
    • 0028032096 scopus 로고
    • The incidence and treatment of asymptomatic, unruptured cerebral aneurysms
    • Nakagawa T, Hashi K. The incidence and treatment of asymptomatic, unruptured cerebral aneurysms. J Neurosurg 1994; 80:217-223
    • (1994) J Neurosurg , vol.80 , pp. 217-223
    • Nakagawa, T.1    Hashi, K.2
  • 3
    • 0033939529 scopus 로고    scopus 로고
    • Cost-effectiveness of screening unruptured cerebral aneurysms in Japan
    • Baba Y, Takahashi M, Korogi Y. Cost-effectiveness of screening unruptured cerebral aneurysms in Japan. Eur Radiol 2000; 10[suppl 3]:S362-S365
    • (2000) Eur Radiol , vol.10 , Issue.SUPPL. 3
    • Baba, Y.1    Takahashi, M.2    Korogi, Y.3
  • 4
    • 0028148172 scopus 로고
    • Blinded prospective evaluation of sensitivity of MR angiography to known intracranial aneurysms: Importance of aneurysm size
    • Huston J 3rd, Nichols DA, Luetmer PH, et al. Blinded prospective evaluation of sensitivity of MR angiography to known intracranial aneurysms: importance of aneurysm size. Am J Neuroradiol 1994; 15:1607-1614
    • (1994) Am J Neuroradiol , vol.15 , pp. 1607-1614
    • Huston 3rd, J.1    Nichols, D.A.2    Luetmer, P.H.3
  • 5
    • 7044233293 scopus 로고    scopus 로고
    • Overview on research and development of computer-aided diagnostic schemes
    • Doi K. Overview on research and development of computer-aided diagnostic schemes. Semin Ultrasound CT MR 2004; 25:404-410
    • (2004) Semin Ultrasound CT MR , vol.25 , pp. 404-410
    • Doi, K.1
  • 6
    • 21644447318 scopus 로고    scopus 로고
    • Doi K. Current status and future potential of computer-aided diagnosis in medical imaging. Br J Radiol 2005; 78[spec no 1]:3-19
    • Doi K. Current status and future potential of computer-aided diagnosis in medical imaging. Br J Radiol 2005; 78[spec no 1]:3-19
  • 7
    • 0034860859 scopus 로고    scopus 로고
    • Screening mammography with computer-aided detection: Prospective study of 12,860 patients in a community breast center
    • Freer TW, Ulissey MJ. Screening mammography with computer-aided detection: prospective study of 12,860 patients in a community breast center. Radiology 2001; 220:781-786
    • (2001) Radiology , vol.220 , pp. 781-786
    • Freer, T.W.1    Ulissey, M.J.2
  • 8
    • 3242748896 scopus 로고    scopus 로고
    • Can computer-aided detection with double reading of screening mammograms help decrease the false-negative rate? Initial experience
    • Destounis SV, DiNitto P, Logan-Young W, Bonaccio E, Zuley ML, Willison KM. Can computer-aided detection with double reading of screening mammograms help decrease the false-negative rate? Initial experience. Radiology 2004; 232:578-584
    • (2004) Radiology , vol.232 , pp. 578-584
    • Destounis, S.V.1    DiNitto, P.2    Logan-Young, W.3    Bonaccio, E.4    Zuley, M.L.5    Willison, K.M.6
  • 9
    • 0029992390 scopus 로고    scopus 로고
    • Effect of a computer-aided diagnosis scheme on radiologists' performance in detection of lung nodules on radiographs
    • Kobayashi T, Xu XW, MacMahon H, Metz CE, Doi K. Effect of a computer-aided diagnosis scheme on radiologists' performance in detection of lung nodules on radiographs. Radiology 1996; 199:843-848
    • (1996) Radiology , vol.199 , pp. 843-848
    • Kobayashi, T.1    Xu, X.W.2    MacMahon, H.3    Metz, C.E.4    Doi, K.5
  • 10
    • 9144248947 scopus 로고    scopus 로고
    • Improved detection of lung nodules on chest radiographs using a commercial computer-aided diagnosis system
    • Kakeda S, Moriya J, Sato H, et al. Improved detection of lung nodules on chest radiographs using a commercial computer-aided diagnosis system. AJR 2004; 182:505-510
    • (2004) AJR , vol.182 , pp. 505-510
    • Kakeda, S.1    Moriya, J.2    Sato, H.3
  • 11
    • 33750293407 scopus 로고    scopus 로고
    • Effect of temporal subtraction technique on interpretation time and diagnostic accuracy of chest radiography
    • Kakeda S, Kamada K, Hatakeyama Y, et al. Effect of temporal subtraction technique on interpretation time and diagnostic accuracy of chest radiography. AJR 2006; 187:1253-1259
    • (2006) AJR , vol.187 , pp. 1253-1259
    • Kakeda, S.1    Kamada, K.2    Hatakeyama, Y.3
  • 12
    • 7644222043 scopus 로고    scopus 로고
    • Automated computerized scheme for detection of unruptured intracranial aneurysms in three-dimensional MRA
    • Arimura H, Li Q, Korogi Y, et al. Automated computerized scheme for detection of unruptured intracranial aneurysms in three-dimensional MRA. Acad Radiol 2004; 11:1093-1104
    • (2004) Acad Radiol , vol.11 , pp. 1093-1104
    • Arimura, H.1    Li, Q.2    Korogi, Y.3
  • 13
    • 27144459401 scopus 로고    scopus 로고
