메뉴 건너뛰기




Volumn 31, Issue 1, 2004, Pages 67-73

What is happening? Are the current acceptance criteria for therapeutic plasma adequate?

Author keywords

Efficacy; Fresh frozen plasma; Methylene blue; Quality requirement; Safety; Solvent detergent; Transfusion reactions

Indexed keywords

BLOOD CLOTTING FACTOR; DETERGENT; FRESH FROZEN PLASMA; METHYLENE BLUE; PROTEINASE INHIBITOR; RIBOFLAVIN;

EID: 3843070949     PISSN: 14730502     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.transci.2004.04.002     Document Type: Article
Times cited : (6)

References (24)
  • 1
    • 0025893790 scopus 로고
    • Photoinactivation of viruses in human fresh plasma by phenothiazine dyes in combination with visible light
    • Lambrecht B., Mohr H., Knuver-Hopf J., Schmitt H. Photoinactivation of viruses in human fresh plasma by phenothiazine dyes in combination with visible light. Vox Sang. 60:1991;207-213
    • (1991) Vox Sang. , vol.60 , pp. 207-213
    • Lambrecht, B.1    Mohr, H.2    Knuver-Hopf, J.3    Schmitt, H.4
  • 2
    • 0035212881 scopus 로고    scopus 로고
    • The quality of methylene blue light treated FFP and cryoprecipitate
    • Seghatchian J., Krailadsiri P. The quality of methylene blue light treated FFP and cryoprecipitate. Transfus. Apheresis. Sci. 25:2001;227-231
    • (2001) Transfus. Apheresis. Sci. , vol.25 , pp. 227-231
    • Seghatchian, J.1    Krailadsiri, P.2
  • 3
    • 0038692734 scopus 로고    scopus 로고
    • Methylene blue-treated fresh-frozen plasma: What is its contribution to blood safety (review)
    • Williamson L.M., Cardigan R., Prowse C.V. Methylene blue-treated fresh-frozen plasma: what is its contribution to blood safety (review). Transfusion. 43:2003;322-1329
    • (2003) Transfusion , vol.43 , pp. 322-1329
    • Williamson, L.M.1    Cardigan, R.2    Prowse, C.V.3
  • 4
    • 0035209462 scopus 로고    scopus 로고
    • Current strategies for the prevision of safer plasma and its derivatives: An update
    • Seghatchian J., Allain J.P. Current strategies for the prevision of safer plasma and its derivatives: an update. Transfu. Apheres. Sci. 25:2001;185-187
    • (2001) Transfu. Apheres. Sci. , vol.25 , pp. 185-187
    • Seghatchian, J.1    Allain, J.P.2
  • 6
    • 0036144173 scopus 로고    scopus 로고
    • Virus inactivation in blood components by photoactive phenothiazine dyes
    • Wagner S.J. Virus inactivation in blood components by photoactive phenothiazine dyes. Transfus. Med. Rev. 16:2002;61-66
    • (2002) Transfus. Med. Rev. , vol.16 , pp. 61-66
    • Wagner, S.J.1
  • 7
    • 0035176632 scopus 로고    scopus 로고
    • Residual red cell and platelet contents in WBC-reduced plasma measured by a novel flowcytometric method
    • Krailadsiri P., Seghatchian J. Residual red cell and platelet contents in WBC-reduced plasma measured by a novel flowcytometric method. Transfus. Apheres. Sci. 24:2001;270-286
    • (2001) Transfus. Apheres. Sci. , vol.24 , pp. 270-286
    • Krailadsiri, P.1    Seghatchian, J.2
  • 8
    • 0041662147 scopus 로고    scopus 로고
    • Universal leucodepletion: An overview of some unreserved issues and the highlights of lessons learned
    • Seghatchian J. Universal leucodepletion: an overview of some unreserved issues and the highlights of lessons learned. Transfus. Apheres. Sci. 29:2003;105-117
    • (2003) Transfus. Apheres. Sci. , vol.29 , pp. 105-117
    • Seghatchian, J.1
  • 9
    • 0242440046 scopus 로고    scopus 로고
    • Residual cell content in plasma produced by three centrifugal apheresis procedures
    • Burnouf T., Kappelsberger C., Frank K., Burkhardt T. Residual cell content in plasma produced by three centrifugal apheresis procedures. Transfusion. 43:2003;1522-1526
    • (2003) Transfusion , vol.43 , pp. 1522-1526
    • Burnouf, T.1    Kappelsberger, C.2    Frank, K.3    Burkhardt, T.4
  • 10
  • 12
    • 0034785795 scopus 로고    scopus 로고
    • Role of methylene blue-treated or fresh plasma in the response to plasma exchange in patients with thrombotic thrombocytopenic purpura
    • De la Rubia J., Arriaga F., Linares D. Role of methylene blue-treated or fresh plasma in the response to plasma exchange in patients with thrombotic thrombocytopenic purpura. Br. J. Haematol. 114:2001;721-723
    • (2001) Br. J. Haematol. , vol.114 , pp. 721-723
    • De La Rubia, J.1    Arriaga, F.2    Linares, D.3
  • 13
    • 0030813516 scopus 로고    scopus 로고
    • The quality of clinical FFP, cryoprecipitate, cryosupernatant-derived from single donor apheresis procedures and random donations collected in BAT system: Assessment of the quality states of FVIII, contact activation, microvesicle content and cytokines
