1
-
-
0031963386
-
Determination of cadmium in mussels by flame atomic absorption spectrometry with preconcentration on a chelating resin in a flow injection system
-
M F Enríquez-Domínquez M C Yebra-Biurrun M P Bermejo-Barrera 1998 Determination of cadmium in mussels by flame atomic absorption spectrometry with preconcentration on a chelating resin in a flow injection system Analyst 123 105
-
(1998)
Analyst
, vol.123
, pp. 105
-
-
Enríquez-Domínquez, M.F.1
Yebra-Biurrun, M.C.2
Bermejo-Barrera, M.P.3
-
2
-
-
0037783999
-
Experimental designs in the development of a new method for the sensitive determination of cadmium in seawater by adsorptive cathodic stripping voltammetry
-
J A Jurado-González M D Galindo-Riaño M García-Vargas 2003 Experimental designs in the development of a new method for the sensitive determination of cadmium in seawater by adsorptive cathodic stripping voltammetry Anal Chim Acta 487 229
-
(2003)
Anal Chim Acta
, vol.487
, pp. 229
-
-
Jurado-González, J.A.1
Galindo-Riaño, M.D.2
García-Vargas, M.3
-
3
-
-
4544371759
-
Minicolumn field preconcentration and flow-injection flame atomic absorption spectrometry determination of cadmium in seawater
-
M C Yebra-Biurrun A Moreno-Cid L Puig 2004 Minicolumn field preconcentration and flow-injection flame atomic absorption spectrometry determination of cadmium in seawater Anal Chim Acta 524 73
-
(2004)
Anal Chim Acta
, vol.524
, pp. 73
-
-
Yebra-Biurrun, M.C.1
Moreno-Cid, A.2
Puig, L.3
-
4
-
-
0042583718
-
Low blank preconcentration technique for the determination of lead, copper, and cadmium in small-volume seawater samples by isotope dilution ICP-MS
-
J F Wu E A Boyle 1997 Low blank preconcentration technique for the determination of lead, copper, and cadmium in small-volume seawater samples by isotope dilution ICP-MS Anal Chem 69 2464
-
(1997)
Anal Chem
, vol.69
, pp. 2464
-
-
Wu, J.F.1
Boyle, E.A.2
-
5
-
-
24144482784
-
Amberlite XAD-2 functionalized with 2-aminothiophenol as a new sorbent for on-line preconcentration of cadmium and copper
-
V A Lemos P X Baliza 2005 Amberlite XAD-2 functionalized with 2-aminothiophenol as a new sorbent for on-line preconcentration of cadmium and copper Talanta 67 564
-
(2005)
Talanta
, vol.67
, pp. 564
-
-
Lemos, V.A.1
Baliza, P.X.2
-
6
-
-
17144434595
-
Preconcentration and flame atomic absorption spectrometry determination of cadmium in mussels by an on-line continuous precipitation-dissolution flow system
-
M C Yebra M F Enriquez R M Cespon 2000 Preconcentration and flame atomic absorption spectrometry determination of cadmium in mussels by an on-line continuous precipitation-dissolution flow system Talanta 52 631
-
(2000)
Talanta
, vol.52
, pp. 631
-
-
Yebra, M.C.1
Enriquez, M.F.2
Cespon, R.M.3
-
7
-
-
33646436439
-
Sequential/bead injection lab-on-valve incorporating a renewable microcolumn for co-precipitate preconcentration of cadmium coupled to hydride generation atomic fluorescence spectrometry
-
Y Wang M L Chen J H Wang 2006 Sequential/bead injection lab-on-valve incorporating a renewable microcolumn for co-precipitate preconcentration of cadmium coupled to hydride generation atomic fluorescence spectrometry J Anal At Spectrom 21 535
-
(2006)
J Anal at Spectrom
, vol.21
, pp. 535
-
-
Wang, Y.1
Chen, M.L.2
Wang, J.H.3
-
8
-
-
0344099107
-
