메뉴 건너뛰기




Volumn 33, Issue , 2006, Pages 125-128

A framework for real-time left ventricular tracking in 3D+T echocardiography, using nonlinear deformable contours and Kalman filter based tracking

Author keywords

[No Author keywords available]

Indexed keywords

BIOMECHANICS; CARDIOLOGY; CELLULAR RADIO SYSTEMS; CONTROL THEORY; DEFORMATION; ECHOCARDIOGRAPHY; KALMAN FILTERS; MATHEMATICAL MODELS; TRACKING (POSITION); WAVE FILTERS;

EID: 38149027395     PISSN: 02766574     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (15)

References (11)
  • 2
    • 0027676791 scopus 로고
    • A framework for spatiotemporal control in the tracking of visual contours
    • Blake A, Curwen R, Zisserman A. A framework for spatiotemporal control in the tracking of visual contours. International Journal of Computer Vision 1993;11(2):127-145.
    • (1993) International Journal of Computer Vision , vol.11 , Issue.2 , pp. 127-145
    • Blake, A.1    Curwen, R.2    Zisserman, A.3
  • 3
    • 0029389983 scopus 로고
    • Learning to track the visual motion of contours
    • Blake A, Isard M, Reynard D. Learning to track the visual motion of contours. Artificial Intelligence 1995;78(1-2):179-212.
    • (1995) Artificial Intelligence , vol.78 , Issue.1-2 , pp. 179-212
    • Blake, A.1    Isard, M.2    Reynard, D.3
  • 4
    • 0004269916 scopus 로고    scopus 로고
    • Secaucus, NJ, USA: Springer-Verlag New York, Inc, ISBN 3540762175
    • Blake A, Isard M. Active Contours. Secaucus, NJ, USA: Springer-Verlag New York, Inc., 1998. ISBN 3540762175.
    • (1998) Active Contours
    • Blake, A.1    Isard, M.2
  • 5
    • 0033084875 scopus 로고    scopus 로고
    • Evaluating a robust contour tracker on echocardiographic sequences
    • Jacob G, Noble JA, Mulet-Parada M, Blake A. Evaluating a robust contour tracker on echocardiographic sequences. Medical Image Analysis 1999;3(1):63-75.
    • (1999) Medical Image Analysis , vol.3 , Issue.1 , pp. 63-75
    • Jacob, G.1    Noble, J.A.2    Mulet-Parada, M.3    Blake, A.4
  • 7
    • 0036489380 scopus 로고    scopus 로고
    • A shape-space based approach to tracking myocardial borders and quantifying regional left ventricular function applied in echocardiography
    • Jacob G, Noble JA, Behrenbruch CP, Kelion AD, Banning AP. A shape-space based approach to tracking myocardial borders and quantifying regional left ventricular function applied in echocardiography. IEEE Transactions on Medical Imaging 2002;21(3):226-238.
    • (2002) IEEE Transactions on Medical Imaging , vol.21 , Issue.3 , pp. 226-238
    • Jacob, G.1    Noble, J.A.2    Behrenbruch, C.P.3    Kelion, A.D.4    Banning, A.P.5
  • 9
    • 0030173761 scopus 로고    scopus 로고
    • Deformable models with parameter functions for cardiac motion analysis from tagged mri data
    • June
    • Park J, Metaxas D, Young A, Axel L. Deformable models with parameter functions for cardiac motion analysis from tagged mri data. IEEE Transactions on Medical Imaging June 1996;15(3):290-298.
    • (1996) IEEE Transactions on Medical Imaging , vol.15 , Issue.3 , pp. 290-298
    • Park, J.1    Metaxas, D.2    Young, A.3    Axel, L.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.