메뉴 건너뛰기




Volumn 70, Issue 7, 2007, Pages 946-951

Efficacy of reduced-dose sirolimus-eluting stents in the human coronary artery: Serial IVUS analysis of neointimal hyperplasia and luminal dimension

Author keywords

Coronary artery disease; Drug eluting stent; IVUS; Restenosis

Indexed keywords

ACETYLSALICYLIC ACID; CLOPIDOGREL; RAPAMYCIN;

EID: 38049079892     PISSN: 15221946     EISSN: 1522726X     Source Type: Journal    
DOI: 10.1002/ccd.21272     Document Type: Article
Times cited : (14)

References (23)
  • 2
    • 10744222911 scopus 로고    scopus 로고
    • Analysis of 1-year clinical outcomes in the SIRIUS trial: A randomized trial of a sirolimus-eluting stent versus a standard stent in patients at high risk for coronary restenosis
    • Holmes DR Jr, Leon MB, Moses JW, Popma JJ, Cutlip D, Fitzgerald PJ, Brown C, Fischell T, Wong SC, Midei M, et al. Analysis of 1-year clinical outcomes in the SIRIUS trial: A randomized trial of a sirolimus-eluting stent versus a standard stent in patients at high risk for coronary restenosis. Circulation 2004;109:634-640.
    • (2004) Circulation , vol.109 , pp. 634-640
    • Holmes Jr, D.R.1    Leon, M.B.2    Moses, J.W.3    Popma, J.J.4    Cutlip, D.5    Fitzgerald, P.J.6    Brown, C.7    Fischell, T.8    Wong, S.C.9    Midei, M.10
  • 4
    • 0042388295 scopus 로고    scopus 로고
    • Randomized study to assess the effectiveness of slow- and moderate-release polymer-based paclitaxel-eluting stents for coronary artery lesions
    • Colombo A, Drzewiecki J, Banning A, Grube E, Hauptmann K, Silber S, Dudek D, Fort S, Schiele F, Zmudka K, et al. Randomized study to assess the effectiveness of slow- and moderate-release polymer-based paclitaxel-eluting stents for coronary artery lesions. Circulation 2003;108:788-794.
    • (2003) Circulation , vol.108 , pp. 788-794
    • Colombo, A.1    Drzewiecki, J.2    Banning, A.3    Grube, E.4    Hauptmann, K.5    Silber, S.6    Dudek, D.7    Fort, S.8    Schiele, F.9    Zmudka, K.10
  • 7
    • 0141885290 scopus 로고    scopus 로고
    • Pathological mechanisms of fatal late coronary stent thrombosis in humans
    • Farb A, Burke AP, Kolodgie FD, Virmani R. Pathological mechanisms of fatal late coronary stent thrombosis in humans. Circulation 2003;108:1701-1706.
    • (2003) Circulation , vol.108 , pp. 1701-1706
    • Farb, A.1    Burke, A.P.2    Kolodgie, F.D.3    Virmani, R.4
  • 12
    • 0035312809 scopus 로고    scopus 로고
    • american college of cardiology clinical expert consensus document on standards for acquisition, measurement and reporting of intravascular ultrasound studies (IVUS). A report of the American College of Cardiology Task Force on Clinical Expert Consensus Documents
    • Mintz GS, Nissen SE, Anderson WD, Bailey SR, Erbel R, Fitzgerald PJ, Pinto FJ, Rosenfield K, Siegel RJ, Tuzcu EM, et al. american college of cardiology clinical expert consensus document on standards for acquisition, measurement and reporting of intravascular ultrasound studies (IVUS). A report of the American College of Cardiology Task Force on Clinical Expert Consensus Documents. J Am Coll Cardiol 2001;37:1478-1492.
    • (2001) J Am Coll Cardiol , vol.37 , pp. 1478-1492
    • Mintz, G.S.1    Nissen, S.E.2    Anderson, W.D.3    Bailey, S.R.4    Erbel, R.5    Fitzgerald, P.J.6    Pinto, F.J.7    Rosenfield, K.8    Siegel, R.J.9    Tuzcu, E.M.10
  • 15
    • 0036787737 scopus 로고    scopus 로고
    • Background incidence of late malapposition after bare-metal stent implantation
    • Shah VM, Mintz GS, Apple S, Weissman NJ. Background incidence of late malapposition after bare-metal stent implantation. Circulation 2002;106:1753-1755.
    • (2002) Circulation , vol.106 , pp. 1753-1755
    • Shah, V.M.1    Mintz, G.S.2    Apple, S.3    Weissman, N.J.4
  • 16
    • 0037072467 scopus 로고    scopus 로고
    • Intravascular ultrasound findings in the multicenter, randomized, double-blind RAVEL (RAndomized study with the sirolimus-eluting VElocity balloon-expandable stent in the treatment of patients with de novo native coronary artery Lesions) trial
    • Serruys PW, Degertekin M, Tanabe K, Abizaid A, Sousa JE, Colombo A, Guagliumi G, Wijns W, Lindeboom WK, Ligthart J, et al. Intravascular ultrasound findings in the multicenter, randomized, double-blind RAVEL (RAndomized study with the sirolimus-eluting VElocity balloon-expandable stent in the treatment of patients with de novo native coronary artery Lesions) trial. Circulation 2002;106:798-803.
    • (2002) Circulation , vol.106 , pp. 798-803
    • Serruys, P.W.1    Degertekin, M.2    Tanabe, K.3    Abizaid, A.4    Sousa, J.E.5    Colombo, A.6    Guagliumi, G.7    Wijns, W.8    Lindeboom, W.K.9    Ligthart, J.10


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.