메뉴 건너뛰기




Volumn 25, Issue 7, 2007, Pages 368-372

Improvement in image quality of noncontrast head images in multidetector-row CT by volume helical scanning with a three-dimensional denoising filter

Author keywords

Denoising filter; Helical scan; Low contrast resolution; Multidetector row CT; Noncontrast head CT

Indexed keywords

ADULT; ARTICLE; CALVARIA; CEREBROVASCULAR ACCIDENT; CLINICAL ARTICLE; CONTROLLED STUDY; FEMALE; HUMAN; IMAGE QUALITY; INTERMETHOD COMPARISON; MALE; MULTIDETECTOR COMPUTED TOMOGRAPHY; NEUROIMAGING; POSTERIOR FOSSA; THREE DIMENSIONAL IMAGING; ANALYSIS OF VARIANCE; ARTIFACT; INSTRUMENTATION; MIDDLE AGED; RADIOGRAPHY; SPIRAL COMPUTER ASSISTED TOMOGRAPHY; STROKE;

EID: 38449095446     PISSN: 02882043     EISSN: 18625274     Source Type: Journal    
DOI: 10.1007/s11604-007-0145-3     Document Type: Article
Times cited : (10)

References (9)
  • 1
    • 0032924568 scopus 로고    scopus 로고
    • Multi-slice helical CT: Scan and reconstruction
    • M Hu 1999 Multi-slice helical CT: scan and reconstruction Med Phys 26 5 18
    • (1999) Med Phys , vol.26 , pp. 5-18
    • Hu, M.1
  • 3
    • 33750116653 scopus 로고    scopus 로고
    • New method of evaluating edge-preserving adaptive filters for computed tomography: Digital phantom method
    • M Okumura T Ota S Tsukagoshi K Katada 2006 New method of evaluating edge-preserving adaptive filters for computed tomography: digital phantom method Nippon Hoshasen Gijutsu Gakkai Zasshi 62 971 8
    • (2006) Nippon Hoshasen Gijutsu Gakkai Zasshi , vol.62 , pp. 971-8
    • Okumura, M.1    Ota, T.2    Tsukagoshi, S.3    Katada, K.4
  • 6
    • 16844376360 scopus 로고    scopus 로고
    • Guidelines for the early management of patients with ischemic stroke: 2005 guideline update
    • H Adams R Adams G Del Zoppo LB Goldstein 2005 Guidelines for the early management of patients with ischemic stroke: 2005 guideline update Stroke 36 916 21
    • (2005) Stroke , vol.36 , pp. 916-21
    • Adams, H.1    Adams, R.2    Del Zoppo, G.3    Goldstein, L.B.4
  • 7
    • 33644856536 scopus 로고    scopus 로고
    • Effect of CT acquisition parameters in the detection of subtle hypoattenuation in acute cerebral infarction: A phantom study
    • C Tanaka T Ueguchi E Shimosegawa N Sasaki T Johkoh H Nakamura 2006 Effect of CT acquisition parameters in the detection of subtle hypoattenuation in acute cerebral infarction: a phantom study AJNR Am J Neuroradiol 27 40 5
    • (2006) AJNR Am J Neuroradiol , vol.27 , pp. 40-5
    • Tanaka, C.1    Ueguchi, T.2    Shimosegawa, E.3    Sasaki, N.4    Johkoh, T.5    Nakamura, H.6
  • 8
    • 0033452893 scopus 로고    scopus 로고
    • The effect of pitch in multislice spiral/helical CT
    • G Wang MW Vannier 1999 The effect of pitch in multislice spiral/helical CT Med Phys 26 2648 53
    • (1999) Med Phys , vol.26 , pp. 2648-53
    • Wang, G.1    Vannier, M.W.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.