메뉴 건너뛰기




Volumn 22, Issue 6, 2007, Pages 948-954

A pilot study to assess the performance of a partially threaded sintered porous-surfaced dental implant in the dog mandible

Author keywords

Coronal threaded collar; Crestal bone loss; Implant design; Machined smooth collar

Indexed keywords

ANIMAL; ARTICLE; BONE REGENERATION; COMPARATIVE STUDY; DOG; EDENTULOUSNESS; EVALUATION; FOLLOW UP; JAW DISEASE; MALE; MANDIBLE; OSTEOLYSIS; PILOT STUDY; POROSITY; SURFACE PROPERTY; TOOTH IMPLANTATION; TOOTH PROSTHESIS;

EID: 38149126550     PISSN: 08822786     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (5)

References (33)
  • 1
  • 3
    • 0032249955 scopus 로고    scopus 로고
    • An overview of surface variability of metallic endosseous dental implants: Textured and porous-surfaced designs
    • Pilliar RM. An overview of surface variability of metallic endosseous dental implants: Textured and porous-surfaced designs. Implant Dent 1998;7:305-314.
    • (1998) Implant Dent , vol.7 , pp. 305-314
    • Pilliar, R.M.1
  • 4
    • 3543026382 scopus 로고    scopus 로고
    • A targeted review of study outcomes with short (≤ 7 mm) endosseous dental implants placed in partially edentulous patients
    • Hagi D, Deporter DA, Pilliar RM, Arenovich T. A targeted review of study outcomes with short (≤ 7 mm) endosseous dental implants placed in partially edentulous patients. J Periodontol 2004;75:798-804.
    • (2004) J Periodontol , vol.75 , pp. 798-804
    • Hagi, D.1    Deporter, D.A.2    Pilliar, R.M.3    Arenovich, T.4
  • 5
    • 0036688398 scopus 로고    scopus 로고
    • Biologic outcome of implant-supported restorations in the treatment of partial edentulism. Part I: A longitudinal clinical evaluation
    • Naert I, Koutsikakis G, Duyck J, Quirynen M, Jacobs R, van Steenberghe D. Biologic outcome of implant-supported restorations in the treatment of partial edentulism. Part I: A longitudinal clinical evaluation. Clin Oral Implants Res 2002;13:381-389.
    • (2002) Clin Oral Implants Res , vol.13 , pp. 381-389
    • Naert, I.1    Koutsikakis, G.2    Duyck, J.3    Quirynen, M.4    Jacobs, R.5    van Steenberghe, D.6
  • 6
    • 0347418233 scopus 로고    scopus 로고
    • Clinical evaluation of short machined surface implants followed for 12 to 92 months
    • Tawil G, Younan R. Clinical evaluation of short machined surface implants followed for 12 to 92 months. Int J Oral Maxillofac Implants 2003;18:894-901.
    • (2003) Int J Oral Maxillofac Implants , vol.18 , pp. 894-901
    • Tawil, G.1    Younan, R.2
  • 7
    • 0042420609 scopus 로고    scopus 로고
    • A prospective multicenter clinical trial of 3i machined-surface implants: Results after 6 years of follow-up
    • Weng D, Jacobson Z, Tarnow D, et al. A prospective multicenter clinical trial of 3i machined-surface implants: Results after 6 years of follow-up. Int J Oral Maxillofac Implants 2003;18:417-423.
    • (2003) Int J Oral Maxillofac Implants , vol.18 , pp. 417-423
    • Weng, D.1    Jacobson, Z.2    Tarnow, D.3
  • 8
    • 0034782985 scopus 로고    scopus 로고
    • A multicenter study comparing dual acid-etched and machined-surface implants in various bone qualities
    • Khang W. A multicenter study comparing dual acid-etched and machined-surface implants in various bone qualities. J Periodontol 2001;72:1384-1390.
    • (2001) J Periodontol , vol.72 , pp. 1384-1390
    • Khang, W.1
  • 9
    • 0043014576 scopus 로고    scopus 로고
    • Early function of splinted implants in maxillas and posterior mandibles using Branemark system, machined-surface implants: An 18-month prospective clinical multicenter study
