-
1
-
-
0029113587
-
Early treatment of ruptured aneurysms with Guglielmi detachable coils: Effect on subsequent bleeding
-
Graves V, Strother CM, Duff T, et al. Early treatment of ruptured aneurysms with Guglielmi detachable coils: effect on subsequent bleeding. Neurosurgery 1995;37:640-47
-
(1995)
Neurosurgery
, vol.37
, pp. 640-647
-
-
Graves, V.1
Strother, C.M.2
Duff, T.3
-
2
-
-
0030028661
-
Endovascular treatment of basilar tip aneurysms using electrolytically detachable coils
-
McDougall C, Halbach V, Dowd C, et al. Endovascular treatment of basilar tip aneurysms using electrolytically detachable coils. J Neurosurg 1996;84:393-99
-
(1996)
J Neurosurg
, vol.84
, pp. 393-399
-
-
McDougall, C.1
Halbach, V.2
Dowd, C.3
-
3
-
-
1842296356
-
Guglielmi detachable coil embolization of acute intracranial aneurysm: Perioperative anatomical and clinical outcome in 403 patients
-
Vinuela F, Duckwiler G, Mawad M. Guglielmi detachable coil embolization of acute intracranial aneurysm: perioperative anatomical and clinical outcome in 403 patients. J Neurosurg 1997;86:475-82
-
(1997)
J Neurosurg
, vol.86
, pp. 475-482
-
-
Vinuela, F.1
Duckwiler, G.2
Mawad, M.3
-
4
-
-
0033062709
-
Five-year experience in using coil embolization for ruptured intracranial aneurysms: Outcomes and incidence of late rebleeding
-
Byrne J, Sohn M, Molyneux A, et al. Five-year experience in using coil embolization for ruptured intracranial aneurysms: outcomes and incidence of late rebleeding. J Neurosurg 1999;90:656-63
-
(1999)
J Neurosurg
, vol.90
, pp. 656-663
-
-
Byrne, J.1
Sohn, M.2
Molyneux, A.3
-
5
-
-
0032768267
-
Long-term angiographic follow-up of 169 intracranial berry aneurysms occluded with detachable coils
-
Cognard C, Weill A, Spelle L, et al. Long-term angiographic follow-up of 169 intracranial berry aneurysms occluded with detachable coils. Radiology 1999;212:348-56
-
(1999)
Radiology
, vol.212
, pp. 348-356
-
-
Cognard, C.1
Weill, A.2
Spelle, L.3
-
6
-
-
0032948321
-
Treatment of basilar artery bifurcation aneurysms by using Guglielmi detachable coils: A 6-year experience
-
Bavinzski G, Killer M, Gruber A, et al. Treatment of basilar artery bifurcation aneurysms by using Guglielmi detachable coils: a 6-year experience. J Neurosurg 1999;90:843-52
-
(1999)
J Neurosurg
, vol.90
, pp. 843-852
-
-
Bavinzski, G.1
Killer, M.2
Gruber, A.3
-
7
-
-
0034433325
-
Natural history of the neck remnant of a cerebral aneurysm treated with the Guglielmi detachable coil system
-
Hayakawa M, Murayama Y, Duckwiler G, et al. Natural history of the neck remnant of a cerebral aneurysm treated with the Guglielmi detachable coil system. J Neurosurg 2000;93:561-68
-
(2000)
J Neurosurg
, vol.93
, pp. 561-568
-
-
Hayakawa, M.1
Murayama, Y.2
Duckwiler, G.3
-
8
-
-
1642541684
-
Aneurysm packing with HydroCoil embolic system versus platinum coils: Initial clinical experience
-
Cloft HJ, Kallmes DF. Aneurysm packing with HydroCoil embolic system versus platinum coils: initial clinical experience. AJNR Am J Neuroradiol 2004;25:60-62
-
(2004)
AJNR Am J Neuroradiol
, vol.25
, pp. 60-62
-
-
Cloft, H.J.1
Kallmes, D.F.2
-
9
-
-
0036094962
-
Evaluation of the stability of aneurysms after embolization using detachable coils: Correlation between stability of aneurysms and embolized volume of aneurysms
-
Tamatani S, Ito Y, Abe H, et al. Evaluation of the stability of aneurysms after embolization using detachable coils: correlation between stability of aneurysms and embolized volume of aneurysms. AJNR Am J Neuroradiol 2002;23:762-67
-
(2002)
AJNR Am J Neuroradiol
, vol.23
, pp. 762-767
-
-
Tamatani, S.1
Ito, Y.2
Abe, H.3
-
10
-
-
2442640381
-
Relation between aneurysm volume, packing, and compaction in 145 cerebral aneurysms treated with coils
-
Sluzewski M, van Rooij W, Slob M, et al. Relation between aneurysm volume, packing, and compaction in 145 cerebral aneurysms treated with coils. Radiology 2004;231:653-58
-
(2004)
Radiology
, vol.231
, pp. 653-658
-
-
Sluzewski, M.1
van Rooij, W.2
Slob, M.3
-
11
-
-
0033978426
-
