메뉴 건너뛰기




Volumn 19, Issue 4, 2007, Pages 213-222

Examination of reliability and validity of walking speed, cadence, stride length - Comparison of measurement with stopwatch and three-dimension motion analyzer -

Author keywords

Gait analysis; Inter tester reliability; Measurement time method

Indexed keywords


EID: 38049181271     PISSN: 09155287     EISSN: None     Source Type: Journal    
DOI: 10.1589/jpts.19.213     Document Type: Article
Times cited : (5)

References (13)
  • 1
    • 38049169346 scopus 로고    scopus 로고
    • Morohashi I, Handa T: Maximmn walking speed. In: Handbook of Clinical Assesment Index. Uchiyama Y, Kobayashi T, Shiomi T (eds.), Tokyo: Kyodo-isho, 2003, pp 127-133.
    • Morohashi I, Handa T: Maximmn walking speed. In: Handbook of Clinical Assesment Index. Uchiyama Y, Kobayashi T, Shiomi T (eds.), Tokyo: Kyodo-isho, 2003, pp 127-133.
  • 2
    • 38049110596 scopus 로고    scopus 로고
    • Senjyu H: 6-minute walking distance. In: Handbook of Clinical Assessment Index. Uchiyama Y, Kobayashi T, Shiomi T (eds.), Tokyo: Kyodo-isho, 2003, pp 135-141.
    • Senjyu H: 6-minute walking distance. In: Handbook of Clinical Assessment Index. Uchiyama Y, Kobayashi T, Shiomi T (eds.), Tokyo: Kyodo-isho, 2003, pp 135-141.
  • 3
    • 38049101021 scopus 로고    scopus 로고
    • Kuge N: Physiological cost index (PCI). In: Handbook of Clinical Assesment Index. Uchiyama Y, Kobayashi T, Shiomi T (eds.), Tokyo: Kyodo-isho, 2003, pp 143-148.
    • Kuge N: Physiological cost index (PCI). In: Handbook of Clinical Assesment Index. Uchiyama Y, Kobayashi T, Shiomi T (eds.), Tokyo: Kyodo-isho, 2003, pp 143-148.
  • 5
    • 38049101020 scopus 로고
    • Walking capacity and activities of daily living in stroke paitients at community
    • Sajiki N, Nakamura R, Hosokawa T: Walking capacity and activities of daily living in stroke paitients at community. Reha Igaku, 1989, 26: 341-342.
    • (1989) Reha Igaku , vol.26 , pp. 341-342
    • Sajiki, N.1    Nakamura, R.2    Hosokawa, T.3
  • 6
    • 0023091735 scopus 로고
    • Walking cycle after stroke; Measurement and recovery over the first 3 months
    • Wade DT, Wood VA, Heller A, et al.: Walking cycle after stroke; Measurement and recovery over the first 3 months. Scnnd J Rehab Med, 1987, 191: 25-30.
    • (1987) Scnnd J Rehab Med , vol.191 , pp. 25-30
    • Wade, D.T.1    Wood, V.A.2    Heller, A.3
  • 7
    • 0029950238 scopus 로고    scopus 로고
    • Reliability and validity of measures obtained from stroke patients the Balance Master
    • Liston RA, Brouwer BJ: Reliability and validity of measures obtained from stroke patients the Balance Master. Arch Phys Med Rehabil, 1996, 77: 425-430.
    • (1996) Arch Phys Med Rehabil , vol.77 , pp. 425-430
    • Liston, R.A.1    Brouwer, B.J.2
  • 8
    • 0031003481 scopus 로고    scopus 로고
    • Confortable and maximum walking speed of adults aged 20-79 years: Reference values and determinants
    • Bohannon RW: Confortable and maximum walking speed of adults aged 20-79 years: reference values and determinants. Age Ageing, 1997, 26: 115-119.
    • (1997) Age Ageing , vol.26 , pp. 115-119
    • Bohannon, R.W.1
  • 9
    • 0030760125 scopus 로고    scopus 로고
    • Reliabilitv of gait measurements in people with osteoarthritis of the knee
    • Fransen M, Crosbie J, Edmonds J: Reliabilitv of gait measurements in people with osteoarthritis of the knee. Phys Ther, 1997, 77: 944-953.
    • (1997) Phys Ther , vol.77 , pp. 944-953
    • Fransen, M.1    Crosbie, J.2    Edmonds, J.3
  • 10
    • 38049103585 scopus 로고    scopus 로고
    • 3D Motion Analyzer/Force Plate-Handbook of Measurment
    • Uchiyama Y, Kobayashi T, Maze N eds
    • Uchiyama Y, Kobayashi T, Maze N (eds.): 3D Motion Analyzer/Force Plate-Handbook of Measurment. Tokyo: Kyodo-isho, 2001. pp 160-170.
    • (2001) Tokyo: Kyodo-isho , pp. 160-170