메뉴 건너뛰기




Volumn 3, Issue , 2006, Pages 1752-1756

Iterative kinetic parameter estimation within fully 4D PET image reconstruction

Author keywords

[No Author keywords available]

Indexed keywords

ITERATIVE METHODS; KINETIC PARAMETERS; MAXIMUM LIKELIHOOD ESTIMATION; PARAMETER ESTIMATION; POSITRON EMISSION TOMOGRAPHY; STATISTICS;

EID: 38649129133     PISSN: 10957863     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/NSSMIC.2006.354235     Document Type: Conference Paper
Times cited : (32)

References (8)
  • 1
    • 0036525894 scopus 로고    scopus 로고
    • Spatiotemporal reconstruction of list-mode PET data
    • T. E. Nichols, J. Qi, E. Asma, and R. M. Leahy, "Spatiotemporal reconstruction of list-mode PET data," IEEE Trans. Med. Imaging vol. 21 pp. 396-404, 2002.
    • (2002) IEEE Trans. Med. Imaging , vol.21 , pp. 396-404
    • Nichols, T.E.1    Qi, J.2    Asma, E.3    Leahy, R.M.4
  • 2
    • 18844431381 scopus 로고    scopus 로고
    • M. E. Kamasak, C. A. Bouman, E. D. Morris, and K. Sauer K, Direct reconstruction of kinetic parameter images from dynamic PET data, IEEE Trans. Med. Imaging 24 pp. 636-50, 2005.
    • M. E. Kamasak, C. A. Bouman, E. D. Morris, and K. Sauer K, "Direct reconstruction of kinetic parameter images from dynamic PET data," IEEE Trans. Med. Imaging vol. 24 pp. 636-50, 2005.
  • 3
    • 0020194763 scopus 로고
    • Maximum likelihood reconstruction for emission tomography
    • L. A. Shepp and Y. Vardi "Maximum likelihood reconstruction for emission tomography" IEEE Trans. Med. Im, vol. 1, pp.113-122, 1982.
    • (1982) IEEE Trans. Med. Im , vol.1 , pp. 113-122
    • Shepp, L.A.1    Vardi, Y.2
  • 4
    • 0035017354 scopus 로고    scopus 로고
    • 4D maximum a posteriori reconstruction in dynamic SPECT using a compartmental model-based prior
    • D. J. Kadrmas, and G. T. Gullberg, "4D maximum a posteriori reconstruction in dynamic SPECT using a compartmental model-based prior" Phys. Med. Biol. vol. 46 pp. 1553-74, 2001.
    • (2001) Phys. Med. Biol , vol.46 , pp. 1553-1574
    • Kadrmas, D.J.1    Gullberg, G.T.2
  • 5
    • 0036464422 scopus 로고    scopus 로고
    • K. Wienhard K, M. Schmand, M. E. Casey, K. Baker, J. Bao, L. Eriksson, W. F. Jones, C. Knoess, M. Lenox, M. Lercher, P. Luk, C. Michel, J. H. Reed, N. Richerzhagen, J. Treffert, S. Vollmar, J. W. Young, W. D. Heiss, and R. Nutt, The ECAT HRRT: Performance and first clinical application of the new High Resolution Research Tomograph, IEEE Trans. Nucl. Sci. 49 pp. 104-10, 2002.
    • K. Wienhard K, M. Schmand, M. E. Casey, K. Baker, J. Bao, L. Eriksson, W. F. Jones, C. Knoess, M. Lenox, M. Lercher, P. Luk, C. Michel, J. H. Reed, N. Richerzhagen, J. Treffert, S. Vollmar, J. W. Young, W. D. Heiss, and R. Nutt, "The ECAT HRRT: Performance and first clinical application of the new High Resolution Research Tomograph," IEEE Trans. Nucl. Sci. vol. 49 pp. 104-10, 2002.
  • 6
    • 0034971675 scopus 로고    scopus 로고
    • A fast nonlinear method for parametric imaging of myocardial perfusion by dynamic 13N-ammonia PET
    • S. R. Golish, J. D. Hove, H. R. Schelbert, and S. S. Gambhir, "A fast nonlinear method for parametric imaging of myocardial perfusion by dynamic 13N-ammonia PET," J. Nucl. Med. vol. 42 no 6 pp. 924-931, 2001.
    • (2001) J. Nucl. Med , vol.42 , Issue.6 , pp. 924-931
    • Golish, S.R.1    Hove, J.D.2    Schelbert, H.R.3    Gambhir, S.S.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.