메뉴 건너뛰기




Volumn 64, Issue 1, 2008, Pages 111-114

Needle thoracostomy in the treatment of a tension pneumothorax in trauma patients: What size needle?

Author keywords

Chest wall thickness; Computed tomography; Needle thoracostomy; Tension pneumothorax

Indexed keywords

ADULT; ARTICLE; CATHETER; COMPUTER ASSISTED TOMOGRAPHY; FEMALE; HUMAN; INJURY SEVERITY; MAJOR CLINICAL STUDY; MALE; NEEDLE; PNEUMOTHORAX; PRIORITY JOURNAL; RETROSPECTIVE STUDY; STATISTICAL ANALYSIS; SURGICAL TECHNIQUE; TENSION PNEUMOTHORAX; THORAX DRAINAGE; TREATMENT FAILURE;

EID: 38149075217     PISSN: 00225282     EISSN: 15298809     Source Type: Journal    
DOI: 10.1097/01.ta.0000239241.59283.03     Document Type: Article
Times cited : (89)

References (24)
  • 2
    • 12344292854 scopus 로고    scopus 로고
    • Tension pneumothorax-time for a re-think?
    • Leigh-Smith S, Harris T. Tension pneumothorax-time for a re-think? Emerg Med J. 2005;22:8-16.
    • (2005) Emerg Med J , vol.22 , pp. 8-16
    • Leigh-Smith, S.1    Harris, T.2
  • 3
  • 4
    • 38149070209 scopus 로고    scopus 로고
    • American College of Surgeons, Committee on Trauma. Advanced Trauma Life Support Course Manual. Chicago, IL: ACSCOT; 2004; 105:127.
    • American College of Surgeons, Committee on Trauma. Advanced Trauma Life Support Course Manual. Chicago, IL: ACSCOT; 2004; 105:127.
  • 5
    • 0033985626 scopus 로고    scopus 로고
    • Prehospital recognition of tension pneumothorax
    • Friend KD. Prehospital recognition of tension pneumothorax. Prehosp Emerg Care. 2000;4:75-77.
    • (2000) Prehosp Emerg Care , vol.4 , pp. 75-77
    • Friend, K.D.1
  • 6
    • 0028970227 scopus 로고
    • Prehospital needle aspiration and tube thoracostomy in trauma victims: A six-year experience with aeromedical crews
    • Barton ED, Epperson M, Hoyt DB, Fortlage D, Rosen P. Prehospital needle aspiration and tube thoracostomy in trauma victims: a six-year experience with aeromedical crews. J Emerg Med. 1995;13:155-163.
    • (1995) J Emerg Med , vol.13 , pp. 155-163
    • Barton, E.D.1    Epperson, M.2    Hoyt, D.B.3    Fortlage, D.4    Rosen, P.5
  • 7
    • 26044444224 scopus 로고    scopus 로고
    • The safety and efficacy of prehospital needle and tube thoracostomy by aeromedical personnel
    • Davis DP, Pettit K, Rom CD, et al. The safety and efficacy of prehospital needle and tube thoracostomy by aeromedical personnel. Prehosp Emerg Care. 2005;9:191-197.
    • (2005) Prehosp Emerg Care , vol.9 , pp. 191-197
    • Davis, D.P.1    Pettit, K.2    Rom, C.D.3
  • 8
    • 3042829829 scopus 로고    scopus 로고
    • Complications of intercostal catheter insertion using EMST techniques for chest trauma
    • Heng K, Bystrzycki A, Fitzgerald M, et al. Complications of intercostal catheter insertion using EMST techniques for chest trauma. ANZ J Surg. 2004;74:420-423.
    • (2004) ANZ J Surg , vol.74 , pp. 420-423
    • Heng, K.1    Bystrzycki, A.2    Fitzgerald, M.3
  • 9
    • 0029855243 scopus 로고    scopus 로고
    • Chest wall thickness may limit adequate drainage of tension pneumothorax by needle thoracocentesis
    • Britten S, Palmer SH. Chest wall thickness may limit adequate drainage of tension pneumothorax by needle thoracocentesis. J Accid Emerg Med. 1996;13:426-427.
    • (1996) J Accid Emerg Med , vol.13 , pp. 426-427
    • Britten, S.1    Palmer, S.H.2
  • 10
    • 0030435972 scopus 로고    scopus 로고
    • Needle thoracocentesis in tension pneumothorax: Insufficient cannula length and potential failure
    • Pattison GT. Needle thoracocentesis in tension pneumothorax: insufficient cannula length and potential failure. Injury. 1996;27:758.
    • (1996) Injury , vol.27 , pp. 758
    • Pattison, G.T.1
  • 11
    • 0036205782 scopus 로고    scopus 로고
    • Tension pneumothoraces not responding to needle thoracocentesis
    • Jones R, Hollingsworth J. Tension pneumothoraces not responding to needle thoracocentesis. Emerg Med J. 2002;19:176-177.
    • (2002) Emerg Med J , vol.19 , pp. 176-177
    • Jones, R.1    Hollingsworth, J.2
  • 12
    • 0033817579 scopus 로고    scopus 로고
    • Needle thoracocentesis fails to diagnose a large pneumothorax
    • Jenkins C, Sudheer PS. Needle thoracocentesis fails to diagnose a large pneumothorax. Anaesthesia. 2000;55:925-926.
    • (2000) Anaesthesia , vol.55 , pp. 925-926
    • Jenkins, C.1    Sudheer, P.S.2
  • 13
    • 0029953761 scopus 로고    scopus 로고
    • Needle thoracocentesis in tension pneumothorax: Insufficient cannula length and potential failure
