-
1
-
-
4644241352
-
Early bone formation adjacent to rough and turned endosseous implants surfaces. An experimental study in the dog
-
Abrahamsson I., Berglundh T., Linder E., Lang N.P., and Lindhe J. Early bone formation adjacent to rough and turned endosseous implants surfaces. An experimental study in the dog. Clinical Oral Implants Research 15 (2004) 381-392
-
(2004)
Clinical Oral Implants Research
, vol.15
, pp. 381-392
-
-
Abrahamsson, I.1
Berglundh, T.2
Linder, E.3
Lang, N.P.4
Lindhe, J.5
-
2
-
-
33750333907
-
A predictive mechano-biological model of the bone-implant healing
-
Ambard D., and Swider P. A predictive mechano-biological model of the bone-implant healing. European Journal of Mechanics-A-Solids 25 6 (2006) 927-937
-
(2006)
European Journal of Mechanics-A-Solids
, vol.25
, Issue.6
, pp. 927-937
-
-
Ambard, D.1
Swider, P.2
-
5
-
-
7944232457
-
Implant stability measurement of delayed and immediately loaded implants during healing
-
Bischof M., Nedir R., Szmukler-Moncler S., Bernard J.P., and Samson J. Implant stability measurement of delayed and immediately loaded implants during healing. Clinical Oral Implants Research 15 5 (2004) 529-539
-
(2004)
Clinical Oral Implants Research
, vol.15
, Issue.5
, pp. 529-539
-
-
Bischof, M.1
Nedir, R.2
Szmukler-Moncler, S.3
Bernard, J.P.4
Samson, J.5
-
7
-
-
38349029880
-
-
Branemark, P. I., 1985. Introduction to osseointegration. Tissue Integrated Prostheses. Quintessence Publishing, p. 11.
-
-
-
-
8
-
-
0026740505
-
Biomechanical factors affecting the bone-dental implant interface
-
Brunski J.B. Biomechanical factors affecting the bone-dental implant interface. Clinical Materials 10 (1992) 153-201
-
(1992)
Clinical Materials
, vol.10
, pp. 153-201
-
-
Brunski, J.B.1
-
9
-
-
0345770592
-
A behavioral comparison of New Zealand White rabbits (Oryctolagus cuniculus) housed individually or inpairs in conventional laboratory cages
-
Chu L., Garner J.P., and Mench J.A. A behavioral comparison of New Zealand White rabbits (Oryctolagus cuniculus) housed individually or inpairs in conventional laboratory cages. Applied Animal Behaviour Science 85 (2004) 121-139
-
(2004)
Applied Animal Behaviour Science
, vol.85
, pp. 121-139
-
-
Chu, L.1
Garner, J.P.2
Mench, J.A.3
-
10
-
-
38349000066
-
-
Dassault Systemes Simulia Corp., 2006. Abaqus User's Manual, v. 6.6. Providence, RI, USA.
-
-
-
-
11
-
-
0141608016
-
Understanding peri-implant endosseous healing
-
Davies J.E. Understanding peri-implant endosseous healing. Journal of Dental Education 67 (2003) 932-949
-
(2003)
Journal of Dental Education
, vol.67
, pp. 932-949
-
-
Davies, J.E.1
-
12
-
-
0242315518
-
On the effects of cyclic transversal forces on osseointegrated dental implants: experimental and finite element shakedown analyses
-
Genna F. On the effects of cyclic transversal forces on osseointegrated dental implants: experimental and finite element shakedown analyses. Computer Methods in Biomechanics and Biomedical Engineering 6 2 (2003) 141-152
-
(2003)
Computer Methods in Biomechanics and Biomedical Engineering
, vol.6
, Issue.2
, pp. 141-152
-
-
Genna, F.1
-
13
-
-
38349017653
-
Accurate diagnosis of hip prosthesis loosening using a vibrational technique
-
Georgiou A.P., and Cunningham J.L. Accurate diagnosis of hip prosthesis loosening using a vibrational technique. Clinical Biomechanics 18 (1997) 715-719
-
(1997)
Clinical Biomechanics
, vol.18
, pp. 715-719
-
-
Georgiou, A.P.1
Cunningham, J.L.2
-
14
-
-
4644230057
-
Resonance frequency analysis of implants subjected to immediate or early functional occlusal loading
-
Glauser R., Sennerby L., Meredith N., Ree A., Lundgren A., Gottlow J., and Hämmerle C.H.F. Resonance frequency analysis of implants subjected to immediate or early functional occlusal loading. Clinical Oral Implants Research 15 (2004) 428-434
-
(2004)
Clinical Oral Implants Research