Development of an on-line solvent extraction system for electrothermal atomic absorption spectrometry utilizing a new gravitational phase separator. Determination of cadmium in natural waters and urine samples
-
A N Anthemidis G A Zachariadis J A Stratis 2003 Development of an on-line solvent extraction system for electrothermal atomic absorption spectrometry utilizing a new gravitational phase separator. Determination of cadmium in natural waters and urine samples J Anal At Spectrom 18 1400
-
(2003)
J Anal at Spectrom
, vol.18
, pp. 1400
-
-
Anthemidis, A.N.1
Zachariadis, G.A.2
Stratis, J.A.3
-
9
-
-
15444373842
-
An ion-imprinted functionalized silica gel sorbent prepared by a surface imprinting technique combined with a sol-gel process for selective solid-phase extraction of cadmium(II)
-
G Z Fang J Tan X P Yan 2005 An ion-imprinted functionalized silica gel sorbent prepared by a surface imprinting technique combined with a sol-gel process for selective solid-phase extraction of cadmium(II) Anal Chem 77 1734
-
(2005)
Anal Chem
, vol.77
, pp. 1734
-
-
Fang, G.Z.1
Tan, J.2
Yan, X.P.3
-
11
-
-
0037228679
-
On-line preconcentration/determination of cadmium in drinking water on activated carbon using 8-hydroxyquinoline in a flow injection system coupled to an inductively coupled plasma optical emission spectrometer
-
S Cerutti M F Silva J A Gasquez R A Olsina L D Martinez 2003 On-line preconcentration/determination of cadmium in drinking water on activated carbon using 8-hydroxyquinoline in a flow injection system coupled to an inductively coupled plasma optical emission spectrometer Spectrochim Acta Part B 58 43
-
(2003)
Spectrochim Acta Part B
, vol.58
, pp. 43
-
-
Cerutti, S.1
Silva, M.F.2
Gasquez, J.A.3
Olsina, R.A.4
Martinez, L.D.5
-
12
-
-
0036019784
-
Development of a method for the determination of inorganic cadmium and cadmium metallothioneins in fish liver by continuous preconcentration on fullerene and flame atomic absorption spectrometry
-
J Munoz J R Baena M Gallego M Valcarcel 2002 Development of a method for the determination of inorganic cadmium and cadmium metallothioneins in fish liver by continuous preconcentration on fullerene and flame atomic absorption spectrometry J Anal At Spectrom 17 716
-
(2002)
J Anal at Spectrom
, vol.17
, pp. 716
-
-
Munoz, J.1
Baena, J.R.2
Gallego, M.3
Valcarcel, M.4
-
13
-
-
0037325314
-
Exploiting the bead-injection approach in the integrated sequential injection lab-on-valve format using hydrophobic packing materials for on-line matrix removal and preconcentration of trace levels of cadmium in environmental and biological samples via formation of non-charged chelates prior to ETAAS detection
-
M Miró S Jończyk J H Wang E H Hansen 2003 Exploiting the bead-injection approach in the integrated sequential injection lab-on-valve format using hydrophobic packing materials for on-line matrix removal and preconcentration of trace levels of cadmium in environmental and biological samples via formation of non-charged chelates prior to ETAAS detection J Anal At Spectrom 18 89
-
(2003)
J Anal at Spectrom
, vol.18
, pp. 89
-
-
Miró, M.1
Jończyk, S.2
Wang, J.H.3
Hansen, E.H.4
-
14
-
-
0034777793
-
Flow injection on-line preconcentration and separation coupled with atomic(mass) spectrometry for trace element (speciation) analysis based on sorption of organo-metallic complexes in a knotted reactor
-
