메뉴 건너뛰기




Volumn 61, Issue 2, 2008, Pages 124-129

Augmentation mammoplasty: effect on diagnosis of breast cancer

Author keywords

Breast augmentation; Breast cancer; Breast imaging; Tissue diagnosis

Indexed keywords

BREAST AUGMENTATION; BREAST CANCER; BREAST ENDOPROSTHESIS; CANCER DIAGNOSIS; HISTORY; HUMAN; MAMMOGRAPHY; MEDICAL LITERATURE; PRIORITY JOURNAL; RADIOLOGY; REVIEW;

EID: 38349075240     PISSN: 17486815     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.bjps.2007.06.035     Document Type: Review
Times cited : (27)

References (60)
  • 1
    • 38349036700 scopus 로고    scopus 로고
    • American Society of Plastic Surgeons (2006). http://www.plasticsurgery.org/news_room/Procedural-Statistics-Press-Kit-Index.cfm9-1-2005
    • (2006)
    • American Society of Plastic Surgeons1
  • 2
    • 0028920691 scopus 로고
    • The prevalence of women with breast implants in the United States, 1989
    • Cook R.R., Delongchamp R.R., Woodbury M., et al. The prevalence of women with breast implants in the United States, 1989. J Clin Epidemiol 48 (1995) 519-525
    • (1995) J Clin Epidemiol , vol.48 , pp. 519-525
    • Cook, R.R.1    Delongchamp, R.R.2    Woodbury, M.3
  • 3
    • 0035037999 scopus 로고    scopus 로고
    • Breast implants and cancer: causation, delayed detection, and survival
    • Hoshaw S.J., Klein P.J., Clark B.D., et al. Breast implants and cancer: causation, delayed detection, and survival. Plast Reconstr Surg 107 (2001) 1393-1407
    • (2001) Plast Reconstr Surg , vol.107 , pp. 1393-1407
    • Hoshaw, S.J.1    Klein, P.J.2    Clark, B.D.3
  • 4
    • 0016194513 scopus 로고
    • Effect of augmentation mammaplasty on mammography and thermography
    • Rintala A.E., and Svinhufvud U.M. Effect of augmentation mammaplasty on mammography and thermography. Plast Reconstr Surg 54 (1974) 390-396
    • (1974) Plast Reconstr Surg , vol.54 , pp. 390-396
    • Rintala, A.E.1    Svinhufvud, U.M.2
  • 5
    • 0017611442 scopus 로고
    • Xeromammography: a reason for using saline-filled breast prostheses
    • Cohen I.K., Goodman H., and Theogaraj S.D. Xeromammography: a reason for using saline-filled breast prostheses. Plast Reconstr Surg 60 (1977) 886-888
    • (1977) Plast Reconstr Surg , vol.60 , pp. 886-888
    • Cohen, I.K.1    Goodman, H.2    Theogaraj, S.D.3
  • 6
    • 0018001515 scopus 로고
    • On mammography in the presence of breast implants
    • Wolfe J.N. On mammography in the presence of breast implants. Plast Reconstr Surg 62 (1978) 286-288
    • (1978) Plast Reconstr Surg , vol.62 , pp. 286-288
    • Wolfe, J.N.1
  • 7
    • 0022000378 scopus 로고
    • Xeromammography after augmentation mammoplasty
    • Jensen S.R., and Mackey J.K. Xeromammography after augmentation mammoplasty. AJR Am J Roentgenol 144 (1985) 629-633
    • (1985) AJR Am J Roentgenol , vol.144 , pp. 629-633
    • Jensen, S.R.1    Mackey, J.K.2
  • 9
    • 0024853735 scopus 로고
    • The effect of breast implants on the radiographic detection of microcalcification and soft-tissue masses
    • Gumucio C.A., Pin P., Young V.L., et al. The effect of breast implants on the radiographic detection of microcalcification and soft-tissue masses. Plast Reconstr Surg 84 (1989) 772-778
    • (1989) Plast Reconstr Surg , vol.84 , pp. 772-778
    • Gumucio, C.A.1    Pin, P.2    Young, V.L.3
  • 10
    • 0018097554 scopus 로고