, vol.15
, pp. 428-434
-
-
Glauser, R.1
Sennerby, L.2
Meredith, N.3
Ree, A.4
Lundgren, A.5
Gottlow, J.6
Hämmerle, C.H.F.7
-
15
-
-
21844461292
-
Rabbit knee joint biomechanics: motion analysis and modeling of forces during hopping
-
Gushue D.L., Houck J., and Lerner A.L. Rabbit knee joint biomechanics: motion analysis and modeling of forces during hopping. Journal of Orthopaedic Research 23 (2005) 735-742
-
(2005)
Journal of Orthopaedic Research
, vol.23
, pp. 735-742
-
-
Gushue, D.L.1
Houck, J.2
Lerner, A.L.3
-
16
-
-
0034630874
-
The effect of environmental enrichment on the behaviour of caged rabbits (Oryctolagus cuniculus)
-
Hansen L.T., and Berthelsen H. The effect of environmental enrichment on the behaviour of caged rabbits (Oryctolagus cuniculus). Applied Animal Behaviour Science 68 (2000) 163-178
-
(2000)
Applied Animal Behaviour Science
, vol.68
, pp. 163-178
-
-
Hansen, L.T.1
Berthelsen, H.2
-
17
-
-
38349080225
-
-
Harpoon Sharc Ltd, 2006. Richard Bardwell. Empress Business Centre, Manchester, UK.
-
-
-
-
18
-
-
20544454321
-
Design of a stability-detecting device for dental implants
-
Huang H.M., Cheng K.Y., Chen C.H., Lin C.T., and Lee S.Y. Design of a stability-detecting device for dental implants. Proceedings of the Institution of Mechanical Engineering-Part H-Journal of Engineering in Medicine 219 (2005) 203-211
-
(2005)
Proceedings of the Institution of Mechanical Engineering-Part H-Journal of Engineering in Medicine
, vol.219
, pp. 203-211
-
-
Huang, H.M.1
Cheng, K.Y.2
Chen, C.H.3
Lin, C.T.4
Lee, S.Y.5
-
19
-
-
0141497384
-
Early detection of implant healing process using resonance frequency analysis
-
Huang H.M., Chiu C.L., Yeh C.Y., Lin C.T., Lin L.H., and Lee S.Y. Early detection of implant healing process using resonance frequency analysis. Clinical Oral Implants Research 14 4 (2003) 437-443
-
(2003)
Clinical Oral Implants Research
, vol.14
, Issue.4
, pp. 437-443
-
-
Huang, H.M.1
Chiu, C.L.2
Yeh, C.Y.3
Lin, C.T.4
Lin, L.H.5
Lee, S.Y.6
-
20
-
-
0036481346
-
Resonance frequency assessment of dental implant stability with various bone qualities: a numerical approach
-
Huang H.M., Lee S.Y., Yeh C.Y., and Lin C.T. Resonance frequency assessment of dental implant stability with various bone qualities: a numerical approach. Clinical Oral Implants Research 13 (2002) 65-74
-
(2002)
Clinical Oral Implants Research
, vol.13
, pp. 65-74
-
-
Huang, H.M.1
Lee, S.Y.2
Yeh, C.Y.3
Lin, C.T.4
-
21
-
-
0034268653
-
Assessing the implant/bone interface by using natural frequency analysis
-
Huang H.M., Pan L.C., Lee S.Y., Chiu C.L., Fan K.H., and Ho K.N. Assessing the implant/bone interface by using natural frequency analysis. Oral Surgery, Oral Medicine, Oral Pathology, Oral Radiology, and Endodontics 90 (2000) 285-291
-
(2000)
Oral Surgery, Oral Medicine, Oral Pathology, Oral Radiology, and Endodontics
, vol.90
, pp. 285-291
-
-
Huang, H.M.1
Pan, L.C.2
Lee, S.Y.3
Chiu, C.L.4
Fan, K.H.5
Ho, K.N.6
-
22
-
-
0037397187
-
In vivo forces used to develop design parameters for tissue engineered implants for rabbit patellar tendon repair
-
Juncosa N., West J.R., Galloway M.T., Boivin G.P., and Butler D.L. In vivo forces used to develop design parameters for tissue engineered implants for rabbit patellar tendon repair. Journal of Biomechanics 36 (2003) 483-488
-
(2003)
Journal of Biomechanics
, vol.36
, pp. 483-488
-
-
Juncosa, N.1
West, J.R.2
Galloway, M.T.3
Boivin, G.P.4
Butler, D.L.5
-
23
-
-
0028149722
-
Material-tissue interfaces: the role of surface properties and processes
-
Kasemo B., and Lausmaa J. Material-tissue interfaces: the role of surface properties and processes. Environmental Health Perspectives 102 5 (1994)
-
(1994)
Environmental Health Perspectives
, vol.102
, Issue.5
-
-
Kasemo, B.1
Lausmaa, J.2
-
24
-
-
0032953310
-
Implant fixation by bone in-growth
-
