메뉴 건너뛰기




Volumn 35, Issue 2, 2008, Pages 617-628

A needle guidance system for biopsy and therapy using two-dimensional ultrasound

Author keywords

Biopsy; Image guided therapy; Ultrasound guidance

Indexed keywords

ANIMALS; BIOPSY; ELECTRONIC GUIDANCE SYSTEMS; MEDICAL IMAGING; PHANTOMS; REMOTE CONTROL; TISSUE; TRAJECTORIES; ULTRASONIC APPLICATIONS;

EID: 38849167383     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.2829871     Document Type: Article
Times cited : (24)

References (24)
  • 1
    • 0033966483 scopus 로고    scopus 로고
    • Ultrasound of the breast
    • 0364-2313
    • M. B. Kossoff, " Ultrasound of the breast., " World J. Surg. 24, 143-157 (2000). 0364-2313
    • (2000) World J. Surg. , vol.24 , pp. 143-157
    • Kossoff, M.B.1
  • 2
    • 0036828885 scopus 로고    scopus 로고
    • Preferential use of sonographically guided biopsy to minimize patient discomfort and procedure time in a percutaneous image-guided breast biopsy program
    • 0278-4297
    • M. B. Mainiero, " Preferential use of sonographically guided biopsy to minimize patient discomfort and procedure time in a percutaneous image-guided breast biopsy program., " J. Ultrasound Med. 21, 1221-1226 (2002). 0278-4297
    • (2002) J. Ultrasound Med. , vol.21 , pp. 1221-1226
    • Mainiero, M.B.1
  • 4
    • 35649022171 scopus 로고    scopus 로고
    • Stereotactic mammography imaging combined with 3D US imaging for image guided breast biopsy
    • 0094-2405 10.1118/1.2794175
    • K. J. M. Surry, " Stereotactic mammography imaging combined with 3D US imaging for image guided breast biopsy., " Med. Phys. 0094-2405 10.1118/1.2794175 34, 4348-4358 (2007).
    • (2007) Med. Phys. , vol.34 , pp. 4348-4358
    • Surry, K.J.M.1
  • 5
    • 0036829214 scopus 로고    scopus 로고
    • A steerable guiding device-The new method in ultrasound guidance
    • 0020-9996
    • D. Han, " A steerable guiding device-The new method in ultrasound guidance., " Invest. Radiol. 37, 626-631 (2002). 0020-9996
    • (2002) Invest. Radiol. , vol.37 , pp. 626-631
    • Han, D.1
  • 6
    • 0036226228 scopus 로고    scopus 로고
    • A new device for free-hand, obstetric ultrasound-guided procedures
    • 0960-7692
    • Y. Paltieli, " A new device for free-hand, obstetric ultrasound-guided procedures., " Ultrasound Obstet. Gynecol. 19, 269-273 (2002). 0960-7692
    • (2002) Ultrasound Obstet. Gynecol. , vol.19 , pp. 269-273
    • Paltieli, Y.1
  • 7
  • 8
    • 0036754876 scopus 로고    scopus 로고
    • Augmented reality guidance for needle biopsies: An initial randomized, controlled trial in phantoms
    • 1361-8415
    • M. Rosenthal, " Augmented reality guidance for needle biopsies: An initial randomized, controlled trial in phantoms., " Med. Image Anal. 6, 313-320 (2002). 1361-8415
    • (2002) Med. Image Anal. , vol.6 , pp. 313-320
    • Rosenthal, M.1
  • 9
    • 0025008966 scopus 로고
    • US guidance of interventional procedures
    • 0033-8419
    • T. A. S. Matalon and B. Silver, " US guidance of interventional procedures., " Radiology 174, 43-47 (1990). 0033-8419
    • (1990) Radiology , vol.174 , pp. 43-47
    • Matalon, T.A.S.1    Silver, B.2
  • 10
    • 33744811412 scopus 로고    scopus 로고
    • Lesion detection and characterization in a breast us phantom: Results of the acrin 6666 investigators
    • 0033-8419
    • W. A. Berg, " Lesion detection and characterization in a breast us phantom: Results of the acrin 6666 investigators., " Radiology 239, 693-702 (2006). 0033-8419
    • (2006) Radiology , vol.239 , pp. 693-702
    • Berg, W.A.1
  • 11
    • 0029677187 scopus 로고    scopus 로고
    • Freehand interventional sonography in the breast: Basic principles and applications
    • 0271-5333
    • D. Georgian-Smith and W. E. Sheils, " Freehand interventional sonography in the breast: Basic principles and applications., " Radiographics 16, 149-161 (1996). 0271-5333
    • (1996) Radiographics , vol.16 , pp. 149-161
    • Georgian-Smith, D.1    Sheils, W.E.2
  • 12
    • 0001989307 scopus 로고    scopus 로고
    • Real time spatial compound imaging in breast ultrasound: Technology and early clinical experience
    • R. Entrekin, " Real time spatial compound imaging in breast ultrasound: Technology and early clinical experience., " Med. Mundi 43, 35-43 (1999).