X P Yan Y Jiang 2001 Flow injection on-line preconcentration and separation coupled with atomic(mass) spectrometry for trace element (speciation) analysis based on sorption of organo-metallic complexes in a knotted reactor Trends Anal Chem 20 552
-
(2001)
Trends Anal Chem
, vol.20
, pp. 552
-
-
Yan, X.P.1
Jiang, Y.2
-
15
-
-
0028254322
-
Determination of cadmium in biological materials by flame atomic absorption spectrometry with flow-injection on-line sorption preconcentration
-
Z L Fang S K Xu L P Dong W Q Li 1994 Determination of cadmium in biological materials by flame atomic absorption spectrometry with flow-injection on-line sorption preconcentration Talanta 41 2165
-
(1994)
Talanta
, vol.41
, pp. 2165
-
-
Fang, Z.L.1
Xu, S.K.2
Dong, L.P.3
Li, W.Q.4
-
16
-
-
0037427255
-
Determination of trace cadmium in rice by flow injection on-line filterless precipitation-dissolution preconcentration coupled with flame atomic absorption spectrometry
-
Q Y Ye Y Li Y Jiang X P Yan 2003 Determination of trace cadmium in rice by flow injection on-line filterless precipitation-dissolution preconcentration coupled with flame atomic absorption spectrometry J Agric Food Chem 51 2111
-
(2003)
J Agric Food Chem
, vol.51
, pp. 2111
-
-
Ye, Q.Y.1
Li, Y.2
Jiang, Y.3
Yan, X.P.4
-
17
-
-
4043092735
-
Optimization of the preconcentration system of cadmium with 1(2-thiazolylazo)-p-cresol using a knotted reactor and flame atomic absorption spectrometric detection
-
S Cerutti S L C Ferreira J A Gásquez R A Olsina L D Martinez 2004 Optimization of the preconcentration system of cadmium with 1(2-thiazolylazo)-p- cresol using a knotted reactor and flame atomic absorption spectrometric detection J Hazard Mater 112 279
-
(2004)
J Hazard Mater
, vol.112
, pp. 279
-
-
Cerutti, S.1
Ferreira, S.L.C.2
Gásquez, J.A.3
Olsina, R.A.4
Martinez, L.D.5
-
18
-
-
19744367122
-
Application of Box-Behnken design in the optimisation of an on-line pre-concentration system using knotted reactor for cadmium determination by flame atomic absorption spectrometry
-
A S Souza W N L dos Santos S L C Ferreira 2005 Application of Box-Behnken design in the optimisation of an on-line pre-concentration system using knotted reactor for cadmium determination by flame atomic absorption spectrometry Spectrochim Acta Part B 60 737
-
(2005)
Spectrochim Acta Part B
, vol.60
, pp. 737
-
-
Souza, A.S.1
Dos Santos, W.N.L.2
Ferreira, S.L.C.3
-
19
-
-
0032490399
-
Electrothermal atomic absorption spectrometric determination of cadmium and lead in blood using flow injection on-line sorption preconcentration in a knotted reactor
-
E Ivanova W Van Mol F Adams 1998 Electrothermal atomic absorption spectrometric determination of cadmium and lead in blood using flow injection on-line sorption preconcentration in a knotted reactor Spectrochim Acta Part B 53 1041
-
(1998)
Spectrochim Acta Part B
, vol.53
, pp. 1041
-
-
Ivanova, E.1
Van Mol, W.2
Adams, F.3
-
20
-
-
0032673492
-
Flow injection on-line sorption preconcentration of trace amounts of copper and manganese in a knotted reactor precoated with 1-phenyl-3-methyl-4- benzoylpyrazol-5-one coupled with electrothermal atomic absorption spectrometry
-
I Benkhedda E Ivanova F Adams 1999 Flow injection on-line sorption preconcentration of trace amounts of copper and manganese in a knotted reactor precoated with 1-phenyl-3-methyl-4-benzoylpyrazol-5-one coupled with electrothermal atomic absorption spectrometry J Anal At Spectrom 14 957