Kienapfel H., Sprey C., Wilke A., and Griss P. Implant fixation by bone in-growth. Journal of Arthroplasty 14 3 (1999) 355-368
-
(1999)
Journal of Arthroplasty
, vol.14
, Issue.3
, pp. 355-368
-
-
Kienapfel, H.1
Sprey, C.2
Wilke, A.3
Griss, P.4
-
25
-
-
4344673153
-
A fatigue damage model for the cement-bone interface
-
Kim D.G., Miller M.A., and Mann K.A. A fatigue damage model for the cement-bone interface. Journal of Biomechanics 37 (2004) 1505-1512
-
(2004)
Journal of Biomechanics
, vol.37
, pp. 1505-1512
-
-
Kim, D.G.1
Miller, M.A.2
Mann, K.A.3
-
26
-
-
1842853909
-
Creep dominates tensile fatigue damage of the cement-bone interface
-
Kim D.G., Miller M.A., and Mann K.A. Creep dominates tensile fatigue damage of the cement-bone interface. Journal of Orthopaedic Research 22 (2004) 633-640
-
(2004)
Journal of Orthopaedic Research
, vol.22
, pp. 633-640
-
-
Kim, D.G.1
Miller, M.A.2
Mann, K.A.3
-
27
-
-
0030271435
-
Vibration analysis in the detection of total hip prosthetic loosening
-
Li P.L.S., Jones N.B., and Gregg P.J. Vibration analysis in the detection of total hip prosthetic loosening. Medical Engineering and Physics 18 7 (1996) 596-600
-
(1996)
Medical Engineering and Physics
, vol.18
, Issue.7
, pp. 596-600
-
-
Li, P.L.S.1
Jones, N.B.2
Gregg, P.J.3
-
29
-
-
0030221980
-
Study of the vibrational behaviour of a healing tibia using finite element modelling
-
Lowet G., Dayuan X., and Van der Perre G. Study of the vibrational behaviour of a healing tibia using finite element modelling. Journal of Biomechanics 29 8 (1996) 141-152
-
(1996)
Journal of Biomechanics
, vol.29
, Issue.8
, pp. 141-152
-
-
Lowet, G.1
Dayuan, X.2
Van der Perre, G.3
-
30
-
-
0032212081
-
In vivo tendon forces correlate with activity level and remain bounded: evidence in a rabbit flexor tendom model
-
Malaviya P., Butler D.L., Korvick D.L., and Proch F.S. In vivo tendon forces correlate with activity level and remain bounded: evidence in a rabbit flexor tendom model. Journal of Biomechanics 31 (1998) 1043-1049
-
(1998)
Journal of Biomechanics
, vol.31
, pp. 1043-1049
-
-
Malaviya, P.1
Butler, D.L.2
Korvick, D.L.3
Proch, F.S.4
-
31
-
-
0030224153
-
Quantitative determination of the stability of the implant-tissue interface using resonance frequency analysis
-
Meredith N., Alleyne D., and Cawley P. Quantitative determination of the stability of the implant-tissue interface using resonance frequency analysis. Clinical Oral Implants Research 7 (1996) 261-267
-
(1996)
Clinical Oral Implants Research
, vol.7
, pp. 261-267
-
-
Meredith, N.1
Alleyne, D.2
Cawley, P.3
-
32
-
-
0031152150
-
Resonance frequency measurement of implant stability in vivo. A cross-sectional and longitudinal study of resonance frequency measurements on implants in the edentulous and partially dentate maxilla
-
Meredith N., Book K., Friberg B., Jemt T., and Sennerby L. Resonance frequency measurement of implant stability in vivo. A cross-sectional and longitudinal study of resonance frequency measurements on implants in the edentulous and partially dentate maxilla. Clinical Oral Implants Research 8 (1997) 226-233
-
(1997)
Clinical Oral Implants Research
, vol.8
, pp. 226-233
-
-
Meredith, N.1
Book, K.2
Friberg, B.3
Jemt, T.4
Sennerby, L.5
-
33
-
-
0031152189
-
The application of resonance frequency measurements to study the stability of titanium implants during healing in the rabbit tibia
-
Meredith N., Shagaldi F., Alleyne D., Sennerby L., and Cawley P. The application of resonance frequency measurements to study the stability of titanium implants during healing in the rabbit tibia. Clinical Oral Implants Research 8 (1997) 234-243
-
(1997)
Clinical Oral Implants Research
, vol.8
, pp. 234-243
-
-
Meredith, N.1
Shagaldi, F.2
Alleyne, D.3
Sennerby, L.4
Cawley, P.5
-
34
-
-
38349000065
-
-
Mimics Materialise, 2006. Mimics Materialise NV v10.0.
