메뉴 건너뛰기




Volumn 53, Issue 2, 2008, Pages 341-346

Dilation of benign strictures in the esophagus and colon with the polyflex stent: A case series study

Author keywords

Benign gastrointestinal strictures; Dilation; Polyflex stent; Stents

Indexed keywords

ADULT; AGED; ARTICLE; CLINICAL ARTICLE; COLON TUMOR; CONTROLLED STUDY; DISEASE SEVERITY; ESOPHAGUS OBSTRUCTION; ESOPHAGUS STRICTURE; FEMALE; HUMAN; MALE; PAIN; PRIORITY JOURNAL; STENT;

EID: 38649127907     PISSN: 01632116     EISSN: None     Source Type: Journal    
DOI: 10.1007/s10620-007-9864-7     Document Type: Article
Times cited : (46)

References (17)
  • 2
    • 4444376993 scopus 로고    scopus 로고
    • Endoscopic dilation of benign colorectal anastomotic stricture after low anterior resection: A prospective comparison study of two balloon types
    • Di Giorgio P, De Luca L, Rivellini G, Sorrentino E, D'Amore E, De Luca B (2004) Endoscopic dilation of benign colorectal anastomotic stricture after low anterior resection: a prospective comparison study of two balloon types. Gastrointestinal Endoscopy 60:347-350
    • (2004) Gastrointest Endosc , vol.60 , pp. 347-350
    • Di Giorgio, P.1    De Luca, L.2    Rivellini, G.3    Sorrentino, E.4    D'Amore, E.5    De Luca, B.6
  • 3
    • 0029048723 scopus 로고
    • Preliminary experience with endoscopic intralesional steroid injection therapy for refractory upper gastrointestinal strictures
    • Lee M, Kubik CM, Polhamus CD, Brady CE, Kadakia SC (1995) Preliminary experience with endoscopic intralesional steroid injection therapy for refractory upper gastrointestinal strictures. Gastrointest Endosc 41:598-601
    • (1995) Gastrointest Endosc , vol.41 , pp. 598-601
    • Lee, M.1    Kubik, C.M.2    Polhamus, C.D.3    Brady, C.E.4    Kadakia, S.C.5
  • 4
    • 0035315815 scopus 로고    scopus 로고
    • Endoscopic stricture incision of a postoperative colonic Gastrointestinal
    • Dieruf LM, Prakash C (2001) Endoscopic stricture incision of a postoperative colonic Gastrointestinal. Endoscopy 53:522-524
    • (2001) Endoscopy , vol.53 , pp. 522-524
    • Dieruf, L.M.1    Prakash, C.2
  • 5
    • 0041386363 scopus 로고    scopus 로고
    • Esophageal stenting in unusual situations
    • Shim CS (2003) Esophageal stenting in unusual situations. Endoscopy 35:14-18
    • (2003) Endoscopy , vol.35 , pp. 14-18
    • Shim, C.S.1
  • 6
    • 0037981238 scopus 로고    scopus 로고
    • Prospective evaluation of a new self-expanding plastic stent for inoperable esophageal strictures
    • Costamagna G, Shah SK, Tringali A, Mutignani M, Perri V, Riccioni ME (2003) Prospective evaluation of a new self-expanding plastic stent for inoperable esophageal strictures. Surg Endosc 17:891-895
    • (2003) Surg Endosc , vol.17 , pp. 891-895
    • Costamagna, G.1    Shah, S.K.2    Tringali, A.3    Mutignani, M.4    Perri, V.5    Riccioni, M.E.6
  • 7
    • 0035202984 scopus 로고    scopus 로고
    • Use of the Polyflex stent in the palliative therapy of esophageal carcinoma: Results in 14 cases and review of the literature
    • Decker P, Lippler J, Decker D, Hirner A (2001) Use of the Polyflex stent in the palliative therapy of esophageal carcinoma: results in 14 cases and review of the literature. Surg Endosc 15:1444-1447
    • (2001) Surg Endosc , vol.15 , pp. 1444-1447
    • Decker, P.1    Lippler, J.2    Decker, D.3    Hirner, A.4
  • 8
    • 33847191767 scopus 로고    scopus 로고
    • Expandable polyester silicon-covered stent for malignant esophageal structures before neoadjuvant chemoradiation: A pilot study
