Use of an amorphous silicon EPID for measuring MLC calibration at varying gantry angle

Author keywords

[No Author keywords available]

Indexed keywords

AMORPHOUS SILICON; OPTICAL COLLIMATORS; PATIENT TREATMENT; PIXELS; PORTALS; QUALITY CONTROL;

EID: 38049169060     PISSN: 00319155     EISSN: 13616560     Source Type: Journal    
DOI: 10.1088/0031-9155/53/2/013     Document Type: Article
Times cited : (36)

References (25)
  • 1
    • 17144426504 scopus 로고    scopus 로고
    • Use of an amorphous silicon electronic portal imaging device for multileaf collimator quality control and calibration
    • Baker S J K, Budgell G J and MacKay R I 2005 Use of an amorphous silicon electronic portal imaging device for multileaf collimator quality control and calibration Phys. Med. Biol. 50 1377-92
    • (2005) Phys. Med. Biol. , vol.50 , Issue.7 , pp. 1377-1392
    • Baker, S.J.K.1    Budgell, G.J.2    MacKay, R.I.3
  • 2
    • 0034083357 scopus 로고    scopus 로고
    • Requirements for leaf position accuracy for dynamic multileaf collimation
    • Budgell G J, Mott J H L, Williams P C and Brown K J 2000 Requirements for leaf position accuracy for dynamic multileaf collimation Phys. Med. Biol. 45 1211-227
    • (2000) Phys. Med. Biol. , vol.45 , Issue.5 , pp. 1211-1227
    • Budgell, G.J.1    Mott, J.H.L.2    Williams, P.C.3    Brown, K.J.4
  • 3
    • 17844380035 scopus 로고    scopus 로고
    • Accurate technique for complete geometric calibration of cone-beam computed tomography systems
    • Cho Y, Moseley D J, Siewerdsen J H and Jaffray D A 2005 Accurate technique for complete geometric calibration of cone-beam computed tomography systems Med. Phys. 32 968-83
    • (2005) Med. Phys. , vol.32 , Issue.4 , pp. 968-983
    • Cho, Y.1    Moseley, D.J.2    Siewerdsen, J.H.3    Jaffray, D.A.4
  • 4
    • 0029072349 scopus 로고
    • Treatment delivery accuracy in intensity-modulated conformal radiotherapy
    • Convery D J and Rosenbloom M E 1995 Treatment delivery accuracy in intensity-modulated conformal radiotherapy Phys. Med. Biol. 40 979-99
    • (1995) Phys. Med. Biol. , vol.40 , Issue.6 , pp. 979-999
    • Convery, D.J.1    Rosenbloom, M.E.2
  • 5
    • 0034505460 scopus 로고    scopus 로고
    • Testing of the stability of intensity modulated beams generated with dynamic multileaf collimation, applied to the MM50 racetrack microtron
    • Dirkx M L and Heijmen B J 2000 Testing of the stability of intensity modulated beams generated with dynamic multileaf collimation, applied to the MM50 racetrack microtron Med. Phys. 27 2701-7
    • (2000) Med. Phys. , vol.27 , Issue.12 , pp. 2701-2707
    • Dirkx, M.L.1    Heijmen, B.J.2
  • 7
    • 0033965317 scopus 로고    scopus 로고
    • Verification of dynamic multileaf collimation using an electronic portal imaging device
    • James H V, Atherton S, Budgell G J, Kirby M C and Williams P C 2000 Verification of dynamic multileaf collimation using an electronic portal imaging device Phys. Med. Biol. 45 495-509
    • (2000) Phys. Med. Biol. , vol.45 , Issue.2 , pp. 495-509
    • James, H.V.1    Atherton, S.2    Budgell, G.J.3    Kirby, M.C.4    Williams, P.C.5
  • 8
    • 0028346915 scopus 로고
    • The design and performance characteristics of a multileaf collimator
    • Jordan T J and Williams P C 1994 The design and performance characteristics of a multileaf collimator Phys. Med. Biol. 39 231-51
    • (1994) Phys. Med. Biol. , vol.39 , Issue.2 , pp. 231-251