    • Intracranial aneurysms at MR angiography: Effect of computer-aided diagnosis on radiologists' detection performance
    • Hirai T, Korogi Y, Arimura H, et al. Intracranial aneurysms at MR angiography: effect of computer-aided diagnosis on radiologists' detection performance. Radiology 2005; 237:605-610
    • (2005) Radiology , vol.237 , pp. 605-610
    • Hirai, T.1    Korogi, Y.2    Arimura, H.3
  • 14
    • 31844455031 scopus 로고    scopus 로고
    • Computerized detection of intracranial aneurysms for three-dimensional MR angiography: Feature extraction of small protrusions based on a shape-based difference image technique
    • Arimura H, Li Q, Korogi Y, et al. Computerized detection of intracranial aneurysms for three-dimensional MR angiography: feature extraction of small protrusions based on a shape-based difference image technique. Med Phys 2006; 33:394-401
    • (2006) Med Phys , vol.33 , pp. 394-401
    • Arimura, H.1    Li, Q.2    Korogi, Y.3
  • 15
    • 0041387385 scopus 로고    scopus 로고
    • Selective enhancement filters for nodules, vessels, and airway walls in two-and three-dimensional CT scans
    • Li Q, Sone S, Doi K. Selective enhancement filters for nodules, vessels, and airway walls in two-and three-dimensional CT scans. Med Phys 2003; 30:2040-2051
    • (2003) Med Phys , vol.30 , pp. 2040-2051
    • Li, Q.1    Sone, S.2    Doi, K.3
  • 16
    • 0034823999 scopus 로고    scopus 로고
    • ROC analysis of detection of metastatic pulmonary nodules on digital chest radiographs with temporal subtraction
    • Uozumi T, Nakamura K, Watanabe H, Nakata H, Katsuragawa S, Doi K. ROC analysis of detection of metastatic pulmonary nodules on digital chest radiographs with temporal subtraction. Acad Radiol 2001; 8:871-878
    • (2001) Acad Radiol , vol.8 , pp. 871-878
    • Uozumi, T.1    Nakamura, K.2    Watanabe, H.3    Nakata, H.4    Katsuragawa, S.5    Doi, K.6
  • 17
    • 0036082583 scopus 로고    scopus 로고
    • Improved detection of lung nodules by using a temporal subtraction technique
    • Kakeda S, Nakamura K, Kamada K, et al. Improved detection of lung nodules by using a temporal subtraction technique. Radiology 2002; 224:145-151
    • (2002) Radiology , vol.224 , pp. 145-151
    • Kakeda, S.1    Nakamura, K.2    Kamada, K.3
  • 18
    • 0032525017 scopus 로고    scopus 로고
    • Maximum-likelihood estimation of receiver operating (ROC) characteristic curves from continuously-distributed data
    • Metz CE, Herman BA, Shen JH. Maximum-likelihood estimation of receiver operating (ROC) characteristic curves from continuously-distributed data. Stat Med 1998; 17:1033-1053
    • (1998) Stat Med , vol.17 , pp. 1033-1053
    • Metz, C.E.1    Herman, B.A.2    Shen, J.H.3
  • 19
    • 0026664983 scopus 로고
    • Receiver operating characteristic rating analysis: Generalization to the population of readers and cases with the jackknife method
    • Dorfman DD, Berbaum KS, Metz CE. Receiver operating characteristic rating analysis: generalization to the population of readers and cases with the jackknife method. Invest Radiol 1992; 27:723-727
    • (1992) Invest Radiol , vol.27 , pp. 723-727
    • Dorfman, D.D.1    Berbaum, K.S.2    Metz, C.E.3
  • 20
    • 0030293525 scopus 로고    scopus 로고
    • Malignant and benign clustered microcalcifications: Automated feature analysis and classification
    • de Kort GA, Beijerinck D, Deurenberg JJ. Malignant and benign clustered microcalcifications: automated feature analysis and classification. Radiology 1996; 201:581-582
    • (1996) Radiology , vol.201 , pp. 581-582
    • de Kort, G.A.1    Beijerinck, D.2    Deurenberg, J.J.3
  • 21
    • 4644265703 scopus 로고    scopus 로고
    • Improvement in radiologists' characterization of malignant and benign breast masses on serial mammograms with computer-aided diagnosis: An ROC study
    • Hadjiiski L, Chan HP, Sahiner B, et al. Improvement in radiologists' characterization of malignant and benign breast masses on serial mammograms with computer-aided diagnosis: an ROC study. Radiology 2004; 233:255-265
    • (2004) Radiology , vol.233 , pp. 255-265
    • Hadjiiski, L.1    Chan, H.P.2    Sahiner, B.3
  • 22
    • 0036316503 scopus 로고    scopus 로고
    • Breast cancer: Effectiveness of computer-aided diagnosis observer study with independent database of mammograms
    • Huo Z, Giger ML, Vyborny CJ, Metz CE. Breast cancer: effectiveness of computer-aided diagnosis observer study with independent database of mammograms. Radiology 2002; 224:560-568
    • (2002) Radiology , vol.224 , pp. 560-568
    • Huo, Z.1    Giger, M.L.2    Vyborny, C.J.3    Metz, C.E.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.