    • Irregularity of Silastic breast implants mimicking a soft tissue mass
    • Grant E.G., Cigtay O.S., and Mascatello V.J. Irregularity of Silastic breast implants mimicking a soft tissue mass. AJR Am J Roentgenol 130 (1978) 461-462
    • (1978) AJR Am J Roentgenol , vol.130 , pp. 461-462
    • Grant, E.G.1    Cigtay, O.S.2    Mascatello, V.J.3
  • 12
    • 0025602909 scopus 로고
    • Mammographic measurements before and after augmentation mammaplasty
    • Silverstein M.J., Handel N., Gamagami P., et al. Mammographic measurements before and after augmentation mammaplasty. Plast Reconstr Surg 86 (1990) 1126-1130
    • (1990) Plast Reconstr Surg , vol.86 , pp. 1126-1130
    • Silverstein, M.J.1    Handel, N.2    Gamagami, P.3
  • 13
    • 0026529947 scopus 로고
    • Breast cancer diagnosis and prognosis in women following augmentation with silicone gel-filled prostheses
    • Silverstein M.J., Handel N., Gamagami P., et al. Breast cancer diagnosis and prognosis in women following augmentation with silicone gel-filled prostheses. Eur J Cancer 28 (1992) 635-640
    • (1992) Eur J Cancer , vol.28 , pp. 635-640
    • Silverstein, M.J.1    Handel, N.2    Gamagami, P.3
  • 14
    • 9144273732 scopus 로고    scopus 로고
    • Effect of breast augmentation on the accuracy of mammography and cancer characteristics
    • Miglioretti D.L., Rutter C.M., Geller B.M., et al. Effect of breast augmentation on the accuracy of mammography and cancer characteristics. JAMA 291 (2004) 442-450
    • (2004) JAMA , vol.291 , pp. 442-450
    • Miglioretti, D.L.1    Rutter, C.M.2    Geller, B.M.3
  • 15
    • 0036166079 scopus 로고    scopus 로고
    • The silicone gel-filled breast implant controversy: an update
    • Muzaffar A.R., and Rohrich R.J. The silicone gel-filled breast implant controversy: an update. Plast Reconstr Surg 109 (2002) 742-747
    • (2002) Plast Reconstr Surg , vol.109 , pp. 742-747
    • Muzaffar, A.R.1    Rohrich, R.J.2
  • 16
    • 0029902170 scopus 로고    scopus 로고
    • Effect of age, breast density, and family history on the sensitivity of first screening mammography
    • Kerlikowske K., Grady D., Barclay J., et al. Effect of age, breast density, and family history on the sensitivity of first screening mammography. JAMA 276 (1996) 33-38
    • (1996) JAMA , vol.276 , pp. 33-38
    • Kerlikowske, K.1    Grady, D.2    Barclay, J.3
  • 17
    • 0034610318 scopus 로고    scopus 로고
    • Performance of screening mammography among women with and without a first-degree relative with breast cancer
    • Kerlikowske K., Carney P.A., Geller B., et al. Performance of screening mammography among women with and without a first-degree relative with breast cancer. Ann Intern Med 133 (2000) 855-863
    • (2000) Ann Intern Med , vol.133 , pp. 855-863
    • Kerlikowske, K.1    Carney, P.A.2    Geller, B.3
  • 18
    • 0037418128 scopus 로고    scopus 로고
    • Individual and combined effects of age, breast density, and hormone replacement therapy use on the accuracy of screening mammography
    • Carney P.A., Miglioretti D.L., Yankaskas B.C., et al. Individual and combined effects of age, breast density, and hormone replacement therapy use on the accuracy of screening mammography. Ann Intern Med 138 (2003) 168-175
    • (2003) Ann Intern Med , vol.138 , pp. 168-175
    • Carney, P.A.1    Miglioretti, D.L.2    Yankaskas, B.C.3
  • 19
  • 20