ARRS Executive Council Award: Creation of saccular aneurysms in the rabbit - a model suitable for testing endovascular devices. American Roentgen Ray Society
-
Altes TA, Cloft HJ, Short JG, et al. 1999 ARRS Executive Council Award: creation of saccular aneurysms in the rabbit - a model suitable for testing endovascular devices. American Roentgen Ray Society. AJR Am J Roentgenol 2000;174:349-54
-
(1999)
AJR Am J Roentgenol
, vol.2000
, Issue.174
, pp. 349-354
-
-
Altes, T.A.1
Cloft, H.J.2
Short, J.G.3
-
12
-
-
0035044409
-
Serial angiography in an elastase-induced aneurysm model in rabbits: Evidence for progressive aneurysm enlargement after creation
-
Fujiwara NH, Cloft HJ, Marx WF, et al. Serial angiography in an elastase-induced aneurysm model in rabbits: evidence for progressive aneurysm enlargement after creation. AJNR Am J Neuroradiol 2001;22:698-703
-
(2001)
AJNR Am J Neuroradiol
, vol.22
, pp. 698-703
-
-
Fujiwara, N.H.1
Cloft, H.J.2
Marx, W.F.3
-
13
-
-
0347708683
-
A collagen-based coil for embolization of saccular aneurysms in a New Zealand white rabbit model
-
Kallmes DF, Fujiwara NH, Yuen D, et al. A collagen-based coil for embolization of saccular aneurysms in a New Zealand white rabbit model. AJNR Am J Neuroradiol 2003;24:591-96
-
(2003)
AJNR Am J Neuroradiol
, vol.24
, pp. 591-596
-
-
Kallmes, D.F.1
Fujiwara, N.H.2
Yuen, D.3
-
14
-
-
24344467495
-
Angiographic and histologic analysis of experimental aneurysms embolized with platinum coils, Matrix, and HydroCoil
-
Ding YH, Dai D, Lewis DA, et al. Angiographic and histologic analysis of experimental aneurysms embolized with platinum coils, Matrix, and HydroCoil. AJNR Am J Neuroradiol 2005;26:1757-63
-
(2005)
AJNR Am J Neuroradiol
, vol.26
, pp. 1757-1763
-
-
Ding, Y.H.1
Dai, D.2
Lewis, D.A.3
-
15
-
-
32944482209
-
Modified histologic technique for processing metallic coil-bearing tissue
-
Dai D, Ding YH, Danielson MA, et al. Modified histologic technique for processing metallic coil-bearing tissue. AJNR Am J Neuroradiol 2005;26:1932-36
-
(2005)
AJNR Am J Neuroradiol
, vol.26
, pp. 1932-1936
-
-
Dai, D.1
Ding, Y.H.2
Danielson, M.A.3
-
16
-
-
33644867976
-
A proposed ordinal scale for grading histology in elastase-induced, saccular aneurysms
-
Dai D, Ding YH, Lewis DA, et al. A proposed ordinal scale for grading histology in elastase-induced, saccular aneurysms. AJNR Am J Neuroradiol 2006;27:132-38
-
(2006)
AJNR Am J Neuroradiol
, vol.27
, pp. 132-138
-
-
Dai, D.1
Ding, Y.H.2
Lewis, D.A.3
-
17
-
-
0030724481
-
Endovascular occlusion of experimental aneurysms with detachable coils: Influence of packing density and perioperative anticoagulation
-
Reul J, Spetzger U, Weis J, et al. Endovascular occlusion of experimental aneurysms with detachable coils: influence of packing density and perioperative anticoagulation. Neurosurgery 1997;41:1160-65
-
(1997)
Neurosurgery
, vol.41
, pp. 1160-1165
-
-
Reul, J.1
Spetzger, U.2
Weis, J.3
-
18
-
-
0036793782
-
New expandable hydrogel-platinum coil hybrid device for aneurysm embolization
-
Kallmes DF, Fujiwara NH. New expandable hydrogel-platinum coil hybrid device for aneurysm embolization. AJNR Am J Neuroradiol 2002;23:1580-88
-
(2002)
AJNR Am J Neuroradiol
, vol.23
, pp. 1580-1588
-
-
Kallmes, D.F.1
Fujiwara, N.H.2
-
19
-
-
0029069722
-
Histological findings in giant aneurysms treated with Guglielmi detachable coils: Report of two cases with autopsy correlation
-
Molyneux A, Ellison D, Morris J, et al. Histological findings in giant aneurysms treated with Guglielmi detachable coils: report of two cases with autopsy correlation. J Neurosurg 1995;83:129-32
-
(1995)
J Neurosurg
, vol.83
, pp. 129-132
-
-
Molyneux, A.1
Ellison, D.2
Morris, J.3
-
20
-
-
0029901816
-
A pitfall in the surgery of a recurrent aneurysm after coil embolization and its histological observation: Technical case report
-
Mizoi K, Yoshimoto T, Takahashi A, et al. A pitfall in the surgery of a recurrent aneurysm after coil embolization and its histological observation: technical case report. Neurosurgery 1996;39:165-68
-
(1996)
Neurosurgery
, vol.39
, pp. 165-168
-
-
Mizoi, K.1
Yoshimoto, T.2
Takahashi, A.3
|