-
1
-
-
0031908073
-
Oromandibular reconstruction using microvascular composite flaps: Report of 210 cases
-
Urken ML, Buchbinder D, Constantino PD, et al. Oromandibular reconstruction using microvascular composite flaps: report of 210 cases. Arch Otolaryngol Head Neck Surg 1998 124 : 46 55.
-
(1998)
Arch Otolaryngol Head Neck Surg
, vol.124
, pp. 46-55
-
-
Urken, M.L.1
Buchbinder, D.2
Constantino, P.D.3
-
2
-
-
0031915920
-
Use of the fixed mandibular implant in oral cancer patients: A retrospective study
-
August M, Bast B, Jackson M, Perrot D. Use of the fixed mandibular implant in oral cancer patients: a retrospective study. J Oral Maxillofac Surg 1994 56 : 297 301.
-
(1994)
J Oral Maxillofac Surg
, vol.56
, pp. 297-301
-
-
August, M.1
Bast, B.2
Jackson, M.3
Perrot, D.4
-
3
-
-
0035180234
-
Three-dimensional planning and simulation of hip operations and computer-assisted construction of endoprostheses in bone tumor surgery
-
Handels H, Ehrhardt J, Plotz W, Poppl SJ. Three-dimensional planning and simulation of hip operations and computer-assisted construction of endoprostheses in bone tumor surgery. Comput Aided Surg 2001 6 : 65 76.
-
(2001)
Comput Aided Surg
, vol.6
, pp. 65-76
-
-
Handels, H.1
Ehrhardt, J.2
Plotz, W.3
Poppl, S.J.4
-
4
-
-
0642365204
-
Three-dimensional simulation and prediction of craniofacial surgery
-
Meehan M, Teschner M, Girod S. Three-dimensional simulation and prediction of craniofacial surgery. Orthod Craniofac Res 2003 6 (Suppl 1 102 107.
-
(2003)
Orthod Craniofac Res
, vol.6
, Issue.1
, pp. 102-107
-
-
Meehan, M.1
Teschner, M.2
Girod, S.3
-
5
-
-
85026150644
-
The accuracy of stereolithography in planning craniofacial bone replacement
-
Chang PS, Parker TH, Patrick CW, Jr., Miller MJ. The accuracy of stereolithography in planning craniofacial bone replacement. J Craniofac Surg 2003 14 : 164 170.
-
(2003)
J Craniofac Surg
, vol.14
, pp. 164-170
-
-
Chang, P.S.1
Parker, T.H.2
Patrick Jr., C.W.3
Miller, M.J.4
-
6
-
-
21344474586
-
Zygomatic bone: Anatomic bases for osseointegrated implant anchorage
-
Rigolizzo MB, Camilli JA, Francischone CE, Padovani CR, Branemark PI. Zygomatic bone: anatomic bases for osseointegrated implant anchorage. Int J Oral Maxillofac Implants 2005 20 : 441 447.
-
(2005)
Int J Oral Maxillofac Implants
, vol.20
, pp. 441-447
-
-
Rigolizzo, M.B.1
Camilli, J.A.2
Francischone, C.E.3
Padovani, C.R.4
Branemark, P.I.5
-
7
-
-
4644226583
-
A clinical evaluation of the zygoma fixture: One year of follow-up at 16 clinics
-
Hirsch JM, Ohrnell LO, Henry PJ, et al. A clinical evaluation of the zygoma fixture: one year of follow-up at 16 clinics. J Oral Maxillofac Surg 2004 9 (Suppl 2 22 29.
-
(2004)
J Oral Maxillofac Surg
, vol.9
, Issue.2
, pp. 22-29
-
-
Hirsch, J.M.1
Ohrnell, L.O.2
Henry, P.J.3
-
8
-
-
0025471133
-
The longitudinal clinical effectiveness of osseointegrated dental implants: The Toronto study. Part III: Problems and complications encountered
-
Zarb GA, Schmitt AJ. The longitudinal clinical effectiveness of osseointegrated dental implants: the Toronto study. Part III: problems and complications encountered. Prosthet Dent 1990 64 : 185 194.