    • Siddiqui AA, Loren D, Dudnick R, Kowalski T (2007). Expandable polyester silicon-covered stent for malignant esophageal structures before neoadjuvant chemoradiation: a pilot study. Dig Dis Sci 52:823-829
    • (2007) Dig Dis Sci , vol.52 , pp. 823-829
    • Siddiqui, A.A.1    Loren, D.2    Dudnick, R.3    Kowalski, T.4
  • 9
    • 17644410414 scopus 로고    scopus 로고
    • Esophageal insertion of Polyflex stents without fluoroscopy in peptic strictures
    • García-Cano J (2005) Esophageal insertion of Polyflex stents without fluoroscopy in peptic strictures. Endoscopy 37:400
    • (2005) Endoscopy , vol.37 , pp. 400
    • García-Cano, J.1
  • 10
    • 0035072497 scopus 로고    scopus 로고
    • Successful treatment of esophageal perforation with a removable self-expanding plastic stent
    • Dormann AJ, Wigginghaus B, Deppe H, Huchzermeyer H (2001) Successful treatment of esophageal perforation with a removable self-expanding plastic stent. Am J Gastroenterol 96:923-924
    • (2001) Am J Gastroenterol , vol.96 , pp. 923-924
    • Dormann, A.J.1    Wigginghaus, B.2    Deppe, H.3    Huchzermeyer, H.4
  • 11
    • 11844304333 scopus 로고    scopus 로고
    • Colorectal anastomotic strictures: Treatment by fluoroscopic double balloon dilation
    • Di A-H, Shin JH, Kim JH, Song H-Y (2005) Colorectal anastomotic strictures: treatment by fluoroscopic double balloon dilation. J Vasc Interv Radiol 16:75-80
    • (2005) J Vasc Interv Radiol , vol.16 , pp. 75-80
    • Di, A.-H.1    Shin, J.H.2    Kim, J.H.3    Song, H.-Y.4
  • 12
    • 33646746359 scopus 로고    scopus 로고
    • Failure of self-expanding plastic stents in treatment of refractory benign esophageal strictures
    • Triester SL, Fleischer DE, Sharma VK (2006) Failure of self-expanding plastic stents in treatment of refractory benign esophageal strictures. Endoscopy 38: 533-537
    • (2006) Endoscopy , vol.38 , pp. 533-537
    • Triester, S.L.1    Fleischer, D.E.2    Sharma, V.K.3
  • 13
    • 33845224576 scopus 로고    scopus 로고
    • Polyflex stent for relief of obstruction in a patient with a benign anastomotic colonic stricture and description of non-fluoroscopic technique
    • Arora M, Okolo P (2006) Polyflex stent for relief of obstruction in a patient with a benign anastomotic colonic stricture and description of non-fluoroscopic technique. Gastroenterol & Hepatol 10:766-768
    • (2006) Gastroenterol Hepatol , vol.10 , pp. 766-768
    • Arora, M.1    Okolo, P.2
  • 14
    • 25644457693 scopus 로고    scopus 로고
    • The use of a Polyflex coated esophageal stent to assist in the closure of a colonic anastomotic leak
    • Scileppi T, Li JJ, Iswara K, Tenner S (2005) The use of a Polyflex coated esophageal stent to assist in the closure of a colonic anastomotic leak. Gastrointestinal Endoscopy 62:643-645
    • (2005) Gastrointest Endosc , vol.62 , pp. 643-645
    • Scileppi, T.1    Li, J.J.2    Iswara, K.3    Tenner, S.4
  • 15
    • 33748072754 scopus 로고    scopus 로고
    • Self-expanding silicone stent for treatment of postoperative colorectal stricture in an infant with Hirschsprung's disease: A case report
    • Rullán R, Danielson P, Hirsh M, Kim D, Eckardt A, Bhattacharya K (2006) Self-expanding silicone stent for treatment of postoperative colorectal stricture in an infant with Hirschsprung's disease: a case report. J Pediatr Surg 41:1613-1615
    • (2006) J Pediatr Surg , vol.41 , pp. 1613-1615
    • Rullán, R.1    Danielson, P.2    Hirsh, M.3    Kim, D.4    Eckardt, A.5    Bhattacharya, K.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.