메뉴 건너뛰기




Volumn 13, Issue 1, 2008, Pages 152-154

Aspiration pneumonia due to polyethylene glycol-electrolyte solution (Golytely) treated by bronchoalveolar lavage

Author keywords

ARDS; Aspiration pneumonia; BAL; Golytely

Indexed keywords

ELECTROLYTE; GOLYTELY;

EID: 38049146211     PISSN: 13237799     EISSN: 14401843     Source Type: Journal    
DOI: 10.1111/j.1440-1843.2007.01209.x     Document Type: Article
Times cited : (10)

References (15)
  • 1
    • 0018849738 scopus 로고
    • Development of a lavage solution associated with minimal water and electrolyte absorption or secretion
    • Davis GR, Santa Ana CA, Morawski SG, Fordtran JS. Development of a lavage solution associated with minimal water and electrolyte absorption or secretion. Gastroenterology 1980 78 : 991 5.
    • (1980) Gastroenterology , vol.78 , pp. 991-5
    • Davis, G.R.1    Santa Ana, C.A.2    Morawski, S.G.3    Fordtran, J.S.4
  • 2
    • 0011130509 scopus 로고    scopus 로고
    • Bowel preparation before colonoscopy. Choosing the best lavage regimen
    • Jr., 207. 12, 214.
    • Tooson JD, Gates LK Jr. Bowel preparation before colonoscopy. Choosing the best lavage regimen. Postgrad. Med. 1996 100 : 203 4, 207 12, 214.
    • (1996) Postgrad. Med. , vol.100 , pp. 203-4
    • Tooson, J.D.1    Gates, L.K.2
  • 3
    • 0020535645 scopus 로고
    • A randomized blinded clinical trial of a rapid colonic lavage solution (Golytely) compared with standard preparation for colonoscopy and barium enema
    • Ernstoff JJ, Howard DA, Marshall JB, Jumshyd A, McCullough AJ. A randomized blinded clinical trial of a rapid colonic lavage solution (Golytely) compared with standard preparation for colonoscopy and barium enema. Gastroenterology 1983 84 : 1512 16.
    • (1983) Gastroenterology , vol.84 , pp. 1512-16
    • Ernstoff, J.J.1    Howard, D.A.2    Marshall, J.B.3    Jumshyd, A.4    McCullough, A.J.5
  • 4
    • 0347296024 scopus 로고    scopus 로고
    • A randomized, blinded, prospective trial to compare the safety and efficacy of three bowel-cleansing solutions for colonoscopy (HSG-01*)
    • Ell C, Fischbach W, Keller R, Dehe M, Mayer G et al. A randomized, blinded, prospective trial to compare the safety and efficacy of three bowel-cleansing solutions for colonoscopy (HSG-01*). Endoscopy 2003 35 : 300 4.
    • (2003) Endoscopy , vol.35 , pp. 300-4
    • Ell, C.1    Fischbach, W.2    Keller, R.3    Dehe, M.4    Mayer, G.5
  • 5
    • 0027368437 scopus 로고
    • Esophageal perforation associated with polyethylene glycol electrolyte lavage solution
    • McBride MA, Vanagunas A. Esophageal perforation associated with polyethylene glycol electrolyte lavage solution. Gastrointest. Endosc. 1993 39 : 856 7.
    • (1993) Gastrointest. Endosc. , vol.39 , pp. 856-7
    • McBride, M.A.1    Vanagunas, A.2
  • 6
    • 0029397769 scopus 로고
    • Polyethylene glycol electrolyte lavage solution-induced Mallory-Weiss tear
    • Schwartz T. Polyethylene glycol electrolyte lavage solution-induced Mallory-Weiss tear. Gastroenterol. Nurs. 1995 18 : 233 4.
    • (1995) Gastroenterol. Nurs. , vol.18 , pp. 233-4
    • Schwartz, T.1
  • 7
    • 0029783670 scopus 로고    scopus 로고
    • Angioedema from oral polyethylene glycol electrolyte lavage solution
    • Stollman N, Manten HD. Angioedema from oral polyethylene glycol electrolyte lavage solution. Gastrointest. Endosc. 1996 44 : 209 10.