-
(1990)
Prosthet Dent
, vol.64
, pp. 185-194
-
-
Zarb, G.A.1
Schmitt, A.J.2
-
9
-
-
0022671214
-
Development of carbon/graphite fiber reinforced poly (methyl methacrylate) suitable for implant-fixed dental bridges
-
Reuter IE, Ekstrand K, Bjork N. Development of carbon/graphite fiber reinforced poly (methyl methacrylate) suitable for implant-fixed dental bridges. Dent Mater 1986 2 : 6 9.
-
(1986)
Dent Mater
, vol.2
, pp. 6-9
-
-
Reuter, I.E.1
Ekstrand, K.2
Bjork, N.3
-
10
-
-
27144498577
-
Evaluation of two matrix materials intended for fiber-reinforced polymers
-
Segerstrom S, Meric G, Knarvang T, Ruyter IE. Evaluation of two matrix materials intended for fiber-reinforced polymers. Eur J Oral Sci 2005 113 : 422 428.
-
(2005)
Eur J Oral Sci
, vol.113
, pp. 422-428
-
-
Segerstrom, S.1
Meric, G.2
Knarvang, T.3
Ruyter, I.E.4
-
11
-
-
0141463995
-
The evolution of the obturator framework design
-
Parr GR, Gardner LK. The evolution of the obturator framework design. J Prosthet Dent 2003 89 : 608 610.
-
(2003)
J Prosthet Dent
, vol.89
, pp. 608-610
-
-
Parr, G.R.1
Gardner, L.K.2
-
12
-
-
25144453316
-
Bone invasion in patients with oral cavity cancer: Comparison of conventional CT and with PET/CT and SPECT/CT
-
Goerres GW, Schmid DT, Schuknecht B, Eyrich GK. Bone invasion in patients with oral cavity cancer: comparison of conventional CT and with PET/CT and SPECT/CT. Radiology 2005 237 : 281 287.
-
(2005)
Radiology
, vol.237
, pp. 281-287
-
-
Goerres, G.W.1
Schmid, D.T.2
Schuknecht, B.3
Eyrich, G.K.4
-
13
-
-
28844444631
-
Navigational maxillofacial surgery using virtual models
-
Hohlweg-Majert B, Schon R, Schmelzeisen R, Gellrich NC, Schramm A. Navigational maxillofacial surgery using virtual models. World J Surg 2005 29 : 1530 1538.
-
(2005)
World J Surg
, vol.29
, pp. 1530-1538
-
-
Hohlweg-Majert, B.1
Schon, R.2
Schmelzeisen, R.3
Gellrich, N.C.4
Schramm, A.5
-
14
-
-
0031068546
-
Clinical evaluation of implants retaining edentulous maxillary obturator prostheses
-
III.
-
Roumanas ED, Nishimura RD, Davis BK, Beumer J, III. Clinical evaluation of implants retaining edentulous maxillary obturator prostheses. J Prosthet Dent 1997 77 : 184 190.
-
(1997)
J Prosthet Dent
, vol.77
, pp. 184-190
-
-
Roumanas, E.D.1
Nishimura, R.D.2
Davis, B.K.3
Beumer, J.4
-
16
-
-
18044385002
-
Osseointegration in irradiated cancer patients: An analysis with respect to implant failures
-
Granstrom GJ. Osseointegration in irradiated cancer patients: an analysis with respect to implant failures. Oral Maxillofac Surg 2005 63 : 579 585.
-
(2005)
Oral Maxillofac Surg
, vol.63
, pp. 579-585
-
-
Granstrom, G.J.1
-
18
-
-
34447645793
-
Mechanical and physical properties of carbon-graphite fiber reinforced polymers intended for implant superstructures
-
Segerstrom S, Ruyter IE. Mechanical and physical properties of carbon-graphite fiber reinforced polymers intended for implant superstructures. Dent Mater 2007 23 (9 1150 1156.
-
(2007)
Dent Mater
, vol.23
, Issue.9
, pp. 1150-1156
-
-
Segerstrom, S.1
Ruyter, I.E.2
|