    • Bogaerde LV, Pedretti G, Dellacasa P, Mozzati M, Rangert B. Early function of splinted implants in maxillas and posterior mandibles using Branemark system, machined-surface implants: An 18-month prospective clinical multicenter study. Clin Implant Dent Relat Res 2003;5:21-28.
    • (2003) Clin Implant Dent Relat Res , vol.5 , pp. 21-28
    • Bogaerde, L.V.1    Pedretti, G.2    Dellacasa, P.3    Mozzati, M.4    Rangert, B.5
  • 10
    • 0141831255 scopus 로고    scopus 로고
    • Restoration of partially edentulous patients using dental implants with a microtextured surface: A prospective comparison of delayed and immediate full occlusal loading
    • Cannizzaro G, Leone M. Restoration of partially edentulous patients using dental implants with a microtextured surface: A prospective comparison of delayed and immediate full occlusal loading. Int J Oral Maxillofac Implants 2003;18:512-522.
    • (2003) Int J Oral Maxillofac Implants , vol.18 , pp. 512-522
    • Cannizzaro, G.1    Leone, M.2
  • 11
    • 12244272188 scopus 로고    scopus 로고
    • Early and immediately restored and loaded dental implants for single-tooth and partial-arch applications
    • Ganeles J, Wismeijer D. Early and immediately restored and loaded dental implants for single-tooth and partial-arch applications. Int J Oral Maxillofac Implants 2004;19(suppl):92-102.
    • (2004) Int J Oral Maxillofac Implants , vol.19 , Issue.SUPPL. , pp. 92-102
    • Ganeles, J.1    Wismeijer, D.2
  • 12
    • 12244252794 scopus 로고    scopus 로고
    • Immediate restoration and loading of dental implants: Clinical considerations and protocols
    • Morton D, Jaffin R, Weber H-P. Immediate restoration and loading of dental implants: Clinical considerations and protocols, Int J Oral Maxillofac Implants 2004;19(suppl):103-108.
    • (2004) Int J Oral Maxillofac Implants , vol.19 , Issue.SUPPL. , pp. 103-108
    • Morton, D.1    Jaffin, R.2    Weber, H.-P.3
  • 13
    • 12244283740 scopus 로고    scopus 로고
    • Consensus statements and recommended clinical procedures regarding loading protocols for endosseous dental implants
    • Cochran DL, Morton D, Weber H-P. Consensus statements and recommended clinical procedures regarding loading protocols for endosseous dental implants. Int J Oral Maxillofac Implants 2004;19(suppl):109-113.
    • (2004) Int J Oral Maxillofac Implants , vol.19 , Issue.SUPPL. , pp. 109-113
    • Cochran, D.L.1    Morton, D.2    Weber, H.-P.3
  • 14
    • 0035461999 scopus 로고    scopus 로고
    • Managing the posterior mandible of partially edentulous patients with short, porous-surfaced dental implants: Early data from a clinical trial
    • Deporter DA, Pilliar RM, Todescan R, Watson P, Pharoah M. Managing the posterior mandible of partially edentulous patients with short, porous-surfaced dental implants: Early data from a clinical trial. Int J Oral Maxillofac Implants 2001;16:653-658.
    • (2001) Int J Oral Maxillofac Implants , vol.16 , pp. 653-658
    • Deporter, D.A.1    Pilliar, R.M.2    Todescan, R.3    Watson, P.4    Pharoah, M.5
  • 15
    • 0036546266 scopus 로고    scopus 로고
    • Porous-surfaced dental implants in the partially edentulous maxilla: Assessment for subclinical mobility
    • Deporter DA, Todescan R, Riley N. Porous-surfaced dental implants in the partially edentulous maxilla: Assessment for subclinical mobility. Int J Periodontics Restorative Dent 2002;22:184-192.
    • (2002) Int J Periodontics Restorative Dent , vol.22 , pp. 184-192
    • Deporter, D.A.1    Todescan, R.2    Riley, N.3
  • 16
    • 0032840782 scopus 로고    scopus 로고
