메뉴 건너뛰기




Volumn 23, Issue 5, 2007, Pages 617-633

A practical guide to reading CT coronary angiograms-How to avoid mistakes when assessing for coronary stenoses

Author keywords

Coronary artery disease; Coronary artery stenosis; Multi detector computed tomography

Indexed keywords

ANGIOCARDIOGRAPHY; COMPUTER ASSISTED TOMOGRAPHY; CORONARY ARTERY CIRCUMFLEX BRANCH; CORONARY ARTERY OBSTRUCTION; DIAGNOSTIC ERROR; HUMAN; IMAGE ANALYSIS; IMAGE QUALITY; IMAGE RECONSTRUCTION; MULTIDETECTOR COMPUTED TOMOGRAPHY; QUANTITATIVE ANALYSIS; REVIEW; ARTIFACT; CALCINOSIS; COMPUTER ASSISTED DIAGNOSIS; DECISION TREE; HOSPITALIZATION; METHODOLOGY; PRACTICE GUIDELINE; PREDICTION AND FORECASTING; RADIOGRAPHY; REPRODUCIBILITY; SENSITIVITY AND SPECIFICITY;

EID: 38449117418     PISSN: 15695794     EISSN: None     Source Type: Journal    
DOI: 10.1007/s10554-006-9173-9     Document Type: Review
Times cited : (31)

