Volumn 58, Issue 5, 2007, Pages 286-291

Detection of suspicious malignant cervical lymph nodes of unknown origin: Diagnostic accuracy of ultrasound-guided fine-needle aspiration biopsy with nodal size and central necrosis correlate

Author keywords

Fine needle aspiration; Lymph node; Malignancy; Neck; Ultrasound guided biopsy

Indexed keywords

ADOLESCENT; ADULT; AGED; ARTICLE; ASPIRATION BIOPSY; CANCER SIZE; CERVICAL LYMPH NODE; CLINICAL ASSESSMENT; CLINICAL EVALUATION; COMPUTER ASSISTED TOMOGRAPHY; DIAGNOSTIC ACCURACY; ECHOGRAPHY; FEMALE; FOLLOW UP; HUMAN; HUMAN TISSUE; IDIOPATHIC DISEASE; LYMPHADENITIS; LYMPHOMA; MAJOR CLINICAL STUDY; MALE; NECK TUMOR; NUCLEAR MAGNETIC RESONANCE IMAGING; SCHOOL CHILD; SENSITIVITY AND SPECIFICITY;

EID: 38149063479     PISSN: 08465371     EISSN: 08465371     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (14)

References (14)
  • 1
    • 0025783871 scopus 로고
    • Occult metastatic neck disease: Detection with US and US-guided fine-needle aspiration cytology
    • van den Brekel MWM, Castelijns JA, Stel HV, et al. Occult metastatic neck disease: detection with US and US-guided fine-needle aspiration cytology. Radiology. 1991;180:457-461.
    • (1991) Radiology , vol.180 , pp. 457-461
    • van den Brekel, M.W.M.1    Castelijns, J.A.2    Stel, H.V.3
  • 2
    • 0027412611 scopus 로고
    • Modern imaging techniques and ultrasound-guided aspiration cytology for the assessment of neck node metastases: A prospective comparative study
    • van den Brekel MWM, Castelijns JA, Stel HV, et al. Modern imaging techniques and ultrasound-guided aspiration cytology for the assessment of neck node metastases: a prospective comparative study. Eur Arch Otorhinolaryngol. 1993;250:11-17.
    • (1993) Eur Arch Otorhinolaryngol , vol.250 , pp. 11-17
    • van den Brekel, M.W.M.1    Castelijns, J.A.2    Stel, H.V.3
  • 3
    • 13344269680 scopus 로고    scopus 로고
    • Regional metastasis in head and neck squamous cell carcinoma: Revised value of US with US-guided FNAB
    • Takes RP, Knegt P, Manni JJ, et al. Regional metastasis in head and neck squamous cell carcinoma: revised value of US with US-guided FNAB. Radiology. 1996;198:819-823.
    • (1996) Radiology , vol.198 , pp. 819-823
    • Takes, R.P.1    Knegt, P.2    Manni, J.J.3
  • 4
    • 0030978562 scopus 로고    scopus 로고
    • Nonpalpable lymph nodes of the neck: Assessment with US and US-guided fine-needle aspiration biopsy
    • Takashima S, Sone S, Noruma N, et al. Nonpalpable lymph nodes of the neck: assessment with US and US-guided fine-needle aspiration biopsy. J Clin Ultrasound. 1997;25(6):283-292.
    • (1997) J Clin Ultrasound , vol.25 , Issue.6 , pp. 283-292
    • Takashima, S.1    Sone, S.2    Noruma, N.3
  • 5
    • 0033811492 scopus 로고    scopus 로고
    • Ultrasonography-guided fine-needle aspiration for the assessment of cervical metastases
    • Knappe M, Louw M, Gregor RT. Ultrasonography-guided fine-needle aspiration for the assessment of cervical metastases. Arch Otolaryngol Head Neck Surg. 2000;126:1091-1096.
    • (2000) Arch Otolaryngol Head Neck Surg , vol.126 , pp. 1091-1096
    • Knappe, M.1    Louw, M.2    Gregor, R.T.3
  • 6
    • 0031239516 scopus 로고    scopus 로고
    • Assessment of cervical lymph node status in head and neck cancer patients: Palpation, computed tomography and low field magnetic resonance imaging compared with ultrasound-guided fine-needle aspiration cytology