-
-
-
-
35
-
-
33745849213
-
Bone-implant interface shear modulus and ultimate stress in a transcortical rabbit model of open-pore Ti6Al4V implants
-
Müller M., Hennig F.F., Hothorn T., and Stangl R. Bone-implant interface shear modulus and ultimate stress in a transcortical rabbit model of open-pore Ti6Al4V implants. Journal of Biomechanics 39 11 (2006) 2123-2132
-
(2006)
Journal of Biomechanics
, vol.39
, Issue.11
, pp. 2123-2132
-
-
Müller, M.1
Hennig, F.F.2
Hothorn, T.3
Stangl, R.4
-
36
-
-
34848900448
-
-
Moreo, P., García-Aznar, J.M., Doblaré, M., 2007a. A coupled viscoplastic rate-dependent damage model for the simulation of fatigue failure of cement-bone interfaces. International Journal of Plasticity. URL: doi:10.1016/j.ijplas.2007.02.05.
-
-
-
-
38
-
-
34250158575
-
Resonance frequency analysis of implants in the guinea pig model: influence of boundary conditions and orientation of the transdcucer
-
Pattijn V., Jaecques S.V.N., De Smet E., Muraru L., Van Lierde C., Van der Perre G., Naert I., and Vander Sloten J. Resonance frequency analysis of implants in the guinea pig model: influence of boundary conditions and orientation of the transdcucer. Medical Engineering and Physics 29 (2007) 182-190
-
(2007)
Medical Engineering and Physics
, vol.29
, pp. 182-190
-
-
Pattijn, V.1
Jaecques, S.V.N.2
De Smet, E.3
Muraru, L.4
Van Lierde, C.5
Van der Perre, G.6
Naert, I.7
Vander Sloten, J.8
-
39
-
-
32644436644
-
The resonance frequency and mode shapes of dental implants: Rigid body behaviour versus bending behaviour
-
Pattijn V., Van Lierde C., Van der Perre G., Naert I., and Vander Sloten J. The resonance frequency and mode shapes of dental implants: Rigid body behaviour versus bending behaviour. A numerical approach. Journal of Biomechanics 39 5 (2006) 939-947
-
(2006)
A numerical approach. Journal of Biomechanics
, vol.39
, Issue.5
, pp. 939-947
-
-
Pattijn, V.1
Van Lierde, C.2
Van der Perre, G.3
Naert, I.4
Vander Sloten, J.5
-
40
-
-
33745368973
-
Probabilistic analysis of the influence of bonding degree in stem-cement interfaces in cemented hip prosthesis
-
Pérez M.A., Grasa J., García-Aznar J.M., Bea J.A., and Doblaré M. Probabilistic analysis of the influence of bonding degree in stem-cement interfaces in cemented hip prosthesis. Journal of Biomechanics 39 (2006) 1859-1872
-
(2006)
Journal of Biomechanics
, vol.39
, pp. 1859-1872
-
-
Pérez, M.A.1
Grasa, J.2
García-Aznar, J.M.3
Bea, J.A.4
Doblaré, M.5
-
41
-
-
34250894953
-
Random-walk models of cell dispersal included in mechanobiological simulations of tissue differentiation
-
Pérez M.A., and Prendergast P.J. Random-walk models of cell dispersal included in mechanobiological simulations of tissue differentiation. Journal of Biomechanics 40 10 (2007) 2244-2253
-
(2007)
Journal of Biomechanics
, vol.40
, Issue.10
, pp. 2244-2253
-
-
Pérez, M.A.1
Prendergast, P.J.2
-
42
-
-
0038246468
-
How much can a vibrational diagnostic tool reveal in total hip arthroplasty loosening?