    • Osseointegration of sintered porous-surfaced and plasma spray-coated implants: An animal model study of early post-implantation healing response and mechanical stability
    • Simmons C, Valiquette N, Pilliar RM. Osseointegration of sintered porous-surfaced and plasma spray-coated implants: An animal model study of early post-implantation healing response and mechanical stability. J Biomed Mater Res 1999;47:127-138.
    • (1999) J Biomed Mater Res , vol.47 , pp. 127-138
    • Simmons, C.1    Valiquette, N.2    Pilliar, R.M.3
  • 17
    • 0025484812 scopus 로고
    • Dental implants: Materials and design
    • Pilliar RM. Dental implants: Materials and design. J Can Dent Assoc 1990;56:857-861.
    • (1990) J Can Dent Assoc , vol.56 , pp. 857-861
    • Pilliar, R.M.1
  • 18
    • 0025423162 scopus 로고
    • A histological comparison in the dog of porous-surfaced vs threaded dental implants
    • Deporter DA, Watson PA, Pilliar RM, Chipman M, Valiquette NA. A histological comparison in the dog of porous-surfaced vs threaded dental implants. J Dent Res 1990;69:1138-1145.
    • (1990) J Dent Res , vol.69 , pp. 1138-1145
    • Deporter, D.A.1    Watson, P.A.2    Pilliar, R.M.3    Chipman, M.4    Valiquette, N.A.5
  • 19
    • 0028509555 scopus 로고
    • Predictable crestal bone remodeling around two porous-surfaced titanium alloy dental implant designs. A radiographic study in dogs
    • Al-Sayyed A, Deporter DA, Pilliar RM, et al. Predictable crestal bone remodeling around two porous-surfaced titanium alloy dental implant designs. A radiographic study in dogs. Clin Oral Implants Res 1994;5:131-141.
    • (1994) Clin Oral Implants Res , vol.5 , pp. 131-141
    • Al-Sayyed, A.1    Deporter, D.A.2    Pilliar, R.M.3
  • 20
    • 0043014576 scopus 로고    scopus 로고
    • Early function of splinted implants in maxillas and posterior mandibles using Branemark system machined-surface implants: An 18-month prospective clinical multicenter study
    • Bogaerde LV, Pedretti G, Dellacasa P, Mozzati M, Rangert B. Early function of splinted implants in maxillas and posterior mandibles using Branemark system machined-surface implants: An 18-month prospective clinical multicenter study. Clin Implant Dent Relat Res 2003;5(suppl):21-28.
    • (2003) Clin Implant Dent Relat Res , vol.5 , Issue.SUPPL. , pp. 21-28
    • Bogaerde, L.V.1    Pedretti, G.2    Dellacasa, P.3    Mozzati, M.4    Rangert, B.5
  • 21
    • 21344442647 scopus 로고    scopus 로고
    • Immediate and early loading of SLA ITI single-tooth implants: An in vivo study
    • Quinlan P, Nummikoski P, Schenk R, et al. Immediate and early loading of SLA ITI single-tooth implants: An in vivo study. Int J Oral Maxillofac Implants 2005;20:360-371.
    • (2005) Int J Oral Maxillofac Implants , vol.20 , pp. 360-371
    • Quinlan, P.1    Nummikoski, P.2    Schenk, R.3
  • 22
    • 0041511733 scopus 로고    scopus 로고
    • Immediate loading in the maxilla using flapless surgery, implants placed in predetermined positions and prefabricated provisional restorations: A retrospective 3-year clinical study
    • Rocci A, Martignoni M, Gottlow J. Immediate loading in the maxilla using flapless surgery, implants placed in predetermined positions and prefabricated provisional restorations: A retrospective 3-year clinical study. Clin Implant Dent Rel Res 2003;5(suppl):29-36.
    • (2003) Clin Implant Dent Rel Res , vol.5 , Issue.SUPPL. , pp. 29-36
    • Rocci, A.1    Martignoni, M.2    Gottlow, J.3
  • 23
    • 3042577848 scopus 로고    scopus 로고
    • Immediate occlusal loading of Osseotite implants in the lower edentulous jaw. A multicenter prospective study
