메뉴 건너뛰기




Volumn 5, Issue , 2006, Pages 2791-2795

Dynamic list-mode reconstruction of PET data based on the ML-EM algorithm

Author keywords

ClearPET Neuro; Dynamic reconstruction; List mode; PET

Indexed keywords

ALGORITHMS; DYNAMIC PROGRAMMING; IMAGE RESOLUTION; POSITRON EMISSION TOMOGRAPHY; TEMPORAL LOGIC;

EID: 38549123374     PISSN: 10957863     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/NSSMIC.2006.356458     Document Type: Conference Paper
Times cited : (3)

References (12)
  • 4
    • 0020194763 scopus 로고
    • Maximum likelihood reconstruction for emission tomography
    • L. Shepp and Y. Vardi, "Maximum likelihood reconstruction for emission tomography", IEEE Transactions on Medical Imaging, MI-1, 113-122, 1982.
    • (1982) IEEE Transactions on Medical Imaging , vol.MI-1 , pp. 113-122
    • Shepp, L.1    Vardi, Y.2
  • 5
    • 19944427491 scopus 로고    scopus 로고
    • The ClearPET™ project: Development of a 2nd generation high-performance small animal PET scanner
    • K. Ziemons, E. Auffray, R. Barbier et al., "The ClearPET™ project: development of a 2nd generation high-performance small animal PET scanner", Nuclear Instruments and Methods in Physics Research A, 537, 307-311, 2005.
    • (2005) Nuclear Instruments and Methods in Physics Research A , vol.537 , pp. 307-311
    • Ziemons, K.1    Auffray, E.2    Barbier, R.3
  • 6
    • 33846620940 scopus 로고    scopus 로고
    • M. Khodaverdi, S.Weber, M. Streun et al., High Resolution Imaging with ClearPET™Neuro - First Animal Images, in: Proceedings of the IEEE Nuclear Science Symposium & Medical Imaging Conference, 23.-29. Oct. 2005, Wyndham El Conquistador Resort, Puerto Rico.
    • M. Khodaverdi, S.Weber, M. Streun et al., "High Resolution Imaging with ClearPET™Neuro - First Animal Images", in: Proceedings of the IEEE Nuclear Science Symposium & Medical Imaging Conference, 23.-29. Oct. 2005, Wyndham El Conquistador Resort, Puerto Rico.
  • 8
    • 0038282711 scopus 로고    scopus 로고
    • 11C-Raclopride Binding in the Rat Brain Measured with the MicroPET R4: Effects of Scatter Correction and Tracer Specific Activity
    • 11C-Raclopride Binding in the Rat Brain Measured with the MicroPET R4: Effects of Scatter Correction and Tracer Specific Activity", Journal of Nuclear Medicine, 44, 815-822, 2003.
    • (2003) Journal of Nuclear Medicine , vol.44 , pp. 815-822
    • Alexoff, D.L.1    Vaska, P.2    Marsteller, D.3
  • 9
    • 31644440002 scopus 로고    scopus 로고
    • Mean and Covariance Properties of Dynamic PET Reconstructions from List-Mode data
    • E. Asma and R.M. Leahy, "Mean and Covariance Properties of Dynamic PET Reconstructions from List-Mode data", IEEE Transactions on Medical Imaging, 25, 42-54, 2006.
    • (2006) IEEE Transactions on Medical Imaging , vol.25 , pp. 42-54
    • Asma, E.1    Leahy, R.M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.