메뉴 건너뛰기




Volumn 5, Issue , 2006, Pages 2854-2858

SPECT image quality and quantification

Author keywords

[No Author keywords available]

Indexed keywords

IMAGE QUALITY; IMAGE RECONSTRUCTION; ITERATIVE METHODS; OPTIMIZATION; SIGNAL TO NOISE RATIO; STATISTICAL METHODS;

EID: 38549157549     PISSN: 10957863     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/NSSMIC.2006.356472     Document Type: Conference Paper
Times cited : (8)

References (9)
  • 1
    • 33746362600 scopus 로고    scopus 로고
    • Analytical Model for SPECT Detector Concepts
    • H. Wieczorek, A. Goedicke, "Analytical Model for SPECT Detector Concepts", IEEE Trans. Nuclear Sci., vol. 53, pp. 1102-1112, 2006
    • (2006) IEEE Trans. Nuclear Sci , vol.53 , pp. 1102-1112
    • Wieczorek, H.1    Goedicke, A.2
  • 4
    • 23844545136 scopus 로고    scopus 로고
    • 2004 IEEE Nuclear Science Conference Record
    • A. Goedicke, H. Wieczorek, L. Shao, M. Petrillo, J. Ye, and J. Vesel, "Image Quality Assessment of Pixellated Systems", 2004 IEEE Nuclear Science Conference Record, M10-304, pp. 4058-4062, 2004
    • (2004)
    • Goedicke, A.1    Wieczorek, H.2    Shao, L.3    Petrillo, M.4    Ye, J.5    Vesel, J.6
  • 5
    • 0017452940 scopus 로고
    • A Method for Attenuation Correction in Radionuclide Computed Tomography
    • L. T. Chang, "A Method for Attenuation Correction in Radionuclide Computed Tomography", IEEE Trans. Nuclear Sci., vol. NS25, pp. 638-648, 1978
    • (1978) IEEE Trans. Nuclear Sci , vol.NS25 , pp. 638-648
    • Chang, L.T.1
  • 6
    • 0001299320 scopus 로고
    • G. J. Hine, J. A. Sorenson, Ed, Academic, New York
    • J. A. Sorenson, Instrumentation in Nuclear Medicine, vol. 2, G. J. Hine, J. A. Sorenson, Ed., Academic, New York: 1974, pp. 311-348
    • (1974) Instrumentation in Nuclear Medicine , vol.2 , pp. 311-348
    • Sorenson, J.A.1
  • 7
    • 0036624498 scopus 로고    scopus 로고
    • The Effects of Incorrect Modeling on Noise and Resolution Properties of ML-EM Images
    • D. W. Wilson, H. H. Barrett, "The Effects of Incorrect Modeling on Noise and Resolution Properties of ML-EM Images", IEEE Trans. Nuclear Sci., vol. 49, pp. 768-773, 2002
    • (2002) IEEE Trans. Nuclear Sci , vol.49 , pp. 768-773
    • Wilson, D.W.1    Barrett, H.H.2
  • 8
    • 0028309681 scopus 로고
    • Noise Properties of the EM Algorithm: II. Monte Carlo Simulations
    • H. H. Barrett, D. W. Wilson, B. M. W. Tsui, "Noise Properties of the EM Algorithm: II. Monte Carlo Simulations", Phys. Med. Biol., vol. 39, pp. 847-871, 1994
    • (1994) Phys. Med. Biol , vol.39 , pp. 847-871
    • Barrett, H.H.1    Wilson, D.W.2    Tsui, B.M.W.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.