    • Britten S, Palmer SH, Snow TM. Needle thoracocentesis in tension pneumothorax: insufficient cannula length and potential failure. Injury. 1996;27:321-322.
    • (1996) Injury , vol.27 , pp. 321-322
    • Britten, S.1    Palmer, S.H.2    Snow, T.M.3
  • 14
    • 0842282696 scopus 로고    scopus 로고
    • Needle thoracostomy: Implications of computed tomography chest wall thickness [see comment]
    • Givens ML, Ayotte K, Manifold C. Needle thoracostomy: implications of computed tomography chest wall thickness [see comment]. Acad Emerg Med. 2004;11:211-213.
    • (2004) Acad Emerg Med , vol.11 , pp. 211-213
    • Givens, M.L.1    Ayotte, K.2    Manifold, C.3
  • 15
    • 12344287472 scopus 로고    scopus 로고
    • Needle thoracostomy in trauma patients: What catheter length is adequate?
    • Marinaro J, Kenny CV, Smith SR, et al. Needle thoracostomy in trauma patients: what catheter length is adequate? Acad Emerg Med. 2003;10:495.
    • (2003) Acad Emerg Med , vol.10 , pp. 495
    • Marinaro, J.1    Kenny, C.V.2    Smith, S.R.3
  • 16
    • 0027273537 scopus 로고
    • Needle thoracostomy fails to detect a fatal tension pneumothorax
    • Mines D, Abbuhl S. Needle thoracostomy fails to detect a fatal tension pneumothorax. Ann Emerg Med. 1993;22:863-866.
    • (1993) Ann Emerg Med , vol.22 , pp. 863-866
    • Mines, D.1    Abbuhl, S.2
  • 17
    • 0028089254 scopus 로고
    • Post-mortem limitations of body composition analysis by computed tomography
    • Janssens V, Thys P, Clarys JP, et al. Post-mortem limitations of body composition analysis by computed tomography. Ergonomics. 1994;37:207-216.
    • (1994) Ergonomics , vol.37 , pp. 207-216
    • Janssens, V.1    Thys, P.2    Clarys, J.P.3
  • 18
    • 0031829972 scopus 로고    scopus 로고
    • Cadaver validation of skeletal muscle measurement by magnetic resonance imaging and computerized tomography
    • Mitsiopoulos N, Baumgartner RN, Heymsfield SB, et al. Cadaver validation of skeletal muscle measurement by magnetic resonance imaging and computerized tomography. J Appl Physiol. 1998;85:115-122.
    • (1998) J Appl Physiol , vol.85 , pp. 115-122
    • Mitsiopoulos, N.1    Baumgartner, R.N.2    Heymsfield, S.B.3
  • 19
    • 3142706018 scopus 로고    scopus 로고
    • Virtual anatomical three-dimensional fit trial for intra-thoracically implanted medical devices
    • Warriner RK, Haddad M, Hendry PJ, Mussivand T. Virtual anatomical three-dimensional fit trial for intra-thoracically implanted medical devices. ASAIO J. 2004;50:354-359.
    • (2004) ASAIO J , vol.50 , pp. 354-359
    • Warriner, R.K.1    Haddad, M.2    Hendry, P.J.3    Mussivand, T.4
  • 20
    • 0037349376 scopus 로고    scopus 로고
    • Pulmonary artery injury and cardiac tamponade after needle decompression of a suspected tension pneumothorax
    • Butler KL, Best IM, Weaver WL, Bumpers HL. Pulmonary artery injury and cardiac tamponade after needle decompression of a suspected tension pneumothorax. J Trauma. 2003;54:610-611.
    • (2003) J Trauma , vol.54 , pp. 610-611
    • Butler, K.L.1    Best, I.M.2    Weaver, W.L.3    Bumpers, H.L.4
  • 21
    • 0036848569 scopus 로고    scopus 로고
    • Use of the Asherman chest seal as a stabilisation device for needle thoracostomy
    • Allison K, Porter KM, Mason AM. Use of the Asherman chest seal as a stabilisation device for needle thoracostomy. Emerg Med J. 2002;19:590-591.
    • (2002) Emerg Med J , vol.19 , pp. 590-591
    • Allison, K.1    Porter, K.M.2    Mason, A.M.3
  • 22
    • 85077805679 scopus 로고    scopus 로고
    • Needle thoracostomy: A cautionary note [comment]
    • Biffl WL. Needle thoracostomy: a cautionary note [comment]. Acad Emerg Med. 2004;11:795-796.
    • (2004) Acad Emerg Med , vol.11 , pp. 795-796
    • Biffl, W.L.1
  • 23
    • 0037622891 scopus 로고    scopus 로고
    • Life threatening haemorrhage after anterior needle aspiration of pneumothoraces. A role for lateral needle aspiration in emergency decompression of spontaneous pneumothorax. [comment]
    • Rawlins R, Brown KM, Carr CS, Cameron CR. Life threatening haemorrhage after anterior needle aspiration of pneumothoraces. A role for lateral needle aspiration in emergency decompression of spontaneous pneumothorax. [comment]. Emerg Med J. 2003;20:383-384.
    • (2003) Emerg Med J , vol.20 , pp. 383-384
    • Rawlins, R.1    Brown, K.M.2    Carr, C.S.3    Cameron, C.R.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.