    • Testori T, Meltzer A, Del Fabbro M, et al. Immediate occlusal loading of Osseotite implants in the lower edentulous jaw. A multicenter prospective study. Clin Oral Implants Res 2004;15:278-284.
    • (2004) Clin Oral Implants Res , vol.15 , pp. 278-284
    • Testori, T.1    Meltzer, A.2    Del Fabbro, M.3
  • 24
    • 0345227292 scopus 로고    scopus 로고
    • Immediate/early loading of oral implants in compromised patients
    • Lekholm U. Immediate/early loading of oral implants in compromised patients. Periodontology 2000 2003;33:194-203.
    • (2003) Periodontology 2000 , vol.33 , pp. 194-203
    • Lekholm, U.1
  • 25
    • 15944387744 scopus 로고    scopus 로고
    • A prospective study of immediate functional loading following the Teeth in a Day protocol. A case series of 55 consecutive edentulous maxillae
    • Balshi S, Wolfinger G, Balshi T. A prospective study of immediate functional loading following the Teeth in a Day protocol. A case series of 55 consecutive edentulous maxillae. Clin Implant Dent Relat Res 2005;7:24-31.
    • (2005) Clin Implant Dent Relat Res , vol.7 , pp. 24-31
    • Balshi, S.1    Wolfinger, G.2    Balshi, T.3
  • 27
    • 0022413393 scopus 로고    scopus 로고
    • The influence of induced micromovement upon the healing of experimental tibial fractures
    • Goodship AE, Kenwright J. The influence of induced micromovement upon the healing of experimental tibial fractures. J Bone Joint Surg 1095;676:650-655.
    • J Bone Joint Surg , vol.1095 , Issue.676 , pp. 650-655
    • Goodship, A.E.1    Kenwright, J.2
  • 28
    • 0035062762 scopus 로고    scopus 로고
    • Differences in osseointegration rate due to implant surface geometry can be explained by local tissue strains
    • Simmons CA, Meguid SA, Pilliar RM. Differences in osseointegration rate due to implant surface geometry can be explained by local tissue strains. J Orthop Res 2001;19:187-194.
    • (2001) J Orthop Res , vol.19 , pp. 187-194
    • Simmons, C.A.1    Meguid, S.A.2    Pilliar, R.M.3
  • 29
    • 0022465758 scopus 로고
    • Observations on the effect of movement on bone ingrowth into porous-surfaced implants
    • Pilliar RM, Lee JM, Maniatopoulos C. Observations on the effect of movement on bone ingrowth into porous-surfaced implants. Clin Orthop Relat Res 1986:208:108-113.
    • (1986) Clin Orthop Relat Res , vol.208 , pp. 108-113
    • Pilliar, R.M.1    Lee, J.M.2    Maniatopoulos, C.3
  • 31
    • 0029415087 scopus 로고
    • Finite element analysis of crestal bone loss around porous-coated dental implants
    • Vaillancourt H, Pilliar RM, McCammond D. Finite element analysis of crestal bone loss around porous-coated dental implants, J Appl Biomater 1995;6:267-282.
    • (1995) J Appl Biomater , vol.6 , pp. 267-282
    • Vaillancourt, H.1    Pilliar, R.M.2    McCammond, D.3
  • 32
    • 0030224033 scopus 로고    scopus 로고
    • The peri-implant hard and soft tissues at different implant systems. A comparative study in the dog
    • Abrahamsson I. The peri-implant hard and soft tissues at different implant systems. A comparative study in the dog. Clin Oral Implants Res 1996;7:212-219.
    • (1996) Clin Oral Implants Res , vol.7 , pp. 212-219
    • Abrahamsson, I.1
  • 33
    • 0030253561 scopus 로고    scopus 로고
    • Dimension of the peri-implant mucosa. Biologic width revisited
    • Berglundh T, Lindhe J. Dimension of the peri-implant mucosa. Biologic width revisited. J Clin Periodont 1996;23:971-973.
    • (1996) J Clin Periodont , vol.23 , pp. 971-973
    • Berglundh, T.1    Lindhe, J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.