메뉴 건너뛰기




Volumn 57, Issue 1, 2008, Pages 82-84

Use of a gum elastic bougie for tracheal intubation with Pentax-AWS airway scope

Author keywords

Difficult airway; Laryngoscopes; Tracheal intubation

Indexed keywords

ADULT; ARTICLE; BOUGIE; CASE REPORT; ENDOTRACHEAL INTUBATION; ENDOTRACHEAL TUBE; FEMALE; FIBEROSCOPE; GLOTTIS; HUMAN; LARYNGOSCOPE; RESPIRATORY TRACT DISEASE;

EID: 38549084063     PISSN: 00214892     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (6)

References (9)
  • 2
    • 33846039863 scopus 로고    scopus 로고
    • Asai T, Enomoto Y, Okuda Y. Air Way Scope, a portable videolaryngoscope, for confirmation of tracheal intubation. Resuscitation 2007 ; 72 : 335-6.
    • Asai T, Enomoto Y, Okuda Y. Air Way Scope, a portable videolaryngoscope, for confirmation of tracheal intubation. Resuscitation 2007 ; 72 : 335-6.
  • 3
    • 33846207382 scopus 로고    scopus 로고
    • Airway Scope for difficult intubation
    • Asai T, Enomoto Y, Okuda Y. Airway Scope for difficult intubation. Anaesthesia 2007 ; 62 : 199.
    • (2007) Anaesthesia , vol.62 , pp. 199
    • Asai, T.1    Enomoto, Y.2    Okuda, Y.3
  • 4
    • 38549143387 scopus 로고    scopus 로고
    • Japanese source
    • Japanese source
  • 5
    • 38549084365 scopus 로고    scopus 로고
    • Japanese source
    • Japanese source
  • 6
    • 0031784197 scopus 로고    scopus 로고
    • Tracheal intubation through the intubating laryngeal mask in a patient with a fixed flexed neck and deviated larynx
    • Asai T, Shingu K. Tracheal intubation through the intubating laryngeal mask in a patient with a fixed flexed neck and deviated larynx. Anaesthesia 1998 ; 53 : 1199-208.
    • (1998) Anaesthesia , vol.53 , pp. 1199-1208
    • Asai, T.1    Shingu, K.2
  • 7
    • 0033792019 scopus 로고    scopus 로고
    • Intubating laryngeal mask for fibreoptic intubation - particularly useful during neck stabilization
    • Asai T, Eguchi Y, Murao K, Niitsu T, Shingu K. Intubating laryngeal mask for fibreoptic intubation - particularly useful during neck stabilization. Can J Anaesth 2000 ; 47 : 843-8.
    • (2000) Can J Anaesth , vol.47 , pp. 843-848
    • Asai, T.1    Eguchi, Y.2    Murao, K.3    Niitsu, T.4    Shingu, K.5
  • 8
    • 2942659508 scopus 로고    scopus 로고
    • Difficulty in advancing a tracheal tube over a fibreoptic bronchoscope : Incidence, causes and solutions
    • Asai T, Shingu K. Difficulty in advancing a tracheal tube over a fibreoptic bronchoscope : incidence, causes and solutions. Br J Anaesth 2004 ; 92 : 870-81.
    • (2004) Br J Anaesth , vol.92 , pp. 870-881
    • Asai, T.1    Shingu, K.2
  • 9
    • 0036714817 scopus 로고    scopus 로고
    • Effect of cricoid pressure on the ease of fibrescope-aided tracheal intubation
    • Asai T, Murao K, Johmura S, Shingu K. Effect of cricoid pressure on the ease of fibrescope-aided tracheal intubation. Anaesthesia 2002 ; 57 : 909-13.
    • (2002) Anaesthesia , vol.57 , pp. 909-913
    • Asai, T.1    Murao, K.2    Johmura, S.3    Shingu, K.4