-
(1999)
J Anal at Spectrom
, vol.14
, pp. 957
-
-
Benkhedda, I.1
Ivanova, E.2
Adams, F.3
-
21
-
-
0035543183
-
Determination of low cadmium concentrations in wine by on-line preconcentration in a knotted reactor coupled to an inductively coupled plasma optical emission spectrometer with ultrasonic nebulization
-
R F Lara R G Wuilloud J A Salonia R A Olsina L D Martinez 2001 Determination of low cadmium concentrations in wine by on-line preconcentration in a knotted reactor coupled to an inductively coupled plasma optical emission spectrometer with ultrasonic nebulization Fresenius' J Anal Chem 371 989
-
(2001)
Fresenius' J Anal Chem
, vol.371
, pp. 989
-
-
Lara, R.F.1
Wuilloud, R.G.2
Salonia, J.A.3
Olsina, R.A.4
Martinez, L.D.5
-
22
-
-
0034299561
-
Trace metal analysis of natural waters and biological samples by axial inductively coupled plasma time of flight mass spectrometry (ICP-TOFMS) with flow injection on-line adsorption preconcentration using a knotted reactor
-
K Benkhedda H G Infante E Ivanova F C Adams 2000 Trace metal analysis of natural waters and biological samples by axial inductively coupled plasma time of flight mass spectrometry (ICP-TOFMS) with flow injection on-line adsorption preconcentration using a knotted reactor J Anal At Spectrom 15 1349
-
(2000)
J Anal at Spectrom
, vol.15
, pp. 1349
-
-
Benkhedda, K.1
Infante, H.G.2
Ivanova, E.3
Adams, F.C.4
-
23
-
-
17444431556
-
Determination of cadmium by flow injection atomic absorption spectrometry with cold vapor generation by a tetrahydroborate-form anion-exchanger
-
W Chuachuad J F Tyson 2005 Determination of cadmium by flow injection atomic absorption spectrometry with cold vapor generation by a tetrahydroborate-form anion-exchanger J Anal At Spectrom 20 273
-
(2005)
J Anal at Spectrom
, vol.20
, pp. 273
-
-
Chuachuad, W.1
Tyson, J.F.2
-
24
-
-
4344607822
-
Chemical vapor generation by reaction of cadmium with potassium tetrahydroborate and sodium iodate in acidic aqueous solution for atomic fluorescence spectrometric application
-
G Li L Wu J J Xin X G Hou 2004 Chemical vapor generation by reaction of cadmium with potassium tetrahydroborate and sodium iodate in acidic aqueous solution for atomic fluorescence spectrometric application J Anal At Spectrom 19 1010
-
(2004)
J Anal at Spectrom
, vol.19
, pp. 1010
-
-
Li, G.1
Wu, L.2
Xin, J.J.3
Hou, X.G.4
-
25
-
-
1542404595
-
Enhancement reagents for simultaneous vapor generation of zinc and cadmium with intermittent flow system coupled to atomic fluorescence spectrometry
-
H W Sun R Suo 2004 Enhancement reagents for simultaneous vapor generation of zinc and cadmium with intermittent flow system coupled to atomic fluorescence spectrometry Anal Chim Acta 509 71
-
(2004)
Anal Chim Acta
, vol.509
, pp. 71
-
-
Sun, H.W.1
Suo, R.2
-
26
-
-
27144488281
-
Preliminary results on the determination of ultratrace amounts of cadmium in tea samples using a flow injection on-line solid phase extraction separation and preconcentration technique to couple with a sequential injection hydride generation atomic fluorescence spectrometry
-
T C Duan X J Song D Jin H F Li J W Xu H T Chen 2005 Preliminary results on the determination of ultratrace amounts of cadmium in tea samples using a flow injection on-line solid phase extraction separation and preconcentration technique to couple with a sequential injection hydride generation atomic fluorescence spectrometry Talanta 67 968