    • 0028909276 scopus 로고
    • Breast cancer diagnosis in women with subglandular silicone gel-filled augmentation implants
    • Fajardo L.L., Harvey J.A., McAleese K.A., et al. Breast cancer diagnosis in women with subglandular silicone gel-filled augmentation implants. Radiology 194 (1995) 859-862
    • (1995) Radiology , vol.194 , pp. 859-862
    • Fajardo, L.L.1    Harvey, J.A.2    McAleese, K.A.3
  • 21
    • 0027503348 scopus 로고
    • Breast cancer after mammary augmentation
    • Schirber S., Thomas W.O., Finley J.M., et al. Breast cancer after mammary augmentation. South Med J 86 (1993) 263-268
    • (1993) South Med J , vol.86 , pp. 263-268
    • Schirber, S.1    Thomas, W.O.2    Finley, J.M.3
  • 22
    • 0025128668 scopus 로고
    • Breast cancer: mammographic and sonographic findings after augmentation mammoplasty
    • Leibman A.J., and Kruse B. Breast cancer: mammographic and sonographic findings after augmentation mammoplasty. Radiology 174 (1990) 195-198
    • (1990) Radiology , vol.174 , pp. 195-198
    • Leibman, A.J.1    Kruse, B.2
  • 23
    • 0024544914 scopus 로고
    • Mammography after prosthesis placement for augmentation or reconstructive mammoplasty
    • Dershaw D.D., and Chaglassian T.A. Mammography after prosthesis placement for augmentation or reconstructive mammoplasty. Radiology 170 (1989) 69-74
    • (1989) Radiology , vol.170 , pp. 69-74
    • Dershaw, D.D.1    Chaglassian, T.A.2
  • 24
    • 0024576299 scopus 로고
    • Mammographic detection of carcinoma of the breast in patients with augmentation prostheses
    • Mitnick J.S., Harris M.N., and Roses D.F. Mammographic detection of carcinoma of the breast in patients with augmentation prostheses. Surg Gynecol Obstet 168 (1989) 30-32
    • (1989) Surg Gynecol Obstet , vol.168 , pp. 30-32
    • Mitnick, J.S.1    Harris, M.N.2    Roses, D.F.3
  • 25
    • 0026100638 scopus 로고
    • Roentgenographic evaluation of the augmented breast
    • Douglas K.P., Bluth E.I., Sauter E.R., et al. Roentgenographic evaluation of the augmented breast. South Med J 84 (1991) 49-54
    • (1991) South Med J , vol.84 , pp. 49-54
    • Douglas, K.P.1    Bluth, E.I.2    Sauter, E.R.3
  • 26
    • 0027172250 scopus 로고
    • Cancer in the augmented breast. Diagnosis and prognosis
    • Clark III C.P., Peters G.N., and O'Brien K.M. Cancer in the augmented breast. Diagnosis and prognosis. Cancer 72 (1993) 2170-2174
    • (1993) Cancer , vol.72 , pp. 2170-2174
    • Clark III, C.P.1    Peters, G.N.2    O'Brien, K.M.3
  • 27
    • 0027403170 scopus 로고
    • The detection of breast cancer after augmentation mammaplasty
    • Carlson G.W., Curley S.A., Martin J.E., et al. The detection of breast cancer after augmentation mammaplasty. Plast Reconstr Surg 91 (1993) 837-840
    • (1993) Plast Reconstr Surg , vol.91 , pp. 837-840
    • Carlson, G.W.1    Curley, S.A.2    Martin, J.E.3
  • 28
    • 0025040938 scopus 로고
    • The role of mammography in detecting breast cancer in augmented breasts
    • Grace G.T., Roberts C., and Cohen I.K. The role of mammography in detecting breast cancer in augmented breasts. Ann Plast Surg 25 (1990) 119-123
    • (1990) Ann Plast Surg , vol.25 , pp. 119-123
    • Grace, G.T.1    Roberts, C.2    Cohen, I.K.3
  • 29
    • 0038338494 scopus 로고    scopus 로고
    • What is the impact of breast augmentation on the Breast Screening Programme?
