메뉴 건너뛰기




Volumn 81, Issue 961, 2008, Pages 35-45

An investigation into patient and staff doses from X-ray angiography during coronary interventional procedures

Author keywords

[No Author keywords available]

Indexed keywords

ANGIOCARDIOGRAPHY; ARTICLE; CORRELATION COEFFICIENT; FLUOROSCOPY; HUMAN; IONIZATION CHAMBER; MEASUREMENT; PATIENT; PERCUTANEOUS TRANSLUMINAL ANGIOPLASTY; PHANTOM; RADIATION DOSE; RADIATION SCATTERING; WEIGHT; X RAY; X RAY TUBE; CLINICAL TRIAL; HOSPITAL PERSONNEL; IMAGE QUALITY; INSTRUMENTATION; INTERVENTIONAL RADIOLOGY; METHODOLOGY; MULTICENTER STUDY; OCCUPATIONAL EXPOSURE; PROSPECTIVE STUDY; RADIATION PROTECTION; RADIOMETRY; RETROSPECTIVE STUDY; STATISTICS; TRANSLUMINAL CORONARY ANGIOPLASTY;

EID: 38449122052     PISSN: 00071285     EISSN: None     Source Type: Journal    
DOI: 10.1259/bjr/26551424     Document Type: Article
Times cited : (48)

References (23)
  • 1
    • 0141447445 scopus 로고    scopus 로고
    • Efstathopoulos EP, Makrygiannis SS, Kottou S, Karvouni E, Giazitzoglou E, Korovesis S, Tzanalarridou E, Raptou PD, Katritsis DG. Medical personnel and patient dosimetry during coronary angiography and intervention Phys. Med Biol 2003;48:3059-68.
    • Efstathopoulos EP, Makrygiannis SS, Kottou S, Karvouni E, Giazitzoglou E, Korovesis S, Tzanalarridou E, Raptou PD, Katritsis DG. Medical personnel and patient dosimetry during coronary angiography and intervention Phys. Med Biol 2003;48:3059-68.
  • 2
    • 38549175482 scopus 로고    scopus 로고
    • The Ionising Radiations Regulations 1999. SI 3232. London, UK: HMSO; 1999.
    • The Ionising Radiations Regulations 1999. SI 3232. London, UK: HMSO; 1999.
  • 3
    • 38549168758 scopus 로고    scopus 로고
    • Ionising Radiation (Medical Exposure) Regulations. London, UK: HMSO; 2000: SI No.1059.
    • Ionising Radiation (Medical Exposure) Regulations. London, UK: HMSO; 2000: SI No.1059.
  • 6
    • 0037868729 scopus 로고    scopus 로고
    • Radiation exposure of the UK population from medical and dental X-ray examinations. Chilton, UK
    • W4; 2002
    • Hart D, Wall BF. Radiation exposure of the UK population from medical and dental X-ray examinations. Chilton, UK: NRPB Report W4; 2002.
    • NRPB Report
    • Hart, D.1    Wall, B.F.2
  • 7
    • 0028859299 scopus 로고
    • Data analysis on patient exposures in cardiac angiography
    • Huyskens CJ, Hummel WA. Data analysis on patient exposures in cardiac angiography. Radiat Prot Dosim 1995;57:475-80.
    • (1995) Radiat Prot Dosim , vol.57 , pp. 475-480
    • Huyskens, C.J.1    Hummel, W.A.2
  • 10
    • 0030868194 scopus 로고    scopus 로고
    • Radiation exposure to patients undergoing diagnostic and interventional cardiac catheterization procedures
    • Bakalyar DM, Castellani MD, Safian RD. Radiation exposure to patients undergoing diagnostic and interventional cardiac catheterization procedures. Cathet Cardiovasc Diagn 1997;42:121-5.
    • (1997) Cathet Cardiovasc Diagn , vol.42 , pp. 121-125
    • Bakalyar, D.M.1    Castellani, M.D.2    Safian, R.D.3
  • 11
    • 0030983107 scopus 로고    scopus 로고
    • Radiation exposure to patients and operators during diagnostic catheterization and coronary angioplasty
    • Zorzetto M, Bernardi G, Morocutti G, Fontanelli A. Radiation exposure to patients and operators during diagnostic catheterization and coronary angioplasty. Cathet Cardiovasc Diagn 1997;40:348-51.
    • (1997) Cathet Cardiovasc Diagn , vol.40 , pp. 348-351
    • Zorzetto, M.1    Bernardi, G.2    Morocutti, G.3    Fontanelli, A.4
  • 13
    • 0034068506 scopus 로고    scopus 로고
    • Factors affecting patient radiation exposure during routine coronary angiography in a tertiary referral centre
    • Clark AL, Brennan AG, Robertson LJ, McArther JD. Factors affecting patient radiation exposure during routine coronary angiography in a tertiary referral centre. Br J Radiol 2000;73:184-9.
    • (2000) Br J Radiol , vol.73 , pp. 184-189
    • Clark, A.L.1    Brennan, A.G.2    Robertson, L.J.3    McArther, J.D.4
  • 14
    • 0034146244 scopus 로고    scopus 로고
    • Patient radiation exposure during coronary angiography and intervention
    • Fransson S-G, Persliden J. Patient radiation exposure during coronary angiography and intervention. Acta Radiol 2000;41:142-4.
    • (2000) Acta Radiol , vol.41 , pp. 142-144
    • Fransson, S.-G.1    Persliden, J.2
  • 19
    • 0019434272 scopus 로고
    • The tissue-equivalence of the Alderson Rando anthropomorphic phantom for x-rays of diagnostic qualities
    • Shrimpton PC, Wall BF, Fisher ES. The tissue-equivalence of the Alderson Rando anthropomorphic phantom for x-rays of diagnostic qualities. Phys Med Biol 1980;26:133-9.
    • (1980) Phys Med Biol , vol.26 , pp. 133-139
    • Shrimpton, P.C.1    Wall, B.F.2    Fisher, E.S.3
  • 20
    • 0003969654 scopus 로고    scopus 로고
    • Reccommended standards for the routine performance testing of diagnostic x-ray imaging systems
    • Report 77:, York, UK: IPEM;
    • Fitzgerald M, Evans D, Hiles P, Jones A, Payne J, Rigg D, et al. Report 77: Reccommended standards for the routine performance testing of diagnostic x-ray imaging systems. York, UK: IPEM; 1997.
    • (1997)
    • Fitzgerald, M.1    Evans, D.2    Hiles, P.3    Jones, A.4    Payne, J.5    Rigg, D.6
  • 22
    • 2642642152 scopus 로고
    • Estimation of effective dose in diagnostic radiology from entrance surface dose and dose-area product measurements
    • London, UK: HMSO;
    • Hart D, Jones DG, Wall BF. Estimation of effective dose in diagnostic radiology from entrance surface dose and dose-area product measurements. NRPB Report 262. London, UK: HMSO; 1994.
    • (1994) NRPB Report , vol.262
    • Hart, D.1    Jones, D.G.2    Wall, B.F.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.