메뉴 건너뛰기




Volumn 1, Issue , 2006, Pages 264-269

A directional algorithm for an electronically-collimated gamma-ray detector

Author keywords

[No Author keywords available]

Indexed keywords

ALGORITHMS; COMPTON SCATTERING; GAMMA RAYS; OPTICAL COLLIMATORS; RANDOM PROCESSES; SAFETY ENGINEERING;

EID: 38649106507     PISSN: 10957863     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/NSSMIC.2006.356152     Document Type: Conference Paper
Times cited : (4)

References (8)
  • 2
    • 0033317713 scopus 로고    scopus 로고
    • Angular uncertainties due to geometry and spatial resolution in Compton cameras
    • C. Ordonez, W. Chang and A. Bolozdynya, "Angular uncertainties due to geometry and spatial resolution in Compton cameras," IEEE Trans. Nucl. Sci., vol. 46, no. 4, pp. 1142-1147, 1999.
    • (1999) IEEE Trans. Nucl. Sci , vol.46 , Issue.4 , pp. 1142-1147
    • Ordonez, C.1    Chang, W.2    Bolozdynya, A.3
  • 3
    • 0035151358 scopus 로고    scopus 로고
    • Evaluation of a Compton scattering camera using 3-D position sensitive CdZnTe detectors
    • Y. Du, Z. He, G. Knoll, D. Wehe and W. Li, "Evaluation of a Compton scattering camera using 3-D position sensitive CdZnTe detectors," Nucl. Instrum. Methods Phys. Res. A, vol. 457, pp. 203-211, 2001.
    • (2001) Nucl. Instrum. Methods Phys. Res. A , vol.457 , pp. 203-211
    • Du, Y.1    He, Z.2    Knoll, G.3    Wehe, D.4    Li, W.5
  • 4
    • 84942765363 scopus 로고    scopus 로고
    • Compton Cameras for Nuclear Medical Imaging
    • M.N. Wernick and J.N. Aarsvold, Eds. San Diego: Elsevier Academic Press
    • W.L. Rogers, N.H. Clinthorne, and A. Bolozdynya, "Compton Cameras for Nuclear Medical Imaging," in Emission Tomography, The Fundamentals of PET and SPECT, M.N. Wernick and J.N. Aarsvold, Eds. San Diego: Elsevier Academic Press, 2004, pp. 383-419.
    • (2004) Emission Tomography, The Fundamentals of PET and SPECT , pp. 383-419
    • Rogers, W.L.1    Clinthorne, N.H.2    Bolozdynya, A.3
  • 5
    • 38649110865 scopus 로고    scopus 로고
    • Filtered Backprojection Algorithms for Compton Cameras in Nuclear
    • unpublished
    • D.L. Gunter, "Filtered Backprojection Algorithms for Compton Cameras in Nuclear Medicine," unpublished.
    • Medicine
    • Gunter, D.L.1
  • 7
    • 0034245169 scopus 로고    scopus 로고
    • Reconstruction of Cone-Beam Projections From Compton Scattered Data
    • L.C. Parra, "Reconstruction of Cone-Beam Projections From Compton Scattered Data," IEEE Transactions on Nuclear Science, vol. 47, no. 4, pp. 1543-1550, 2000.
    • (2000) IEEE Transactions on Nuclear Science , vol.47 , Issue.4 , pp. 1543-1550
    • Parra, L.C.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.