References (28)
  • 1
    • 32844462037 scopus 로고    scopus 로고
    • Multidetector computed tomography for the diagnosis of coronary artery disease: A systematic review
    • DOI 10.1016/j.amjmed.2005.06.071, PII S0002934305006571
    • PD Stein A Beemath F Kayali, et al. 2006 Multidetector computed tomography for the diagnosis of coronary artery disease: a systematic review Am J Med 119 203 216 16490463 10.1016/j.amjmed.2005.06.071 (Pubitemid 43255058)
    • (2006) American Journal of Medicine , vol.119 , Issue.3 , pp. 203-216
    • Stein, P.D.1    Beemath, A.2    Kayali, F.3    Skaf, E.4    Sanchez, J.5    Olson, R.E.6
  • 2
    • 33746408724 scopus 로고    scopus 로고
    • Accuracy of 16-row multidetector computed tomography for the assessment of coronary artery stenosis
    • DOI 10.1001/jama.296.4.403
    • MJ Garcia J Lessick MHK Hoffmann 2006 Accuracy of 16-row multidetector computed tomography for the assessment of coronary artery stenosis JAMA 296 403 411 16868298 10.1001/jama.296.4.403 1:CAS:528:DC%2BD28Xntlals74%3D (Pubitemid 44127524)
    • (2006) Journal of the American Medical Association , vol.296 , Issue.4 , pp. 403-411
    • Garcia, M.J.1    Lessick, J.2    Hoffmann, M.H.K.3
  • 4
    • 22844448174 scopus 로고    scopus 로고
    • Diagnostic accuracy of non invasive coronary angiography using 64-slice spiral computed tomography
    • 10.1016/j.jacc.2005.05.056
    • GL Raff MJ Gallager WW O'Neill JA Goldstein 2006 Diagnostic accuracy of non invasive coronary angiography using 64-slice spiral computed tomography J Am Coll Cardiol 46 552 557 10.1016/j.jacc.2005.05.056
    • (2006) J Am Coll Cardiol , vol.46 , pp. 552-557
    • Raff, G.L.1    Gallager, M.J.2    O'Neill, W.W.3    Goldstein, J.A.4
  • 5
    • 33646102670 scopus 로고    scopus 로고
    • Diagnostic accuracy of 64-slice computed tomography fro detecting angiographically significant coronary artery stenosis in an unselected consecutive population: Comparison with conventional invasive angiography
    • 16636491 10.1253/circj.70.564
    • M Ehara JF Surmely M Kawai, et al. 2006 Diagnostic accuracy of 64-slice computed tomography fro detecting angiographically significant coronary artery stenosis in an unselected consecutive population: comparison with conventional invasive angiography Circ J 70 564 571 16636491 10.1253/circj.70.564
    • (2006) Circ J , vol.70 , pp. 564-571
    • Ehara, M.1    Surmely, J.F.2    Kawai, M.3
  • 6
    • 15844420094 scopus 로고    scopus 로고
    • Coronary CT angiography in symptomatic patients
    • CR Becker 2005 Coronary CT angiography in symptomatic patients Eur Radiol l 15 Suppl 2 B33 B41
    • (2005) Eur Radiol L , vol.15 , Issue.SUPPL 2
    • Becker, C.R.1
  • 9
    • 2542596891 scopus 로고    scopus 로고
    • Pitfalls, artifacts and remedies in multi-detector row CT coronary angiography
    • 10.1148/rg.243035502
    • SC Hyun BW Choi KO Choe, et al. 2004 Pitfalls, artifacts and remedies in multi-detector row CT coronary angiography Radiographics 24 787 800 10.1148/rg.243035502
    • (2004) Radiographics , vol.24 , pp. 787-800
    • Hyun, S.C.1    Choi, B.W.2    Choe, K.O.3
  • 10
    • 17444363374 scopus 로고    scopus 로고
    • Pitfalls in 16-detector row CT of the coronary arteries
    • 15798060 10.1148/rg.252045098
    • TN Nakanishi Y Kayashima R Inoue K Sumii Y Gomyo 2005 Pitfalls in 16-detector row CT of the coronary arteries Radiographics 25 425 440 15798060 10.1148/rg.252045098
    • (2005) Radiographics , vol.25 , pp. 425-440
    • Nakanishi, T.N.1    Kayashima, Y.2    Inoue, R.3    Sumii, K.4    Gomyo, Y.5
  • 11
    • 3142537670 scopus 로고    scopus 로고
    • Coronary artery imaging with multidetector CT: Visualisation issues
    • Published online as 10.1148/rg.e16
    • Van Oijen PMA, Ho KY, Dorgelo J, Oudkerk M (2003) Coronary artery imaging with multidetector CT: visualisation issues. Radiographics 23:16e. Published online as 10.1148/rg.e16
    • (2003) Radiographics , vol.23
    • Van Oijen, P.M.A.1    Ho, K.Y.2    Dorgelo, J.3    Oudkerk, M.4
  • 12
    • 29544433145 scopus 로고    scopus 로고
    • Coronary CT angiography: A cardiologist's perspective
    • Achenbach S (2005) Coronary CT angiography: a cardiologist's perspective. Appl Radiol (Supplement):22-23
    • (2005) Appl Radiol , Issue.SUPPL. , pp. 22-23
    • Achenbach, S.1
  • 13
    • 19844381324 scopus 로고    scopus 로고