    • (1999) Med. Mundi , vol.43 , pp. 35-43
    • Entrekin, R.1
  • 13
    • 1442274863 scopus 로고    scopus 로고
    • Objective measurements of image quality
    • 0301-5629 10.1016/j.ultrasmedbio.2003.10.002
    • J. E. Browne, " Objective measurements of image quality., " Ultrasound Med. Biol. 0301-5629 10.1016/j.ultrasmedbio.2003.10.002 30, 229-237 (2004).
    • (2004) Ultrasound Med. Biol. , vol.30 , pp. 229-237
    • Browne, J.E.1
  • 14
    • 0028784526 scopus 로고
    • A wall-less vessel phantom for doppler ultrasound studies
    • 0301-5629 10.1016/0301-5629(95)00044-5
    • D. W. Rickey, " A wall-less vessel phantom for doppler ultrasound studies., " Ultrasound Med. Biol. 0301-5629 10.1016/0301-5629(95)00044-5 21, 1163-76 (1995).
    • (1995) Ultrasound Med. Biol. , vol.21 , pp. 1163-1176
    • Rickey, D.W.1
  • 15
    • 12744271954 scopus 로고    scopus 로고
    • Poly(vinyl alcohol) cryogel phantoms for use in ultrasound and mr imaging
    • 0031-9155 10.1088/0031-9155/49/24/009
    • K. J. M. Surry, " Poly(vinyl alcohol) cryogel phantoms for use in ultrasound and mr imaging., " Phys. Med. Biol. 0031-9155 10.1088/0031-9155/49/24/009 49, 5529-5546 (2004).
    • (2004) Phys. Med. Biol. , vol.49 , pp. 5529-5546
    • Surry, K.J.M.1
  • 16
    • 17844390697 scopus 로고    scopus 로고
    • Brachytherapy needle deflection evaluation and correction
    • 0094-2405 10.1118/1.1871372
    • G. Wan, " Brachytherapy needle deflection evaluation and correction., " Med. Phys. 0094-2405 10.1118/1.1871372 32, 902-909 (2005).
    • (2005) Med. Phys. , vol.32 , pp. 902-909
    • Wan, G.1
  • 17
    • 0022808786 scopus 로고
    • Computational approach to edge detection
    • 0162-8828
    • J. Canny, " Computational approach to edge detection., " IEEE Trans. Pattern Anal. Mach. Intell. 8, 679-698 (1986). 0162-8828
    • (1986) IEEE Trans. Pattern Anal. Mach. Intell. , vol.8 , pp. 679-698
    • Canny, J.1
  • 19
    • 85027228871 scopus 로고    scopus 로고
    • Registered 3d-ultrasound and digital stereotactic mammography for breast biopsy guidance
    • M. R. Irwin, D. B. Downey, L. Gardi, and A. Fenster, " Registered 3d-ultrasound and digital stereotactic mammography for breast biopsy guidance., " IEEE Trans. Med. Imaging (in press).
    • IEEE Trans. Med. Imaging
    • Irwin, M.R.1    Downey, D.B.2    Gardi, L.3    Fenster, A.4
  • 21
    • 0036754312 scopus 로고    scopus 로고
    • The development and evaluation of a three-dimensional ultrasound guided breast biopsy apparatus
    • 1361-8415 10.1016/S1361-8415(02)00087-7
    • K. J. M. Surry, W. L. Smith, and L. J. Campbell, " The development and evaluation of a three-dimensional ultrasound guided breast biopsy apparatus., " Med. Image Anal. 1361-8415 10.1016/S1361-8415(02)00087-7 6, 301-312 (2002).
    • (2002) Med. Image Anal. , vol.6 , pp. 301-312
    • Surry, K.J.M.1    Smith, W.L.2    Campbell, L.J.3
  • 22
    • 0042347845 scopus 로고    scopus 로고
    • Training module to teach ultrasound-guided breast biopsy skills to residents improves accuracy
    • 0846-5371
    • M. K. Hassard, " Training module to teach ultrasound-guided breast biopsy skills to residents improves accuracy., " Can. Assoc. Radiol. J. 54, 155-159 (2003). 0846-5371
    • (2003) Can. Assoc. Radiol. J. , vol.54 , pp. 155-159
    • Hassard, M.K.1
  • 23
    • 0031205261 scopus 로고    scopus 로고
    • Evaluation of a turkey-breast phantom for teaching freehand, us-guided core needle breast biopsy
    • 1076-6332
    • J. A. Harvey, " Evaluation of a turkey-breast phantom for teaching freehand, us-guided core needle breast biopsy., " Acad. Radiol. 4, 565-569 (1997). 1076-6332
    • (1997) Acad. Radiol. , vol.4 , pp. 565-569
    • Harvey, J.A.1
  • 24
    • 0036232744 scopus 로고    scopus 로고
    • Comparison of core needle breast biopsy techniques: Freehand versus three-dimensional us guidance
    • 1076-6332
    • W. L. Smith, " Comparison of core needle breast biopsy techniques: Freehand versus three-dimensional us guidance., " Acad. Radiol. 9, 541-550 (2002). 1076-6332
    • (2002) Acad. Radiol. , vol.9 , pp. 541-550
    • Smith, W.L.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.