    • (1996) Gastrointest. Endosc. , vol.44 , pp. 209-10
    • Stollman, N.1    Manten, H.D.2
  • 8
    • 0025805091 scopus 로고
    • Probable anaphylactic reaction to polyethylene glycol electrolyte lavage solution
    • Schuman E, Balsam PE. Probable anaphylactic reaction to polyethylene glycol electrolyte lavage solution. Gastrointest. Endosc. 1991 37 : 411.
    • (1991) Gastrointest. Endosc. , vol.37 , pp. 411
    • Schuman, E.1    Balsam, P.E.2
  • 9
    • 0035058797 scopus 로고    scopus 로고
    • Life-threatening respiratory failure following accidental infusion of polyethylene glycol electrolyte solution into the lung
    • Narsinghani U, Chadha M, Farrar HC, Anand KS. Life-threatening respiratory failure following accidental infusion of polyethylene glycol electrolyte solution into the lung. J. Toxicol. Clin. Toxicol. 2001 39 : 105 7.
    • (2001) J. Toxicol. Clin. Toxicol. , vol.39 , pp. 105-7
    • Narsinghani, U.1    Chadha, M.2    Farrar, H.C.3    Anand, K.S.4
  • 10
    • 0036206089 scopus 로고    scopus 로고
    • Fulminant pulmonary oedema after administration of a balanced electrolyte polyethylene glycol solution
    • Argent A, Hatherill M, Reynolds L, Purves L. Fulminant pulmonary oedema after administration of a balanced electrolyte polyethylene glycol solution. Arch. Dis. Child. 2002 86 : 209.
    • (2002) Arch. Dis. Child. , vol.86 , pp. 209
    • Argent, A.1    Hatherill, M.2    Reynolds, L.3    Purves, L.4
  • 11
    • 0030097450 scopus 로고    scopus 로고
    • [acute respiratory distress syndrome with fatal outcome after inhalation of polyethylene glycol during preparation for colonoscopy]
    • Hastier P, Bellon S, Perrin C, Legall P, Chichmanian RM et al. [Acute respiratory distress syndrome with fatal outcome after inhalation of polyethylene glycol during preparation for colonoscopy]. Gastroenterol. Clin. Biol. 1996 20 : 216 17.
    • (1996) Gastroenterol. Clin. Biol. , vol.20 , pp. 216-17
    • Hastier, P.1    Bellon, S.2    Perrin, C.3    Legall, P.4    Chichmanian, R.M.5
  • 12
    • 0027448538 scopus 로고
    • Acute pulmonary edema after polyethylene glycol intestinal lavage in a child
    • Paap CM, Ehrlich R. Acute pulmonary edema after polyethylene glycol intestinal lavage in a child. Ann. Pharmacother. 1993 27 : 1044 7.
    • (1993) Ann. Pharmacother. , vol.27 , pp. 1044-7
    • Paap, C.M.1    Ehrlich, R.2
  • 13
    • 0036899907 scopus 로고    scopus 로고
    • Acute pulmonary oedema complicating polyethylene glycol intestinal lavage
    • Wong A, Briars GL. Acute pulmonary oedema complicating polyethylene glycol intestinal lavage. Arch. Dis. Child. 2002 87 : 537.
    • (2002) Arch. Dis. Child. , vol.87 , pp. 537
    • Wong, A.1    Briars, G.L.2
  • 15
    • 0031809016 scopus 로고    scopus 로고
    • Life-threatening complications of nasogastric administration of polyethylene glycol-electrolyte solutions (Golytely) for bowel cleansing
    • Marschall HU, Bartels F. Life-threatening complications of nasogastric administration of polyethylene glycol-electrolyte solutions (Golytely) for bowel cleansing. Gastrointest. Endosc. 1998 47 : 408 10.
    • (1998) Gastrointest. Endosc. , vol.47 , pp. 408-10
    • Marschall, H.U.1    Bartels, F.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.