메뉴 건너뛰기




Volumn 25, Issue 7, 2007, Pages 335-338

Spasm induced by protection balloon during carotid artery stenting

Author keywords

Carotid stenosis; PercuSurge; Spasm; Stent

Indexed keywords

ADULT; AGED; ARTERY SPASM; ARTICLE; BRAIN ANGIOGRAPHY; CAROTID ARTERIOGRAPHY; CAROTID ARTERY OBSTRUCTION; CONTROLLED STUDY; FEMALE; FOLLOW UP; HUMAN; INTERNAL CAROTID ARTERY; MAJOR CLINICAL STUDY; MALE; PERCUTANEOUS TRANSLUMINAL ANGIOPLASTY; POSTOPERATIVE PERIOD; PROGNOSIS; STENT; BALLOON DILATATION; BRAIN EMBOLISM; BRAIN VASOSPASM; INSTRUMENTATION; RETROSPECTIVE STUDY;

EID: 38449095449     PISSN: 02882043     EISSN: 18625274     Source Type: Journal    
DOI: 10.1007/s11604-007-0148-0     Document Type: Article
Times cited : (8)

References (17)
  • 1
    • 1642575984 scopus 로고    scopus 로고
    • Filter devices for cerebral protection during carotid angioplasty and stenting
    • K Kasirajan PA Schneider KC Kent 2003 Filter devices for cerebral protection during carotid angioplasty and stenting J Endovasc Ther 10 1039 45
    • (2003) J Endovasc Ther , vol.10 , pp. 1039-45
    • Kasirajan, K.1    Schneider, P.A.2    Kent, K.C.3
  • 4
    • 20344393357 scopus 로고    scopus 로고
    • Embolic protection devices for carotid artery stenting: Is there a difference between filter and distal occlusive devices?
    • R Zahn T Ischinger B Mark S Gass U Zeymer W Schmalz 2005 Embolic protection devices for carotid artery stenting: is there a difference between filter and distal occlusive devices? J Am Coll Cardiol 45 1769 74
    • (2005) J Am Coll Cardiol , vol.45 , pp. 1769-74
    • Zahn, R.1    Ischinger, T.2    Mark, B.3    Gass, S.4    Zeymer, U.5    Schmalz, W.6
  • 5
    • 27744547688 scopus 로고    scopus 로고
    • The SPIDER embolic protection device performance evaluation in the carotid artery during percutaneous transluminal angioplasty/and or stenting
    • A Cremonesi 2005 The SPIDER embolic protection device performance evaluation in the carotid artery during percutaneous transluminal angioplasty/and or stenting J Invasive Cardiol 17 463 7
    • (2005) J Invasive Cardiol , vol.17 , pp. 463-7
    • Cremonesi, A.1
  • 6
    • 10744222252 scopus 로고    scopus 로고
    • Routine use of cerebral protection during carotid artery stenting: Results of a multicenter registry of 753 patients
    • B Reimers M Schluter F Castriota T Tübler N Corvaja C Cernetti 2004 Routine use of cerebral protection during carotid artery stenting: results of a multicenter registry of 753 patients Am J Med 116 217 22
    • (2004) Am J Med , vol.116 , pp. 217-22
    • Reimers, B.1    Schluter, M.2    Castriota, F.3    Tübler, T.4    Corvaja, N.5    Cernetti, C.6
  • 9
    • 0036584919 scopus 로고    scopus 로고
    • Protected carotid stenting: Safety and efficacy of the MedNova NeuroShield filter
    • S Macdonald GS Venables TJ Cleveland PA Gaines 2002 Protected carotid stenting: safety and efficacy of the MedNova NeuroShield filter J Vasc Surg 35 966 72
    • (2002) J Vasc Surg , vol.35 , pp. 966-72
    • MacDonald, S.1    Venables, G.S.2    Cleveland, T.J.3    Gaines, P.A.4
  • 10
    • 0346729902 scopus 로고    scopus 로고
    • Critical analysis of distal protection devices
    • T Ohki FJ Veith 2003 Critical analysis of distal protection devices Semin Vasc Surg 16 317 25
    • (2003) Semin Vasc Surg , vol.16 , pp. 317-25
    • Ohki, T.1    Veith, F.J.2
  • 12
    • 6744226372 scopus 로고    scopus 로고
    • Catheter-induced coronary spasm: A view of mechanical factors and experience with selective left coronary arteriography
    • KS Chang KY Wang YW Yao JL Huang WL Lee HY Ho 2000 Catheter-induced coronary spasm: a view of mechanical factors and experience with selective left coronary arteriography Zhonghua Yi Xue Za Zhi (Taipei) 63 107 12
    • (2000) Zhonghua Yi Xue Za Zhi (Taipei) , vol.63 , pp. 107-12
    • Chang, K.S.1    Wang, K.Y.2    Yao, Y.W.3    Huang, J.L.4    Lee, W.L.5    Ho, H.Y.6
  • 14
    • 17644379599 scopus 로고    scopus 로고
    • Vessel wall damage caused by cerebral protection devices: Ex vivo evaluation in porcine carotid arteries
    • S Müller-Hulsbeck P Stolzmann C Liess J Hedderich F Paulsen T Jahnke 2005 Vessel wall damage caused by cerebral protection devices: ex vivo evaluation in porcine carotid arteries Radiology 235 454 60
    • (2005) Radiology , vol.235 , pp. 454-60
    • Müller-Hulsbeck, S.1    Stolzmann, P.2    Liess, C.3    Hedderich, J.4    Paulsen, F.5    Jahnke, T.6
  • 15
    • 0023525782 scopus 로고
    • Angiographic and angioscopic observations of the arterial luminal changes induced by vasospasm
    • Y Uchida F Nakamura T Tomaru H Sonoki S Sumino T Sugimoto 1987 Angiographic and angioscopic observations of the arterial luminal changes induced by vasospasm Am Heart J 114 1096 101
    • (1987) Am Heart J , vol.114 , pp. 1096-101
    • Uchida, Y.1    Nakamura, F.2    Tomaru, T.3    Sonoki, H.4    Sumino, S.5    Sugimoto, T.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.