    • MDCT evaluation of the coronary arteries, 2004: How we do it-data acquisition, postprocessing, display and interpretation
    • 15855087
    • LP Lawler HK Pannu EK Fishman 2005 MDCT evaluation of the coronary arteries, 2004: how we do it-data acquisition, postprocessing, display and interpretation AJR 184 1402 1412 15855087
    • (2005) AJR , vol.184 , pp. 1402-1412
    • Lawler, L.P.1    Pannu, H.K.2    Fishman, E.K.3
  • 17
    • 22144467378 scopus 로고    scopus 로고
    • Influence of intracoronary attenuation on coronary plaque measurements using multislice computed tomography: Observations in an ex vivo model of coronary computed tomography angiography
    • DOI 10.1007/s00330-005-2697-x
    • F Cademartiri NR Mollet G Ruriza, et al. 2005 Influence of intracoronary attenuation on coronary plaque measurements using multislice computed tomography: observations in an ex-vivo model of coronary computed tomography angiography Eur Radiol 15 1426 1431 15750815 10.1007/s00330-005-2697-x (Pubitemid 40983527)
    • (2005) European Radiology , vol.15 , Issue.7 , pp. 1426-1431
    • Cademartiri, F.1    Mollet, N.R.2    Runza, G.3    Bruining, N.4    Hamers, R.5    Somers, P.6    Knaapen, M.7    Verheye, S.8    Midiri, M.9    Krestin, G.P.10    De Feyter, P.J.11
  • 21
    • 0023276691 scopus 로고
    • Compensatory enlargement of human atherosclerotic coronary arteries
    • S Glagov E Wisenberg CK Zarins, et al. 1987 Compensatory enlargement of human atherosclerotic coronary arteries NEJM 316 1371 1375 3574413 1:STN:280:BiiB3c7nvFQ%3D (Pubitemid 17079680)
    • (1987) New England Journal of Medicine , vol.316 , Issue.22 , pp. 1371-1375
    • Glagov, S.1    Weisenberg, E.2    Zarins, C.K.3
  • 24
    • 72649093536 scopus 로고    scopus 로고
    • Diagnostic accuracy of image postprocesing methods for the detection of coronary artery stenoses by multi-detector computed tomography
    • Abstract P1016
    • Achenbach S, Rerencik M, Ropers D et al. (2005) Diagnostic accuracy of image postprocesing methods for the detection of coronary artery stenoses by multi-detector computed tomography. ESC Congress 2005. Abstract P1016
    • (2005) ESC Congress 2005
    • Achenbach, S.1    Rerencik, M.2    Ropers, D.3
  • 25
    • 0347533854 scopus 로고    scopus 로고
    • Optimal contrast application for cardiac 4 detector row computed tomography
    • 14566178 10.1097/01.rli.0000084886.44676.e4
    • CR Becker C Hong A Knez, et al. 2003 Optimal contrast application for cardiac 4 detector row computed tomography Invest Radiol 38 690 694 14566178 10.1097/01.rli.0000084886.44676.e4
    • (2003) Invest Radiol , vol.38 , pp. 690-694
    • Becker, C.R.1    Hong, C.2    Knez, A.3
  • 26
    • 33750106461 scopus 로고    scopus 로고
    • Higher intracoronary attenuation improves diagnostic accuracy in MDCT coronary angiography
    • 16985117 10.2214/AJR.05.1406
    • F Cademartiri NR Mollet P Lemos, et al. 2006 Higher intracoronary attenuation improves diagnostic accuracy in MDCT coronary angiography AJR 187 W430 W433 16985117 10.2214/AJR.05.1406
    • (2006) AJR , vol.187
    • Cademartiri, F.1    Mollet, N.R.2    Lemos, P.3
  • 27
    • 84928096725 scopus 로고    scopus 로고
    • 1 1 The American College of Radiology, with more than 30,000 members, is the principal organization of radiologists, radiation oncologists, and clinical medical physicists in the United States.
    • DOI 10.1016/j.jacr.2006.06.006, PII S154614400600336X
    • JE Jacobs LM Boxt B Desjardins, et al. 2006 ACR practice guideline for the performance & interpretation of cardiac computed tomography J Am Coll Radiol 3 677 685 17412148 10.1016/j.jacr.2006.06.006 (Pubitemid 44419375)
    • (2006) JACR Journal of the American College of Radiology , vol.3 , Issue.9 , pp. 677-685
    • Jacobs, J.E.1    Boxt, L.M.2    Desjardins, B.3    Fishman, E.K.4    Larson, P.A.5    Schoepf, J.6
  • 28
    • 33745685396 scopus 로고    scopus 로고
    • Noncardiac abnormalities in diagnostic cardiac computed tomography: Within normal limits or we never looked!
    • 16843194 10.1016/j.jacc.2006.05.012
    • JA Rumberger 2006 Noncardiac abnormalities in diagnostic cardiac computed tomography: within normal limits or we never looked! J Am Coll Cardiol 48 407 408 16843194 10.1016/j.jacc.2006.05.012
    • (2006) J Am Coll Cardiol , vol.48 , pp. 407-408
    • Rumberger, J.A.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.