메뉴 건너뛰기




Volumn 52, Issue 4, 2007, Pages 271-280

A novel method to determine oxidation rates of heritage materials in vitro and in situ

Author keywords

[No Author keywords available]

Indexed keywords

CORROSION RATE; OPTICAL SENSORS; OXYGEN SENSORS;

EID: 38549160538     PISSN: 00393630     EISSN: None     Source Type: Journal    
DOI: 10.1179/sic.2007.52.4.271     Document Type: Article
Times cited : (31)

References (9)
  • 1
    • 85036978533 scopus 로고    scopus 로고
    • Grattan, D.W., 'Degradation rates for some historic polymers and the potential of various conservation measures for minimizing oxidative degradation', in Saving the Twentieth Century: The Conservation of Modern Material, Proceedings of a Conference Symposium, Ottawa, 15-20 September 1991, ed. D.W Grattan, Canadian Conservation Institute, Ottawa (1993) 351-361.
    • Grattan, D.W., 'Degradation rates for some historic polymers and the potential of various conservation measures for minimizing oxidative degradation', in Saving the Twentieth Century: The Conservation of Modern Material, Proceedings of a Conference Symposium, Ottawa, 15-20 September 1991, ed. D.W Grattan, Canadian Conservation Institute, Ottawa (1993) 351-361.
  • 2
    • 0035046389 scopus 로고    scopus 로고
    • Study of the photooxidation of mass-deacified papers
    • Dufour, J., and Havermans, J.B.G.A., 'Study of the photooxidation of mass-deacified papers', Restaurator 22 (2001) 20-40.
    • (2001) Restaurator , vol.22 , pp. 20-40
    • Dufour, J.1    Havermans, J.B.G.A.2
  • 6
    • 0007958306 scopus 로고
    • A review of oxygen uptake techniques for measuring polyolefin oxidation
    • Scheirs, J., Bigger, S.W., and Billingham, N., 'A review of oxygen uptake techniques for measuring polyolefin oxidation', Polymer Testing 14 (1995) 211-214.
    • (1995) Polymer Testing , vol.14 , pp. 211-214
    • Scheirs, J.1    Bigger, S.W.2    Billingham, N.3
  • 7
    • 27844523675 scopus 로고    scopus 로고
    • Use of a respirometer to measure oxidation rates of polymeric materials at ambient temperatures
    • Assink, R.A., Celina, M., Skutnik, J.M., and Harris, D.J., 'Use of a respirometer to measure oxidation rates of polymeric materials at ambient temperatures', Polymer 46 (2005) 11648-11654.
    • (2005) Polymer , vol.46 , pp. 11648-11654
    • Assink, R.A.1    Celina, M.2    Skutnik, J.M.3    Harris, D.J.4
  • 9
    • 0028491395 scopus 로고
    • Scanning optical sensor for the measurement of dissolved oxygen and BOD
    • Li, X.-M., Ruan, F.-C., Ng, W.-Y., and Wong, K.-Y., 'Scanning optical sensor for the measurement of dissolved oxygen and BOD', Sensors and Actuators B 21 (1994) 143-149.
    • (1994) Sensors and Actuators B , vol.21 , pp. 143-149
    • Li, X.-M.1    Ruan, F.-C.2    Ng, W.-Y.3    Wong, K.-Y.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.