-
(2005)
Talanta
, vol.67
, pp. 968
-
-
Duan, T.C.1
Song, X.J.2
Jin, D.3
Li, H.F.4
Xu, J.W.5
Chen, H.T.6
-
27
-
-
3242816142
-
Simultaneous determination of trace mercury and cadmium in tobacco samples by cold vapor generation-atomic fluorescence spectrometry
-
W E Gan W W Shi Q D Su 2004 Simultaneous determination of trace mercury and cadmium in tobacco samples by cold vapor generation-atomic fluorescence spectrometry J Anal At Spectrom 19 911
-
(2004)
J Anal at Spectrom
, vol.19
, pp. 911
-
-
Gan, W.E.1
Shi, W.W.2
Su, Q.D.3
-
28
-
-
0042315135
-
Simultaneous determination of trace cadmium and mercury in Chinese herbal medicine by non-dispersive atomic fluorescence spectrometry using intermittent flow vapor generator
-
H W Sun R Suo Y K Lu 2003 Simultaneous determination of trace cadmium and mercury in Chinese herbal medicine by non-dispersive atomic fluorescence spectrometry using intermittent flow vapor generator Anal Sci 19 1045
-
(2003)
Anal Sci
, vol.19
, pp. 1045
-
-
Sun, H.W.1
Suo, R.2
Lu, Y.K.3
-
29
-
-
0036534518
-
Simultaneous determination of trace cadmium and arsenic in biological samples by hydride generation-double channel atomic fluorescence spectrometry
-
Y K Lu H W Sun C G Yuan X P Yan 2002 Simultaneous determination of trace cadmium and arsenic in biological samples by hydride generation-double channel atomic fluorescence spectrometry Anal Chem 74 1525
-
(2002)
Anal Chem
, vol.74
, pp. 1525
-
-
Lu, Y.K.1
Sun, H.W.2
Yuan, C.G.3
Yan, X.P.4
-
30
-
-
33747075103
-
Non-chromatographic speciation analysis of mercury by flow injection on-line preconcentration in combination with chemical vapor generation atomic fluorescence spectrometry
-
H Wu Y Jin W Y Han Q Miao S P Bi 2006 Non-chromatographic speciation analysis of mercury by flow injection on-line preconcentration in combination with chemical vapor generation atomic fluorescence spectrometry Spectrochim Acta Part B 61 831
-
(2006)
Spectrochim Acta Part B
, vol.61
, pp. 831
-
-
Wu, H.1
Jin, Y.2
Han, W.Y.3
Miao, Q.4
Bi, S.P.5
-
31
-
-
33847098706
-
On-line organoselenium interference removal for inorganic selenium species by flow injection coprecipitation preconcentration coupled with hydride generation atomic fluorescence spectrometry
-
H Wu Y Jin Y Q Shi S P Bi 2007 On-line organoselenium interference removal for inorganic selenium species by flow injection coprecipitation preconcentration coupled with hydride generation atomic fluorescence spectrometry Talanta 71 1762
-
(2007)
Talanta
, vol.71
, pp. 1762
-
-
Wu, H.1
Jin, Y.2
Shi, Y.Q.3
Bi, S.P.4
-
32
-
-
0342733678
-
Ultratrace determination of cobalt in natural waters by electrothermal atomic absorption spectrometry using flow-injection on-line sorption preconcentration in a knotted reactor precoated with 1-phenyl-3-methyl- benzoylpyrazol-5-one
-
K Benkhedda H G Infante E Ivanova F Adams 2000 Ultratrace determination of cobalt in natural waters by electrothermal atomic absorption spectrometry using flow-injection on-line sorption preconcentration in a knotted reactor precoated with 1-phenyl-3-methyl-benzoylpyrazol-5-one J Anal At Spectrom 15 429
-
(2000)
J Anal at Spectrom
, vol.15
, pp. 429
-
-
Benkhedda, K.1
Infante, H.G.2
Ivanova, E.3
Adams, F.4
|