    • Jordan, T.J.1    Williams, P.C.2
  • 9
    • 0027141513 scopus 로고
    • Measurement possibilities using an electronic portal imaging device
    • Kirby M C and Williams P C 1993 Measurement possibilities using an electronic portal imaging device Radiother. Oncol. 29 237-43
    • (1993) Radiother. Oncol. , vol.29 , Issue.2 , pp. 237-243
    • Kirby, M.C.1    Williams, P.C.2
  • 10
    • 0028851403 scopus 로고
    • A multipurpose phantom for use with electronic portal imaging devices
    • Kirby M C 1995 A multipurpose phantom for use with electronic portal imaging devices Phys. Med. Biol. 40 323-34
    • (1995) Phys. Med. Biol. , vol.40 , Issue.2 , pp. 323-334
    • Kirby, M.C.1
  • 11
    • 34247487540 scopus 로고    scopus 로고
    • Evaluation of MLC leaf positioning using a scanning liquid ionization chamber EPID
    • Mohammadi M and Bezak E 2007 Evaluation of MLC leaf positioning using a scanning liquid ionization chamber EPID Phys. Med. Biol. 52 N21-33
    • (2007) Phys. Med. Biol. , vol.52 , Issue.1
    • Mohammadi, M.1    Bezak, E.2
  • 12
    • 33748312239 scopus 로고    scopus 로고
    • Evaluation of two methods of predicting MLC leaf positions using EPID measurements
    • Parent L, Seco J, Evans P M, Dance D R and Fielding A 2006 Evaluation of two methods of predicting MLC leaf positions using EPID measurements Med. Phys. 33 3174-82
    • (2006) Med. Phys. , vol.33 , Issue.9 , pp. 3174-3182
    • Parent, L.1    Seco, J.2    Evans, P.M.3    Dance, D.R.4    Fielding, A.5
  • 13
    • 0038811606 scopus 로고    scopus 로고
    • Random and systematic beam modulator errors in dynamic intensity modulated radiotherapy
    • Parsai H, Cho P S, Phillips M H, Giansiracusa R S and Axen D 2003 Random and systematic beam modulator errors in dynamic intensity modulated radiotherapy Phys. Med. Biol. 48 1109-21
    • (2003) Phys. Med. Biol. , vol.48 , Issue.9 , pp. 1109-1121
    • Parsai, H.1    Cho, P.S.2    Phillips, M.H.3    Giansiracusa, R.S.4    Axen, D.5
  • 14
    • 0031732429 scopus 로고    scopus 로고
    • Independent verification using portal imaging of intensity-modulated beam delivery by the dynamic MLC technique
    • Partridge M, Evans P M, Mosleh-Shirazi A and Convery D 1998 Independent verification using portal imaging of intensity-modulated beam delivery by the dynamic MLC technique Med. Phys. 25 1872-9
    • (1998) Med. Phys. , vol.25 , Issue.10 , pp. 1872-1879
    • Partridge, M.1    Evans, P.M.2    Mosleh-Shirazi, A.3    Convery, D.4
  • 15
    • 0033867804 scopus 로고    scopus 로고
    • Leaf position verification during dynamic beam delivery: A comparison of three applications using electronic portal imaging
    • Partridge M, Evans P M, van Herk M, Ploeger L S, Budgell G J and James H V 2000 Leaf position verification during dynamic beam delivery: a comparison of three applications using electronic portal imaging Med. Phys. 27 1601-9
    • (2000) Med. Phys. , vol.27 , Issue.7 , pp. 1601-1609
    • Partridge, M.1    Evans, P.M.2    Van Herk, M.3    Ploeger, L.S.4    Budgell, G.J.5    James, H.V.6
  • 17
    • 3042548119 scopus 로고    scopus 로고
    • An extensive log-file analysis of step-and-shoot intensity modulated radiation therapy segment delivery errors
    • Stell A M, Li J G, Zeidan O A and Dempsey J F 2004 An extensive log-file analysis of step-and-shoot intensity modulated radiation therapy segment delivery errors Med. Phys. 31 1593-602