    • Colville R.J., Mallen C.A., McLean L., et al. What is the impact of breast augmentation on the Breast Screening Programme?. Eur J Surg Oncol 29 (2003) 434-436
    • (2003) Eur J Surg Oncol , vol.29 , pp. 434-436
    • Colville, R.J.1    Mallen, C.A.2    McLean, L.3
  • 30
    • 0028873854 scopus 로고
    • Mammography and breast implants
    • Bantick G.L., and Taggart I. Mammography and breast implants. Br J Plast Surg 48 (1995) 49-52
    • (1995) Br J Plast Surg , vol.48 , pp. 49-52
    • Bantick, G.L.1    Taggart, I.2
  • 31
    • 0025123391 scopus 로고
    • The role of US in breast imaging
    • Jackson V.P. The role of US in breast imaging. Radiology 177 (1990) 305-311
    • (1990) Radiology , vol.177 , pp. 305-311
    • Jackson, V.P.1
  • 32
    • 0027251823 scopus 로고
    • Silicone implant rupture: detection with US
    • Harris K.M., Ganott M.A., Shestak K.C., et al. Silicone implant rupture: detection with US. Radiology 187 (1993) 761-768
    • (1993) Radiology , vol.187 , pp. 761-768
    • Harris, K.M.1    Ganott, M.A.2    Shestak, K.C.3
  • 33
    • 0026700085 scopus 로고
    • Ruptured gel-filled silicone breast implants: sonographic findings in 19 cases
    • Rosculet K.A., Ikeda D.M., Forrest M.E., et al. Ruptured gel-filled silicone breast implants: sonographic findings in 19 cases. AJR Am J Roentgenol 159 (1992) 711-716
    • (1992) AJR Am J Roentgenol , vol.159 , pp. 711-716
    • Rosculet, K.A.1    Ikeda, D.M.2    Forrest, M.E.3
  • 34
    • 0019849777 scopus 로고
    • Ultrasonic findings in silicone-augmented breasts
    • Rosenbaum J.L., Bernardino M.E., Thomas J.L., et al. Ultrasonic findings in silicone-augmented breasts. South Med J 74 (1981) 455-458
    • (1981) South Med J , vol.74 , pp. 455-458
    • Rosenbaum, J.L.1    Bernardino, M.E.2    Thomas, J.L.3
  • 35
    • 0027461797 scopus 로고
    • Imaging of breast cancer after augmentation mammoplasty
    • Leibman A.J., and Kruse B.D. Imaging of breast cancer after augmentation mammoplasty. Ann Plast Surg 30 (1993) 111-115
    • (1993) Ann Plast Surg , vol.30 , pp. 111-115
    • Leibman, A.J.1    Kruse, B.D.2
  • 36
    • 0023949070 scopus 로고
    • Nuclear magnetic resonance in the diagnosis of breast cancer
    • Turner D.A., Alcorn F.S., and Adler Y.T. Nuclear magnetic resonance in the diagnosis of breast cancer. Radiol Clin North Am 26 (1988) 673-687
    • (1988) Radiol Clin North Am , vol.26 , pp. 673-687
    • Turner, D.A.1    Alcorn, F.S.2    Adler, Y.T.3
  • 37
    • 0026080639 scopus 로고
    • The role of magnetic resonance imaging in the assessment of local recurrent breast carcinoma
    • Lewis-Jones H.G., Whitehouse G.H., and Leinster S.J. The role of magnetic resonance imaging in the assessment of local recurrent breast carcinoma. Clin Radiol 43 (1991) 197-204
    • (1991) Clin Radiol , vol.43 , pp. 197-204
    • Lewis-Jones, H.G.1    Whitehouse, G.H.2    Leinster, S.J.3
  • 38
    • 0028012286 scopus 로고
    • Suspicious breast lesions: MR imaging with radiologic-pathologic correlation
    • Orel S.G., Schnall M.D., LiVolsi V.A., et al. Suspicious breast lesions: MR imaging with radiologic-pathologic correlation. Radiology 190 (1994) 485-493