-
Qi G., Mouchon W.P., and Tan T.E. How much can a vibrational diagnostic tool reveal in total hip arthroplasty loosening?. Clinical Biomechanics 18 (2003) 444-458
-
(2003)
Clinical Biomechanics
, vol.18
, pp. 444-458
-
-
Qi, G.1
Mouchon, W.P.2
Tan, T.E.3
-
43
-
-
0027592281
-
Early bone tissue responses to titanium implants inserted in rabbit cortical bone (I). Light microscopic observations
-
Sennerby L., Thomsen P., and Ericson L.E. Early bone tissue responses to titanium implants inserted in rabbit cortical bone (I). Light microscopic observations. Journal of Materials Science. Materials in Medicine 4 (1993) 240-250
-
(1993)
Journal of Materials Science. Materials in Medicine
, vol.4
, pp. 240-250
-
-
Sennerby, L.1
Thomsen, P.2
Ericson, L.E.3
-
45
-
-
0026832935
-
Titanium and hydroxyapatite-coated implants
-
Søballe K., Hansen E.S., Rasmussen H.B., Jorgensen P.H., and Bünger C. Titanium and hydroxyapatite-coated implants. Journal of Orthopaedic Research 10 2 (1992) 285-299
-
(1992)
Journal of Orthopaedic Research
, vol.10
, Issue.2
, pp. 285-299
-
-
Søballe, K.1
Hansen, E.S.2
Rasmussen, H.B.3
Jorgensen, P.H.4
Bünger, C.5
-
46
-
-
0026521288
-
Hydroxyapatite coating modifies implant membrane formation. Controlled micromotion studied in dogs
-
Søballe K., Rasmussen H.B., Hansen E.S., and Bünger C. Hydroxyapatite coating modifies implant membrane formation. Controlled micromotion studied in dogs. Acta Orthopaedica Scandinava 63 2 (1992) 128-140
-
(1992)
Acta Orthopaedica Scandinava
, vol.63
, Issue.2
, pp. 128-140
-
-
Søballe, K.1
Rasmussen, H.B.2
Hansen, E.S.3
Bünger, C.4
-
47
-
-
38349015686
-
-
UGS Corp., 2005. I-DEAS Master Series Release 9.0. Plano, TX, USA.
-
-
-
-
48
-
-
0032229511
-
The influence of bone mechanical properties and implant fixation upon bone loading around oral implants
-
Van Oosterwyck H., Duyck J., Vander Sloten J., Van der Perre G., De Cooman M., Lievens S., Puers R., and Naert I. The influence of bone mechanical properties and implant fixation upon bone loading around oral implants. Clinical Oral Implants Research 9 (1998) 407-418
-
(1998)
Clinical Oral Implants Research
, vol.9
, pp. 407-418
-
-
Van Oosterwyck, H.1
Duyck, J.2
Vander Sloten, J.3
Van der Perre, G.4
De Cooman, M.5
Lievens, S.6
Puers, R.7
Naert, I.8
-
49
-
-
4544308123
-
Characterization of in vivo Achilles tendon forces in rabbits during treadmill locomotion at varying speeds and inclinations
-
West J.R., Juncosa N., Galloway M.T., Boivin G.P., and Butler D.L. Characterization of in vivo Achilles tendon forces in rabbits during treadmill locomotion at varying speeds and inclinations. Journal of Biomechanics 37 (2004) 1647-1653
-
(2004)
Journal of Biomechanics
, vol.37
, pp. 1647-1653
-
-
West, J.R.1
Juncosa, N.2
Galloway, M.T.3
Boivin, G.P.4
Butler, D.L.5
-
50
-
-
0031148742
-
Impulse response of a dental implant in bone by numerical analysis
-
Williams K.R., and Williams A.D.C. Impulse response of a dental implant in bone by numerical analysis. Biomaterials 18 (1997) 715-719
-
(1997)
Biomaterials
, vol.18
, pp. 715-719
-
-
Williams, K.R.1
Williams, A.D.C.2
|