    • Atula TS, Matti JV, Kurki TJ, et al. Assessment of cervical lymph node status in head and neck cancer patients: palpation, computed tomography and low field magnetic resonance imaging compared with ultrasound-guided fine-needle aspiration cytology. Eur J Radiol. 1997;25:152-161.
    • (1997) Eur J Radiol , vol.25 , pp. 152-161
    • Atula, T.S.1    Matti, J.V.2    Kurki, T.J.3
  • 7
    • 0030886134 scopus 로고    scopus 로고
    • Comparison of ultrasound: Fine needle aspiration and computed tomography in patients undergoing elective neck dissection
    • Righi PD, Kopecky KK, Caldemeyer KS, et al. Comparison of ultrasound: fine needle aspiration and computed tomography in patients undergoing elective neck dissection. Head Neck. 1997;19:604-610.
    • (1997) Head Neck , vol.19 , pp. 604-610
    • Righi, P.D.1    Kopecky, K.K.2    Caldemeyer, K.S.3
  • 9
    • 0024990422 scopus 로고
    • Cervical lymph node metastases: Assessment of radiologic criteria
    • van den Brekel MWM, Stel HV, Castelijns JA, et al. Cervical lymph node metastases: assessment of radiologic criteria. Radiology. 1990;177:379-384.
    • (1990) Radiology , vol.177 , pp. 379-384
    • van den Brekel, M.W.M.1    Stel, H.V.2    Castelijns, J.A.3
  • 10
    • 0026507824 scopus 로고
    • Differentiation of benign from malignant superficial lymphadenopathy: The role of high-resolution US
    • Vassallo P, Wernecke K, Roos N, et al. Differentiation of benign from malignant superficial lymphadenopathy: the role of high-resolution US. Radiology. 1992;183:215-220.
    • (1992) Radiology , vol.183 , pp. 215-220
    • Vassallo, P.1    Wernecke, K.2    Roos, N.3
  • 11
    • 2942681696 scopus 로고    scopus 로고
    • Lymph node
    • Som PM, Curtin HD, editors, 4th ed. St Louis MO, Mosby;
    • Som PM, Brandwein MS. Lymph node. In: Som PM, Curtin HD, editors. Head and neck imaging. 4th ed. St Louis (MO): Mosby; 2003. p 1865.
    • (2003) Head and neck imaging , pp. 1865
    • Som, P.M.1    Brandwein, M.S.2
  • 12
    • 0032231741 scopus 로고    scopus 로고
    • The size of lymph nodes in the neck on sonograms as a radiologic criterion for metastasis: How reliable is it?
    • van den Brekel MWM, Castelijns JA, Snow GB. The size of lymph nodes in the neck on sonograms as a radiologic criterion for metastasis: how reliable is it? AJNR Am J Neuroradiol. 1998;19:695-700.
    • (1998) AJNR Am J Neuroradiol , vol.19 , pp. 695-700
    • van den Brekel, M.W.M.1    Castelijns, J.A.2    Snow, G.B.3
  • 13
    • 1342266168 scopus 로고    scopus 로고
    • Necrosis in metastatic neck nodes: Diagnostic accuracy of CT, MR imaging, and US
    • King AD, Tse GM, Ahuja AT, et al. Necrosis in metastatic neck nodes: diagnostic accuracy of CT, MR imaging, and US. Radiology. 2004;230:720-726.
    • (2004) Radiology , vol.230 , pp. 720-726
    • King, A.D.1    Tse, G.M.2    Ahuja, A.T.3
  • 14
    • 0033994320 scopus 로고    scopus 로고
    • Imaging-based nodal classification for evaluation of neck metastatic adenopathy
    • Som PM, Curtin HD, Mancuso AA. Imaging-based nodal classification for evaluation of neck metastatic adenopathy. AJR. 2000;174:837-844.
    • (2000) AJR , vol.174 , pp. 837-844
    • Som, P.M.1    Curtin, H.D.2    Mancuso, A.A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.