    • (1994) Radiology , vol.190 , pp. 485-493
    • Orel, S.G.1    Schnall, M.D.2    LiVolsi, V.A.3
  • 39
    • 0026661919 scopus 로고
    • Silicone breast implants in vivo: MR imaging
    • Gorczyca D.P., Sinha S., Ahn C.Y., et al. Silicone breast implants in vivo: MR imaging. Radiology 185 (1992) 407-410
    • (1992) Radiology , vol.185 , pp. 407-410
    • Gorczyca, D.P.1    Sinha, S.2    Ahn, C.Y.3
  • 40
    • 0028123757 scopus 로고
    • Silicone breast implant rupture: comparison between three-point Dixon and fast spin-echo MR imaging
    • Gorczyca D.P., Schneider E., DeBruhl N.D., et al. Silicone breast implant rupture: comparison between three-point Dixon and fast spin-echo MR imaging. AJR Am J Roentgenol 162 (1994) 305-310
    • (1994) AJR Am J Roentgenol , vol.162 , pp. 305-310
    • Gorczyca, D.P.1    Schneider, E.2    DeBruhl, N.D.3
  • 41
    • 0028012524 scopus 로고
    • Silicone breast implant ruptures in an animal model: comparison of mammography, MR imaging, US, and CT
    • Gorczyca D.P., DeBruhl N.D., Ahn C.Y., et al. Silicone breast implant ruptures in an animal model: comparison of mammography, MR imaging, US, and CT. Radiology 190 (1994) 227-232
    • (1994) Radiology , vol.190 , pp. 227-232
    • Gorczyca, D.P.1    DeBruhl, N.D.2    Ahn, C.Y.3
  • 42
    • 0021165101 scopus 로고
    • Fine needle aspiration cytology, in relationships to clinical examination and mammography in the diagnosis of a solid breast mass
    • Dixon J.M., Anderson T.J., Lamb J., et al. Fine needle aspiration cytology, in relationships to clinical examination and mammography in the diagnosis of a solid breast mass. Br J Surg 71 (1984) 593-596
    • (1984) Br J Surg , vol.71 , pp. 593-596
    • Dixon, J.M.1    Anderson, T.J.2    Lamb, J.3
  • 43
    • 0027532320 scopus 로고
    • Clinical correlates of false-negative fine needle aspirations of the breast in a consecutive series of 1,005 patients
    • O'Malley F., Casey T.T., Winfield A.C., et al. Clinical correlates of false-negative fine needle aspirations of the breast in a consecutive series of 1,005 patients. Surg Gynecol Obstet 176 (1993) 360-364
    • (1993) Surg Gynecol Obstet , vol.176 , pp. 360-364
    • O'Malley, F.1    Casey, T.T.2    Winfield, A.C.3
  • 44
    • 0032804485 scopus 로고    scopus 로고
    • The accuracy of "one-stop" diagnosis for 1,110 patients presenting to a symptomatic breast clinic
    • Eltahir A., Jibril J.A., Squair J., et al. The accuracy of "one-stop" diagnosis for 1,110 patients presenting to a symptomatic breast clinic. J R Coll Surg Edinb 44 (1999) 226-230
    • (1999) J R Coll Surg Edinb , vol.44 , pp. 226-230
    • Eltahir, A.1    Jibril, J.A.2    Squair, J.3
  • 45
    • 0025365652 scopus 로고
    • The role of Tru-Cut needle biopsy in the diagnosis of carcinoma of the breast
    • Cusick J.D., Dotan J., Jaecks R.D., et al. The role of Tru-Cut needle biopsy in the diagnosis of carcinoma of the breast. Surg Gynecol Obstet 170 (1990) 407-410
    • (1990) Surg Gynecol Obstet , vol.170 , pp. 407-410