    • Seghatchian J. The quality of clinical FFP, cryoprecipitate, cryosupernatant-derived from single donor apheresis procedures and random donations collected in BAT system: assessment of the quality states of FVIII, contact activation, microvesicle content and cytokines. Transfus. Sci. 18:1997;115-118
    • (1997) Transfus. Sci. , vol.18 , pp. 115-118
    • Seghatchian, J.1
  • 14
    • 0037206603 scopus 로고    scopus 로고
    • Manufacture and composition of fresh frozen plasma and virus inactivated therapeutic plasma preparations: Correlations between composition and therapeutic efficacy
    • Hellstem P., Haubelt H. Manufacture and composition of fresh frozen plasma and virus inactivated therapeutic plasma preparations: correlations between composition and therapeutic efficacy. Thromb. Res. 107:2002;83-88
    • (2002) Thromb. Res. , vol.107 , pp. 83-88
    • Hellstem, P.1    Haubelt, H.2
  • 15
    • 0037206596 scopus 로고    scopus 로고
    • Quality of therapeutic plasma: Requirements for marketing authorization
    • Heiden M., Seitez R. Quality of therapeutic plasma: requirements for marketing authorization. Thromb. Res. 107:2002;47-51
    • (2002) Thromb. Res. , vol.107 , pp. 47-51
    • Heiden, M.1    Seitez, R.2
  • 16
    • 0043165035 scopus 로고    scopus 로고
    • Non-viral, non-hemolytic adverse effects of transfusion
    • Sazama K. Non-viral, non-hemolytic adverse effects of transfusion. Transfus. Apheresis. Sci. 29:2003;131-132
    • (2003) Transfus. Apheresis. Sci. , vol.29 , pp. 131-132
    • Sazama, K.1
  • 17
    • 0033381628 scopus 로고    scopus 로고
    • Clinical tolerance of methylene blue virus-inactivated plasma
    • Simonson A.C., Sorensen H. Clinical tolerance of methylene blue virus-inactivated plasma. Vox Sang. 77:1999;210-217
    • (1999) Vox Sang. , vol.77 , pp. 210-217
    • Simonson, A.C.1    Sorensen, H.2
  • 19
    • 0010692251 scopus 로고    scopus 로고
    • Prospective, randomised and controlled study on solvent /detergent versus methylene blue light virus-inactivated plasma
    • Wieding J.U., Rathgeber J., Zemker D., Pohl U., Kohler M. Prospective, randomised and controlled study on solvent /detergent versus methylene blue light virus-inactivated plasma. Transfusion. (SV):1999;23
    • (1999) Transfusion , Issue.SV , pp. 23
    • Wieding, J.U.1    Rathgeber, J.2    Zemker, D.3    Pohl, U.4    Kohler, M.5
  • 20
    • 0842281643 scopus 로고    scopus 로고
    • Mammalian prion biology: One century of evolving concepts
    • Aguzzi A., Polymenidou M. Mammalian prion biology: one century of evolving concepts. Cell. 16:2004;313-327
    • (2004) Cell , vol.16 , pp. 313-327
    • Aguzzi, A.1    Polymenidou, M.2
  • 21
    • 0041662142 scopus 로고    scopus 로고
    • Apoptosis, TGF-beta and transfusion-related immunosuppression: Biological versus clinical effects
    • Dzik W.H. Apoptosis, TGF-beta and transfusion-related immunosuppression: biological versus clinical effects. Transfus. Apheres. Sci. 29:2003;127-129
    • (2003) Transfus. Apheres. Sci. , vol.29 , pp. 127-129
    • Dzik, W.H.1
  • 22
    • 0043165039 scopus 로고    scopus 로고
    • A novel method for the assessment of pro- and anti-coagulant properties of platelet-derived microvesicle and its usefulness for quality of platelet haemostatic function
    • Seghatchian J. A novel method for the assessment of pro- and anti-coagulant properties of platelet-derived microvesicle and its usefulness for quality of platelet haemostatic function. Transfus. Apheres. Sci. 20:2003;119-125
    • (2003) Transfus. Apheres. Sci. , vol.20 , pp. 119-125
    • Seghatchian, J.1
  • 23
    • 85058724160 scopus 로고    scopus 로고
    • Blood cell apoptosis/necrosis: Some laboratory and clinical aspects
    • Seghatchia J., De Sousa G. Blood cell apoptosis/necrosis: some laboratory and clinical aspects. Ann NO Y Sci. 1010:2003;S40-S47
    • (2003) Ann NO Y Sci , vol.1010
    • Seghatchia, J.1    De Sousa, G.2
  • 24
    • 3843115835 scopus 로고    scopus 로고
    • The influence of methylene blue light treatment and methylene blue removal filter on fibrinogen activity states and fibrin polymerisation indices
    • submitted
    • Depasse F, Seghatchian J, Sensebe L, Andreu G, Samama MM. The influence of methylene blue light treatment and methylene blue removal filter on fibrinogen activity states and fibrin polymerisation indices. Transfusion 2004; submitted
    • (2004) Transfusion
    • Depasse, F.1    Seghatchian, J.2    Sensebe, L.3    Andreu, G.4    Samama, M.M.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.