    • (2004) Med. Phys. , vol.31 , Issue.6 , pp. 1593-1602
    • Stell, A.M.1    Li, J.G.2    Zeidan, O.A.3    Dempsey, J.F.4
  • 18
    • 0036735619 scopus 로고    scopus 로고
    • Fast and accurate leaf verification for dynamic multileaf collimation using an electronic portal imaging device
    • Vieira S C, Dirkx M L, Pasma K L and Heijmen B J 2002 Fast and accurate leaf verification for dynamic multileaf collimation using an electronic portal imaging device Med. Phys. 29 2034-40
    • (2002) Med. Phys. , vol.29 , Issue.9 , pp. 2034-2040
    • Vieira, S.C.1    Dirkx, M.L.2    Pasma, K.L.3    Heijmen, B.J.4
  • 19
    • 33746969105 scopus 로고    scopus 로고
    • Fast, daily linac verification for segmented IMRT using electronic portal imaging
    • Vieira S C, Bolt R A, Dirkx M L, Visser A G and Heijmen B J 2006 Fast, daily linac verification for segmented IMRT using electronic portal imaging Radiother. Oncol. 80 86-92
    • (2006) Radiother. Oncol. , vol.80 , Issue.1 , pp. 86-92
    • Vieira, S.C.1    Bolt, R.A.2    Dirkx, M.L.3    Visser, A.G.4    Heijmen, B.J.5
  • 20
    • 85024975778 scopus 로고    scopus 로고
    • Quality assurance devices for dynamic conformal radiotherapy
    • Wong V Y 2004 Quality assurance devices for dynamic conformal radiotherapy J. Appl. Clin. Med. Phys. 5 8-15
    • (2004) J. Appl. Clin. Med. Phys. , vol.5 , Issue.1 , pp. 8-15
    • Wong, V.Y.1
  • 21
    • 0034237722 scopus 로고    scopus 로고
    • Dosimetric effects of patient displacement and collimator and gantry angle misalignment on intensity modulated radiation therapy
    • Xing L, Lin Z, Donaldson S S, Le Q T, Tate D, Goffinet D R, Wolden S, Ma L and Boyer A L 2000 Dosimetric effects of patient displacement and collimator and gantry angle misalignment on intensity modulated radiation therapy Radiother. Oncol. 56 97-108
    • (2000) Radiother. Oncol. , vol.56 , Issue.1 , pp. 97-108
    • Xing, L.1    Lin, Z.2    Donaldson, S.S.3    Le Q, T.4    Tate, D.5    Goffinet, D.R.6    Wolden, S.7    Ma, L.8    Boyer, A.L.9
  • 22
    • 2342508979 scopus 로고    scopus 로고
    • Quantitative measurement of MLC leaf displacements using an electronic portal image device
    • Yang Y and Xing L 2004 Quantitative measurement of MLC leaf displacements using an electronic portal image device Phys. Med. Biol. 49 1521-33
    • (2004) Phys. Med. Biol. , vol.49 , Issue.8 , pp. 1521-1533
    • Yang, Y.1    Xing, L.2
  • 24
    • 0142057574 scopus 로고    scopus 로고
    • Dependence of fluence errors in dynamic IMRT on leaf-positional errors varying with time and leaf number
    • Zygmanski P, Kung J H, Jiang S B and Chin L 2003 Dependence of fluence errors in dynamic IMRT on leaf-positional errors varying with time and leaf number Med. Phys. 30 2736-49
    • (2003) Med. Phys. , vol.30 , Issue.10 , pp. 2736-2749
    • Zygmanski, P.1    Kung, J.H.2    Jiang, S.B.3    Chin, L.4
  • 25
    • 0035185056 scopus 로고    scopus 로고
    • Method of identifying dynamic multileaf collimator irradiation that is highly sensitive to a systematic MLC calibration error
    • Zygmanski P and Kung J H 2001 Method of identifying dynamic multileaf collimator irradiation that is highly sensitive to a systematic MLC calibration error Med. Phys. 28 2220-6
    • (2001) Med. Phys. , vol.28 , Issue.11 , pp. 2220-2226
    • Zygmanski, P.1    Kung, J.H.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.