    • Cusick, J.D.1    Dotan, J.2    Jaecks, R.D.3
  • 46
    • 0032520104 scopus 로고    scopus 로고
    • Rate of insufficient samples for fine-needle aspiration for nonpalpable breast lesions in a multicenter clinical trial: The Radiologic Diagnostic Oncology Group 5 Study. The RDOG5 investigators
    • Pisano E.D., Fajardo L.L., Tsimikas J., et al. Rate of insufficient samples for fine-needle aspiration for nonpalpable breast lesions in a multicenter clinical trial: The Radiologic Diagnostic Oncology Group 5 Study. The RDOG5 investigators. Cancer 82 (1998) 679-688
    • (1998) Cancer , vol.82 , pp. 679-688
    • Pisano, E.D.1    Fajardo, L.L.2    Tsimikas, J.3
  • 47
    • 0031585831 scopus 로고    scopus 로고
    • Core needle biopsy. A useful adjunct to fine-needle aspiration in select patients with palpable breast lesions
    • Florentine B.D., Cobb C.J., Frankel K., et al. Core needle biopsy. A useful adjunct to fine-needle aspiration in select patients with palpable breast lesions. Cancer 81 (1997) 33-39
    • (1997) Cancer , vol.81 , pp. 33-39
    • Florentine, B.D.1    Cobb, C.J.2    Frankel, K.3
  • 48
    • 0028945014 scopus 로고
    • Core needle aspiration biopsy of palpable breast masses
    • Vega A., Garijo F., and Ortega E. Core needle aspiration biopsy of palpable breast masses. Acta Oncol 34 (1995) 31-34
    • (1995) Acta Oncol , vol.34 , pp. 31-34
    • Vega, A.1    Garijo, F.2    Ortega, E.3
  • 49
    • 0033862753 scopus 로고    scopus 로고
    • Palpable breast masses: is there a role for percutaneous imaging-guided core biopsy?
    • Liberman L., Ernberg L.A., Heerdt A., et al. Palpable breast masses: is there a role for percutaneous imaging-guided core biopsy?. AJR Am J Roentgenol 175 (2000) 779-787
    • (2000) AJR Am J Roentgenol , vol.175 , pp. 779-787
    • Liberman, L.1    Ernberg, L.A.2    Heerdt, A.3
  • 50
    • 0031079764 scopus 로고    scopus 로고
    • The diagnostic accuracy of core biopsy in palpable and non-palpable breast lesions
    • Pijnappel R.M., van Dalen A., Borel R., et al. The diagnostic accuracy of core biopsy in palpable and non-palpable breast lesions. Eur J Radiol 24 (1997) 120-123
    • (1997) Eur J Radiol , vol.24 , pp. 120-123
    • Pijnappel, R.M.1    van Dalen, A.2    Borel, R.3
  • 51
    • 0029759194 scopus 로고    scopus 로고
    • Stereotactic breast biopsy: improved tissue harvesting with the Mammotome
    • Burbank F., Parker S.H., and Fogarty T.J. Stereotactic breast biopsy: improved tissue harvesting with the Mammotome. Am Surg 62 (1996) 738-744
    • (1996) Am Surg , vol.62 , pp. 738-744
    • Burbank, F.1    Parker, S.H.2    Fogarty, T.J.3
  • 52
    • 0030774099 scopus 로고    scopus 로고
    • Stereotactic breast biopsy: comparison of 14- and 11-gauge Mammotome probe performance and complication rates
    • Burbank F. Stereotactic breast biopsy: comparison of 14- and 11-gauge Mammotome probe performance and complication rates. Am Surg 63 (1997) 988-995
    • (1997) Am Surg , vol.63 , pp. 988-995
    • Burbank, F.1
  • 53
    • 0034937917 scopus 로고    scopus 로고
    • Sonographically guided directional vacuum-assisted breast biopsy using a handheld device
    • Parker S.H., Klaus A.J., McWey P.J., et al. Sonographically guided directional vacuum-assisted breast biopsy using a handheld device. AJR Am J Roentgenol 177 (2001) 405-408
    • (2001) AJR Am J Roentgenol , vol.177 , pp. 405-408
    • Parker, S.H.1    Klaus, A.J.2    McWey, P.J.3
  • 54
    • 0034094967 scopus 로고    scopus 로고
    • Accuracy and complication rates of US-guided vacuum-assisted core breast biopsy: initial results
    • Simon J.R., Kalbhen C.L., Cooper R.A., et al. Accuracy and complication rates of US-guided vacuum-assisted core breast biopsy: initial results. Radiology 215 (2000) 694-697
    • (2000) Radiology , vol.215 , pp. 694-697
    • Simon, J.R.1    Kalbhen, C.L.2    Cooper, R.A.3
  • 55
    • 0027317740 scopus 로고
    • Localization of nonpalpable masses in patients with breast implants
    • Mitnick J.S., Vazquez M.F., Colen S.R., et al. Localization of nonpalpable masses in patients with breast implants. Ann Plast Surg 31 (1993) 238-240
    • (1993) Ann Plast Surg , vol.31 , pp. 238-240
    • Mitnick, J.S.1    Vazquez, M.F.2    Colen, S.R.3
  • 56
    • 0024314207 scopus 로고
    • Nonpalpable lesions in the augmented breast: preoperative localization
    • Robertson C.L., Kopans D.B., McCarthy K.A., et al. Nonpalpable lesions in the augmented breast: preoperative localization. Radiology 173 (1989) 873-874
    • (1989) Radiology , vol.173 , pp. 873-874
    • Robertson, C.L.1    Kopans, D.B.2    McCarthy, K.A.3
  • 57
    • 0027282591 scopus 로고
    • Fine needle aspiration biopsy in patients with augmentation prostheses and a palpable mass
    • Mitnick J.S., Vazquez M.F., Plesser K., et al. Fine needle aspiration biopsy in patients with augmentation prostheses and a palpable mass. Ann Plast Surg 31 (1993) 241-244
    • (1993) Ann Plast Surg , vol.31 , pp. 241-244
    • Mitnick, J.S.1    Vazquez, M.F.2    Plesser, K.3
  • 58
    • 0026632411 scopus 로고
    • Stereotactic localization for fine needle aspiration biopsy in patients with augmentation prostheses
    • Mitnick J.S., Vazquez M.F., Roses D.F., et al. Stereotactic localization for fine needle aspiration biopsy in patients with augmentation prostheses. Ann Plast Surg 29 (1992) 31-35
    • (1992) Ann Plast Surg , vol.29 , pp. 31-35
    • Mitnick, J.S.1    Vazquez, M.F.2    Roses, D.F.3
  • 59
    • 0028208427 scopus 로고
    • Masses in breasts with implants: diagnosis with US-guided fine-needle aspiration biopsy
    • Fornage B.D., Sneige N., and Singletary S.E. Masses in breasts with implants: diagnosis with US-guided fine-needle aspiration biopsy. Radiology 191 (1994) 339-342
    • (1994) Radiology , vol.191 , pp. 339-342
    • Fornage, B.D.1    Sneige, N.2    Singletary, S.E.3
  • 60
    • 0036135288 scopus 로고    scopus 로고
    • Stereotactic histologic biopsy in breasts with implants
    • Jackman R.J., and Lamm R.L. Stereotactic histologic biopsy in breasts with implants. Radiology 222 (2002) 157-164
    • (2002) Radiology , vol.222 , pp. 157-164
    • Jackman, R.J.1    Lamm, R.L.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.